EI DUPONT DE NEMOURS & CO -- PI2525
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CDWWR
MSDS NAME: PI2525
Responsible Party
Name: EI DUPONT DE NEMOURS & CO
Address: ELECTRONICS DEPT
City: WILMINGTON DE 19898
Info Phone: 800-441-7515
Emergency Phone Number: 800-441-3637;800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: EI DUPONT DE NEMOURS & CO
Address: UNKNOWN
Box: UNKNOW
City: UNKNOWN NK 00000
Phone: UNKNOWN
Name: EI DUPONT DE NEMOURS CO/AUTOMOTIVE PRODS
Address: 1007 MARKET ST
City: WILMINGTON DE 19898
Phone: (800) 441-7515
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENT 1
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ING 1:TOX EFTS DESCRIBED IN ANIMALS INCL: SKIN/EYE
CNTCT:MOD EYE IRRIT; MILD SKIN IRRIT; NO SKIN SENSIT. INHAL: RESPIRATION RATE
CHGS; BLOOD SYS EFTS; WT LOSS; SALIVATION. TOX EFTS OF RPTD/PRLNGD ANIM AL
EXPOS INCL:INHAL: LETHARGY/INACTIVITY; RESPIRATION RATE CHGS; THYMUS EFTS;
BONE MARROW EFTS; SPLEEN (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:EFTS; LYMPH SYS EFTS; DEATH.
INGEST: ENZYME EFTS; BLOOD EFTS; BODY CHEM EFTS; THYROID EFTS. TOX EFTS OF
CHRONIC ANIMAL TESTS INCL: INHAL:REDUCED WT GAIN. HUMAN HLTH EFTS OF OVEREXP
MAY INCL: CNTCT W/LIQ/VAP: EYE IRRIT W/DISCOMFORT, TEARING/BLURRED VISION.
SKIN/EYE CNTCT: SKIN IRRIT W/DISCOMFORT/RASH. (SUPDAT)
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: SKIN: IMMED WASH SKIN W/SOAP & WATER. WASH CONTAMD CLTHG BEFORE
REUSE. EYES: IMMED FLUSH EYES W/PLENTY OF WATER FOR AT LEAST 15 MINUTES. CALL
MD. INHAL: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE ART IFICIAL
RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN. CALL MD. INGEST: DO NOT
INDUCE VOMITING. IMMED GIVE TWO GLASSES OF WATER. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON. CALL MD.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: FOR SMALL SPILLS, ABSORB ON RAGS, SAND OR OTHER
ABSORBENT MATERIAL. FOR LARGE SPILLS, GET WORKERS OUT OF AFFECTED AREA. IF
FLAM LIQS OR VAPS MAY BE PRESENT, TURN OFF ELEC DEVICES OR OTHER SOURCES OF S
PARKS OR FLAMES. WEAR PROT EQUIP. USE
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: COMPONENTS OF THIS PRODUCT MAY BE CONSIDERED HAZARDOUS.
CONSULT APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS FOR ALLOWABLE
DISPOSAL METHODS.
Handling And Storage Precautions: STORE PROD IN REFRIGERATED LOCATION (0-4F),
AWAY FROM SUNLIGHT OR UV LIGHT TO ENSURE PROD VISCOSITY STABILITY. EMPTY PROD
CNTNRS, CONTAMD
Other Precautions: ADDNL ENGINEERING CTLS, WORK PRACTICES & TRAINING MAY BE
REQD DEPENDING ON EXPOS LEVELS. THESE ARE DISCUSSED IN OSHA RESP PROT STD (29
CFR 1910.134) & OSHA HAZ COMMUNICATION STD (29 CFR 1910.1200). VO LAT
SOLVS START EVAPORATING
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point Text: 194F,90C
Extinguishing Media: WATER SPRAY, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures: USE NIOSH APPRVD SCBA & FULL PROTECTIVE EQUIPMENT
(FP N). TOXIC DECOMP PRODS MAY FORM UNDER FIRE CNDTNS. DISPOSE OF RESIDUES
PER FEDERAL, STATE & LOCAL REG.
Unusual Fire/Explosion Hazard: THIS PRODUCT IS NOT AN UNUSUAL FIRE OR EXPLOSION
HAZARD.
=======================================================
Control Measures
=======================================================
Respiratory Protection: SELECTION OF SUITABLE RESP WILL DEPEND ON PROPERTIES OF
CONTAMINANT(S) & THEIR ACTUAL OR EXPECTED AIR CONC(S) VERSUS APPLIC LIMS.
CONSULT ANSI STD Z88.2 FOR DECISION LOGIC TO SELECT APPROP NIOSH APPRV D
RESPS. IF RESPS ARE NEEDED
Ventilation: ADEQ LOC VENT SHOULD BE USED TO KEEP EXPOS BELOW APPLIC LIMS.
OTHER ENGINEERING CTLS SUCH AS TOTALLY ENCLOSED
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). PROT
CLTHG SHOULD BE USED WHERE POSSIBILITY OF BODY CONTACT
Work Hygienic Practices: DO NOT SMOKE, CONSUME OR STORE FOOD/DRINKS IN AREAS
WHERE PROD IS HANDLED/STORED. AFTER HNDLG PROD, WASH HANDS
Supplemental Safety and Health: USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EFTS OF OVEREXP: BY INHAL: IRRIT OF UPPER RESP
PASSAGES W/COUGH & DISCOMFORT. HUMAN EFTS OF HIGHER LEVEL ACUTE, RPTD OR
CHRONIC OVEREXP MAY INCL: BY SKIN/EYE CNTCT: DERM. IN ADDN THERE ARE
INCONCLUSIVE OR UNVERIFIED RPTS OF HUMAN SENSIT.
=======================================================
Physical/Chemical Properties
=======================================================
Solubility in Water: SLIGHT
Appearance and Odor: COLORLESS TO AMBER VISCOUS LIQUID; AROMATIC ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: AVOID CONTACT WITH REDUCING AGENTS, OXIDIZING AGENTS,
BASES, ACIDS.
Hazardous Decomposition Products: DECOMPOSITION PRODUCTS AT HIGH TEMPERATURE
MAY INCLUDE CARBON MONOXIDE, CARBON DIOXIDE, WATER, NITROGEN OXIDES.
Hazardous Polymerization Indicator: YES
Conditions To Avoid Polymerization: MAY POLYM ENDOTHERMICALLY IF EXPOSED TO
TEMP OVER 90F, UV LIGHT OR FREE RADICAL INITIATORS. THIS MAY INCREASE
VISCOSITY.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PI2525
Assigned IND: Y
Company: EI DUPONT DE NEMOURS CO/AUTOMOTIVE PRODS
Street: 1007 MARKET ST
City: WILMINGTON DE
Zipcode: 19898
Health Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 06/11/1997
Status Code: C
Label Date: 06/11/1997
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Moderate
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: ACUTE: EYE CONTACT: IRRITATION, DISCOMFORT, TEARING AND
BLURRED VISION. SKIN CONTACT: IRRITATION, DISCOMFORT OR RASH. INHALATION:
UPPER RESPIRATORY TRACT IRRITATION, COUGHING AND DISCOMFORT. CHRONIC:
DERMATITIS. SENSITIZATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.