DAP INC -- 751 SEMI-GLOSS DARK RED (51719), DERUSTO RUST
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BYDSS
MSDS NAME: 751 SEMI-GLOSS DARK RED (51719), DERUSTO RUST(SUPDAT)
Responsible Party
Name: DAP INC
Box: 277
City: DAYTON OH 45401-0277
Info Phone: 513-667-4461
Emergency Phone Number: 800-543-3840
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DAP INC.
Box: 277
City: DAYTON OH 45401-0277
Phone: 513-253-7154/800-543-3840
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: YES
OSHA: NO
Effects of Exposure: ACUTE:ASPIR OF MATL INTO LUNGS DUE TO VOMIT CAN CAUSE CHEM
PNEUM, WHICH CAN BE FATAL. MAY IRRIT EYES, SKIN, NOSE & UPPER RESP TRACT,
HARMFUL IF INHALED. HARMFUL/FATAL IF SWALLOWED. IF INGESTED, THIS P ROD MAY
CAUSE VOMIT, DIARR & DEPRESSED RESP. INHAL MAY AFFECT BRAIN/NERV SYS
CAUSING HDCH, DIZZ/NAUS. (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: ZINC CHROMATE: IARC MONOGRAPHS, SUPPLEMENT, VOL
7, PG 165, 1987: GROUP 1.
Signs And Symptions Of Overexposure: HLTH HAZ:CHRONIC:RPTS HAVE ASSOC PERM
BRAIN & NERV SYS DMG W/PRLNG & RPTD OCCUP OVEREXP TO SOLVS.
PRLNG/RPTD CONT W/SKIN CAN CAUSE DEFAT, WHICH MAY LEAD TO DERM.
OVEREXP/MISUSE OF TOLUENE CAN CAUSE LI VER, KIDNEY & BRAIN DMG AS WELL AS
CARDIAC ABNORMS. ZINC CHROMATE DUST, WHEN INHALED, IS CONSIDERED KNOWN HUMAN
(SUPDAT)
Medical Cond Aggravated By Exposure: NONE KNOWN.
First Aid: EYE:FLUSH W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. CONTACT
MD IMMEDIATELY. SKIN:WASH IMMEDIATELY W/SOAP & WATER. INHAL:REMOVE TO
FRESH AIR. CONTACT MD IMMEDIATELY. INGEST:DO NOT INDUCE VOMITI NG.
IMMEDIATELY CONTACT MD OR REGIONAL POISON CONTROL CENTER FOR ADDITIONAL
TREATMENT.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: DIKE SPILL AREA. USE ABSORBENT MATERIAL OR SCRAPE UP
DRIED MATERIAL & PLACE INTO CONTAINERS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF ACCORDING TO FEDERAL, STATE & LOCAL
STANDARDS. USE ALL MATERIAL BEFORE DISPOSAL. IF MATERIAL CANNOT BE COMPLETELY
USED, RELIEVE PRESSURE IN CONTAINER UNTIL IT EQUALS EXTERNAL PRESSURE.
Handling And Storage Precautions: STORE AWAY FROM CAUSTICS & OXIDIZERS.
KEEP CONTAINERS TIGHTLY CLOSED WHEN NOT IN USE. KEEP OUT OF REACH OF
CHILDREN. DO NOT STORE AT TEMPS >120F.
Other Precautions: KEEP CONTAINERS FROM EXCESSIVE HEAT & FREEZING.
INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING & INHALING VAPORS MAY BE
HARMFUL OR FATAL.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: AEROSOL
Extinguishing Media: FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures: USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). COOL EXPOSED CONTAINERS W/WATER.
Unusual Fire/Explosion Hazard: CNTNRS MAY EXPLODE IF EXPOS TO EXTREME HEAT.
ELIMINATE SOURCE OF IGNITION:HEAT, ELEC EQUIP, SPARKS & OPEN FLAMES. DO
NOT PUT IN CONT W/OXIDIZING/CAUSTIC MATLS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: IF 8-HR EXPOS LIM/VALUE IS EXCEEDED FOR ANY COMPONENT,
USE NIOSH/MSHA APPRVD RESP. CONSULT YOUR SFTY EQUIP SUPPLIER & OSHA REG,
29CFR1910.134 FOR RESP REQUIREMENTS. USE NIOSH/MSHA APPRVD RESP IF SANDI NG
DRIED PAINT/DURING SPRAY APPLICATNS.
Ventilation: PROVIDE SUFFICIENT MECH VENT (LOC/GEN EXHST) TO MAINTAIN EXPOS
BELOW PEL & TLV. VAPS ARE HVR/AIR & WILL COLLECT
Protective Gloves: SOLVENT IMPERVIOUS GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: DELUGE SHOWER WHICH MEETS ANSI DESIGN CRITERIA (FP
N). PROVIDE EYEWASH & SOLV IMPERVIOUS APRON IF BODY CONT W/
Work Hygienic Practices: WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). MFR'S TRADE NAME/PART NO:PREVENTIVE ENAMEL
SPRAY. SPEC GRAV:0.73-0.75 (H*2O=1). EFTS OF OVEREXP:CARCIN BY IARC. RISK TO
ONE S HLTH DEPENDS UPON LEVEL & DURATION OFEXPOS. AVOID EXPOS TO MISTS
DURING SPRAY APPLICATIONS & DUST CREATED
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Density: >1
Spec Gravity: SUPP DATA
Evaporation Rate & Reference: >1 (N-BUTYL ACETATE=1)
Solubility in Water: NEGLIGIBLE
Appearance and Odor: OPAQUE LIQUID, VARIOUS COLORS; GASOLINE-LIKE ODOR.
Percent Volatiles by Volume: 85-88
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXCESSIVE HEAT & FREEZING.
Materials To Avoid: STRONG OXIDIZERS & CAUSTICS.
Hazardous Decomposition Products: NORMAL COMBUSTION PRODUCTS, I.E. CO*X, NO*X.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 751 SEMI-GLOSS DARK RED (51719), DERUSTO RUST(SUPDAT)
Company: DAP INC.
PO Box: 277
City: DAYTON OH
Zipcode: 45401-0277
Health Emergency Phone: 800-543-3840
Label Required IND: Y
Date Of Label Review: 07/12/1995
Status Code: C
Label Date: 07/12/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: FLAM AEROSOL.ACUTE:ASPIR OF MATL INTO LUNGS DUE TO
VOMIT CAN CAUSE CHEM PNEUM, CAN BE FATAL.MAY IRRIT EYE/SKIN/NOSE & UPPER
RESP TRACT, HARMFUL IF INHALED MAY AFFECT BRAIN/NERV SYS CAUSING HDCH, DIZZ/
NAUS.HARMFUL/FATAL IF SWALLOWED.INGESTED, THIS PROD MAY CAUSE VOMIT, DIARR
& DEPRESSED RESP.CHRONIC:CANCER HAZ:ZINC CHROMATE IS LISTED AS A
HUMAN/LUNG CARC(FPN).HAS MATL WHICH APPEARS ON NAVY OCCUP CH EM REPRO HAZS
LIST (FPN).RPTS HAVE ASSOC PERM BRAIN & NERV SYS DMG W/PRLNG & RPTD
OCCUP OVEREXP TO SOLVS.PRLNG/RPTD CONT W/SKIN CAN CAUSE DEFAT, LEADING TO
DERM.OVEREXP/MISUSE OF TOLUENE CAN CAUSE LIV ER, KIDNEY & BRAIN DMG AS
WELL AS CARDIAC ABNORMS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|