LIFE TECHNOLOGIES (FORMERLY GI -- 15523 AMMONIUM PERSULFATE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGJBH
MSDS NAME: 15523 AMMONIUM PERSULFATE
Responsible Party
Name: LIFE TECHNOLOGIES INC (FORMERLY GIBCO LAB)
Address: 3175 STALEY RD
City: GRAND ISLAND NY 14072-5000
Info Phone: 716-774-6700/800-828-6686
Emergency Phone Number: 716-774-6700/800-828-6686
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: LIFE TECHNOLOGIES INC (FORMERLY GIBCO LAB)
Address: 3175 STALEY RD
City: GRAND ISLAND NY 14072-5000
=======================================================
Contractor Summary
=======================================================
Name: LIFE TECHNOLOGIES INC (FORMERLY GIBCO LAB)
Address: 3175 STALEY RD
City: GRAND ISLAND NY 14072-5000
Phone: 716-774-6700/800-828-6686
=======================================================
Ingredients
=======================================================
Cas: 7727-54-0
RTECS #: SE0350000
Name: AMMONIUM PERSULFATE
% Wt: >98
ACGIH TLV: 2 MG/CUM
------------------------------
Name: NON-HAZARDOUS INGREDIENTS
% Wt: <2
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50(RAT): 820 MG/KG
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYES: MAY CAUSE CORNEAL ULCERATION. SKIN: MAY CAUSE
ALLERGIC DERMATOSES. INHALATION: MAY CAUSE NASAL, RESPIRATORY TRACT
IRRITATION/DESTRUCTION OF THE MUCOUS MEMBRANES. INGESTION: MAY CAUSE
SENSITIZATI ON & GI ULCERATION.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: LACRIMATION, TEARING, SWELLING, PAIN,
IRRITATION, HEADACHE, VOMITING, NAUSEA, DIARRHEA, ACNE, INTOXICATION.
Medical Cond Aggravated By Exposure: ALLERGY/HYPERSENSITIVITY TO SULFATES.
First Aid: EYES: FLUSH W/WATER FOR 15 MINS. SKIN: USE A DELUGE SAFETY SHOWER
FOR 5 MINS. INHALATION: REMOVE TO FRESH AIR. MONITOR CONTINUOUSLY FOR
RESPIRATORY DISTRESS. INGESTION: GIVE PLENTY OF WATER, IF CONSCI OUS. NOTES
TO PHYSICIAN: NO SPECIFIC ANTIDOTE. TREAT SYMPTOMATICALLY. OBTAIN MEDICAL
ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE/SHUT OFF IGNITION SOURCES. FLUSH AREA W/WATER.
DON'T USE ABSORBENTS CONTAINING CELLULOSIC/OTHER ORGANIC MATERIAL.
SHOVEL/SCOOP UP. DEPOSIT IN APPROPRIATE CONTAINERS FOR REMOVAL &
DISPOSAL.
Waste Disposal Methods: MAY BE INCINERATED IN A HAZARDOUS WASTE INCINERATOR
IAW/FEDERAL, STATE & LOCAL REGULATIONS. KEEP IN SEALED CONTAINER BETWEEN
USE & FINAL DISPOSAL. UN1444.
Handling And Storage Precautions: STORE AT AMBIENT TEMPS: 59-95F. STORE IN DRY
AREA. KEEP CONTAINER TIGHTLY SEALED. KEEP AWAY FROM HEAT, IGNITION SOURCES.
AVOID PROLONGED STORAGE.
Other Precautions: AVOID GENERATING DUST. AVOID EYE/SKIN CONTACT. STORE AWAY
FROM INCOMPATIBLES. USE IN MINIMAL AMOUNTS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: FLOOD W/WATER.
Fire Fighting Procedures: STANDARD TURNOUT GEAR SLICKER SUIT (BUNKER GEAR). USE
POSITIVE PRESSURE SCBA.
Unusual Fire/Explosion Hazard: NON-COMBUSTIBLE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: AIR PURIFYING RESPIRATOR CANISTERS/CARTRIDGES: DUST,
FUMES & MISTS (RED/GRAY STRIPE ANSI COLOR CODE, NIOSH APPROVED).
Ventilation: LABORATORY EXHAUST HOOD/LOCAL EXHAUST.
Protective Gloves: NEOPRENE RUBBER
Eye Protection: SAFETY GLASSES
Other Protective Equipment: ANY WATERPROOF/RUBBER MATERIAL.
Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
HAND WASHING IS RECOMMENDED.
=======================================================
Physical/Chemical Properties
=======================================================
M.P/F.P Text: 248F
Spec Gravity: 1.982
Solubility in Water: 79
Appearance and Odor: WHITE/LIGHT STRAW COLORED CRYSTALS W/SLIGHT ACRID ODOR
Percent Volatiles by Volume: 0
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HEAT, MOISTURE.
Materials To Avoid: ORGANIC MATERIALS, ACIDS/BASES, REDUCING AGENTS, MOST
METALS, SODIUM PEROXIDE.
