KEYSTONE LUBRICANTS -- CS300, K6K261K
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BRZSG
MSDS NAME: CS300, K6K261K
Responsible Party
Name: KEYSTONE LUBRICANTS
Address: 5 NORTH STILES ST
City: LINDEN NJ 07036
Info Phone: 201-862-2500
Emergency Phone Number: 800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: KEYSTONE LUBRICANTS
Address: 5 N STILES ST
City: LINDEN (WAS IN KING OF PRUSSIA,PA) NJ 07036
Phone: 800-344-2241
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50:(ORAL) >5 G/KG.
Route Of Entry Inds - Inhalation: NO
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: HLTH STUDIES HAVE SHOWN THAT MANY PETRO HYDROCARBONS &
SYNTHETIC LUBRICANTS POSE POTNTL HUMAN HLTH RISKS WHICH VARY FROM PERS TO
PERS. AS PREC, EXPOS TO LIQS, VAPS, MISTS/FUMES SHOULD BE MINIMIZED. PR
LNG/RPTD SKIN CONT W/THIS PROD TENDS TOREMOVE SKIN OIL POSS LEADING TO IRRIT
& DERM; HOWEVER, BASED ON(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:HUMAN EXPER & AVAIL
TOXICOLOGICAL DATA, THIS PROD IS JUDGED TO BE NEITHER "CORR" NOR "IRRIT" BY
OSHA. PROD CONTACTING EYE MAY CAUSE IRRIT. PROD HAS LOW ORDER OF ORAL &
DERMAL TOX. POSS ASPIR HAZ. INDUCED VOMIT MAY CAUSE ASPIR OF PROD INTO
LUNGS. VAP PRESS IS VERY LOW. VAP INHAL UNDER AMBIENT CNDTN IS
Medical Cond Aggravated By Exposure: UNKNOWN.
First Aid: EYE:FLUSH W/CLEAR WATER FOR AT LST 15 MINS/UNTIL IRRIT SUBSIDES. IF
IRRIT PERSISTS, CALL MD. SKIN:REMOVE CONTAM CLTHG & WASH SKIN THORO
W/SOAP & WATER. INHAL:IF OVERCOME BY HOT PROD, IMMED REMOVE FROM EXPOS
& CALL MD. IF BRTHG IS IRREG/HASSTOPPED, START RESUSCITATION; ADMIN
OXYGEN IF AVAIL. IF OVEREXP TO OIL MIST, REMOVE FROM FURTHER EXPOS UNTIL
EXCESS OIL MIST CNDTN SUBSIDES. INGEST:DO
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: KEEP PROD OUT OF SEWERS & WATERCOURSES BY
DIKING/IMPOUNDING. ABSORB W/SAND OR INERT MATL. SWEEP/SCOOP UP & REMOVE.
PVNT SPREAD OF SPILL. ADVISE AUTHS IF PROD HAS ENTERED/MAY ENTER SEWERS,
WATERCOURSES /EXTENSIVE LAND AREAS. ASSURE CONFORMITY
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: CONSULT FEDERAL, STATE OR LOCAL AUTHORITIES FOR PROPER
DISPOSAL PROCEDURES. ASSURE CONFORMITY W/APPLICABLE DISPOSAL REGULATIONS.
DISPOSE OF ABSORBED MATERIAL AT APPROVED WASTE SITE OR FACILITY.
Handling And Storage Precautions: KEEP CNTNRS CLSD WHEN NOT IN USE. DO NOT
HANDLE NEAR HEAT, SPKS, FLAME/STRONG OXIDANTS. MINIMIZE BRTHG VAP,
MIST/FUMES. AVOID PRLNG/RPTD CONT W/SKIN.
Other Precautions: EMPTY CNTNRS RETAIN RESIDUE (LIQ/VAP) & CAN BE
DANGEROUS. DO NOT PRESSURIZE, WELD, CUT, BRAZE, SOLDER, DRILL, GRIND/EXPOSE
SUCH CNTNRS TO HEAT, FLAME, SPKS/OTHER SOURCES OF IGNIT. THEY MAY EXPLODE
& C AUSE INJURY/DEATH. DO NOT
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: 400F,204C
Extinguishing Media: FOAM, WATER SPRAY(FOG), DRY CHEM, CARBON DIOXIDE &
VAPORIZING LIQ TYPE EXTING AGENTS MAY ALL BE SUITABLE FOR (SUPDAT)
Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). WATER/FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE-EXPOS CNTNRS COOL.
WATER FROTH MAY BE USED TO
=======================================================
Control Measures
=======================================================
Respiratory Protection: NORMALLY NOT NEEDED AT AMBIENT TEMPS. USE NIOSH/MSHA
APPRVD SUPPLIED AIR RESP PROT IN CONFINED/ENCLSD SPACES, IF NEEDED. USE
NIOSH/MSHA APPRVD FILTER, DUST, FUME/MIST RESP TYPE UNDER MISTING CNDTNS. U
SE NIOSH/MSHA APPRVD CAN OR
Ventilation: ALWAYS MAINTAIN BELOW PELS. USE LOC EXHST TO CAPTURE VAP,
MIST/FUMES, IF NEC. PROVIDE >60 FT PER MIN HOOD FACE
Protective Gloves: CHEMICAL-RESISTANT GLOVES.
Eye Protection: USE SPLASH GOGGLES OR FACE SHIELD.
Other Protective Equipment: USE CHEM-RESIST APRON/OTHER IMPERVIOUS CLTHG, IF
NEEDED, TO AVOID CONTAM REGULAR CLTHG WHICH COULD RSLT IN PRLNG
Work Hygienic Practices: REMOVE CONTAM CLTHG, LAUNDER/DRY-CLEAN BEFORE REUSE.
REMOVE CONTAM SHOES & THORO CLEAN BEFORE REUSE; DISCARD IF
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EXTING MEDIA:EXTING FIRES INVOLVING THIS TYPE
PROD, DEPENDING ON SIZE/POTNTL SIZE OF FIRE & CIRCUMSTANCES RELATED TO
SITUAT ION. PLAN FIRE PROT & RESPONSE STRATEGYTHRU CONSULTATION W/LOC
FIRE PROT AUTHS/APPROP SPECIALISTS.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: V6
B.P. Text: WIDE RANGE
Vapor Pres: <0.1 @ 20C
Spec Gravity: <1 (H2O=1)
Solubility in Water: NEGLIGIBLE
Appearance and Odor: GREEN LIQUID; LOW ODOR.
Percent Volatiles by Volume: NEGLIG
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: AVOID CONT W/STRONG OXIDANTS SUCH AS LIQUID CHLORINE,
CONCENTRATED OXYGEN, SODIUM HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CS300, K6K261K
Company: KEYSTONE LUBRICANTS
Street: 5 N STILES ST
City: LINDEN (WAS IN KING OF PRUSSIA,PA) NJ
Zipcode: 07036
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 10/12/1993
Status Code: C
Label Date: 10/12/1993
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: AVOID EXPOSURE TO VAPORS, MIST & SPRAY.
ACUTE:IRRITATING TO SKIN & EYES. DERMATITIS. ASPIRATION HAZARD.
CHRONIC:NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|