Hazardous Decomposition Products: THERMAL: OXYGEN GAS, SULFUR OXIDES, AMMONIA,
OXIDES OF NITROGEN.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 15523 AMMONIUM PERSULFATE
Company: LIFE TECHNOLOGIES INC (FORMERLY GIBCO LAB)
Street: 3175 STALEY RD
City: GRAND ISLAND NY
Zipcode: 14072-5000
Health Emergency Phone: 716-774-6700/800-828-6686
Label Required IND: Y
Date Of Label Review: 10/12/1999
Status Code: A
Origination Code: G
Hazard And Precautions: EYES: MAY CAUSE CORNEAL ULCERATION. SKIN: MAY CAUSE
ALLERGIC DERMATOSES. INHALATION: MAY CAUSE NASAL, RESPIRATORY TRACT
IRRITATION/DESTRUCTION OF THE MUCOUS MEMBRANES. INGESTION: MAY CAUSE
SENSITIZATI ON & GI ULCERATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|
ALL PAGES On Chemical Property IN THIS GROUP
| NAME | CAS |
SRS SURFACE RENEWAL SYSTEM ONE, 82733
| 25068-38-6 17557-23-2 1344-28-1 68919-79-9 68683-29-4 111-40-0 68610-56-0 98-00-0 80-05-7 7631-86-9 |
ACIDITY 0.500N, 14330
| 7664-93-9 7732-18-5 |
01-D0301-000, PROFESSIONAL LYSOL BRAND (SUPDAT)
| 112-34-5 75-28-5 |
3206 HAND UP
| |
2 CYCLE OIL TC-W3, CPS 226477
| |
BALLOTINI IMPACT BEADS
| 65997-17-3 |
PHOTOFINISH
| |
PARABOND M-4273 COVE BASE
| |
POLYESTER PHENOLIC RESIN, 9637
| 64742-95-6 1330-20-7 100-41-4 64742-94-5 111-76-2 50-00-0 554-13-2 95-63-6 98-82-8 |
2% THORIATED TUNGSTEN ELECTRODES
| 7440-33-7 1314-20-1 |
HP C3965A-COLOR DEVELOPER
| |
HP C3967A-PRINT DRUM
| |
PYRALIN POLYIMIDE, PI2723
| |
C2203
| |
ELASO-WATER PROOF WHITE & PASTEL, 70-850/250
| 124-68-5 9016-45-9 64742-65-0 60676-86-0 107-21-1 26530-20-1 |
SAFETY ORANGE, PFS500S8055
| 2451-62-9 13463-67-7 |
FLAT BLACK, EFB534S0055
| 25036-25-3 1317-65-3 |
DEVTHANE 359 H B CONVERTER, DC359C0910
| 28182-81-2 1330-20-7 123-86-4 822-06-0 71-43-2 100-41-4 |
MARK - 370
| |
L-620
| |
62-3608-8530-5, SCOTCH-WELD 2216 B/A (SUPDAT)
| |
62-3608-8535-4, SCOTCH-WELD 2216 B/A (SUPDAT)
| |
62-3608-9530-4, SCOTCH-WELD 2216 B/A (SUPDAT)
| |
UNI-WELD SERIES, 2800
| 109-99-9 78-93-3 67-64-1 108-94-1 9002-86-2 |
UNI-WELD SERIES, 6200
| 109-99-9 78-93-3 67-64-1 108-94-1 9002-86-2 |
UNI-WELD SERIES, 6700
| 109-99-9 78-93-3 67-64-1 108-94-1 9002-86-2 |
UNI-WELD SERIES, 303
| 109-99-9 78-93-3 67-64-1 108-94-1 9002-86-2 |
UNI-WELD SERIES, 703
| 109-99-9 78-93-3 67-64-1 108-94-1 9002-86-2 |
ULTRA-HIDE LATEX FLAT HOUSE PAINT, 9518
| |
RUST LICK B, 73011-1 GAL
| 102-71-6 141-43-5 111-42-2 |
RUST LICK B, 73051-5 GAL
| 102-71-6 141-43-5 111-42-2 |
RUST LICK B, 73551-55 GAL
| 102-71-6 141-43-5 111-42-2 |
62-1357-2631-3, SCOTCH-GRIP 1357 HIGH (SUPDAT)
| 64742-88-7 67-64-1 9010-98-4 68611-24-5 78-93-3 110-54-3 108-88-3 |
GS-1
| |
RT-8 81138 DURO TM EXTEND R RUST TREATMENT
| 112945-52-5 7732-18-5 65045-76-3 7727-43-7 111-76-2 57-55-6 |
81139 DURO EXTEND RUST TREATMENT
| 7732-18-5 65045-76-3 7727-43-7 111-76-2 57-55-6 112945-52-5 |
81137 DURO EXTEND RUST TREATMENT
| 65045-76-3 7727-43-7 111-76-2 57-55-6 112945-52-5 7732-18-5 |
RT-12 82073 DURO TM EXTEND R RUST TREATMENT
| 7732-18-5 57-55-6 107-21-1 64-18-6 100-42-5 |
TINCTURE BENZOIN
| 119-53-9 |
COLORLINK DEVELOPER
| 7732-18-5 139-88-8 111-90-0 |
CHLORINE SOLUTION 50-75 MG/L
| 7782-50-5 7732-18-5 |
00042 FISHERBRAND ULTRASONIC CLEANING SOLUTION CONCENTRATE
| 68390-66-9 67-63-0 7732-18-5 |
PALACOS R
| |
PALACOS FLUSSIGKEIT/STERIL IN AMPULLEN
| 80-62-6 99-97-8 |
2820 SANITIZE H/H
| 68424-85-1 68424-95-3 |
PRECOAT BRACKET ADHESIVE/UNITEK
| 14808-60-7 1565-94-2 24448-20-2 7631-86-9 2530-85-0 |
15523 AMMONIUM PERSULFATE
| 7727-54-0 |
HYDROGEN PEROXIDE 3% SOLUTION
| 7722-84-1 |
21267 BUFFER REAGENT FOR PC HARDNESS ANALYZER
| 124-68-5 87-69-4 7732-18-5 |
3008/7542 SCOTCHBOND MULTIPURPOSE PRIMER
| 7732-18-5 868-77-9 |
|
|