BROWNE LABORATORIES INC -- DCM-16
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BTPWK
MSDS NAME: DCM-16
Responsible Party
Name: BROWNE LABORATORIES INC
Address: 4138 S CREEK RD
City: CHATTANOOGA TN 37406
Info Phone: 615-698-7777
Emergency Phone Number: 615-698-7777
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: BROWNE LABORATORIES INC
Address: 4138 SOUTH CREEK RD
City: CHATTANOOGA TN 37406-1021
Phone: 615-698-7777
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: EYE: CAUSES BURNS. SKIN: IRRITATES NOSE, THROAT,
AND SKIN. OTHER EFTS: NONE KNOWN.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: EYES: FLUSH THORO WITH WATER FOR AT LEAST 15 MINUTES. GET IMMED MED
ATTN. SKIN: IF DRENCHED, REMOVE CLOTHING UNDER SAFETY SHOWER AND FLOOD
EXPOSED AREAS WITH WATER. WASH CLOTHING BEFORE REUSE. SEE A P HYS IF IRRIT
OCCURS. INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O2/ARTF RESP) (FP N).
INGEST: CALL MD IMMED (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CONFINE SPILL TO MINIMIZE SPREAD. RECLAIM INTO DRUM
IF POSSIBLE, OTHERWISE, NEUTRALIZE WITH SODA ASH/LIME FOR PROPER DISPOSAL.
Neutralizing Agent: SODA ASH/LIME.
Waste Disposal Methods: I/A/W CURRENT FEDERAL, STATE, AND LOCAL REGULATIONS.
Handling And Storage Precautions: DO NOT GET IN EYES, ON SKIN/CLTHG. DO NOT
INGEST OR INHALE. KEEP CONTAINER CLOSED.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: WILL NOT BURN
Extinguishing Media: MEDIA SUITABLE FOR SURROUNDING FIRE (FP N).
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT (FP N). WATER SOLUTIONS ARE STRONG ACIDS.
Unusual Fire/Explosion Hazard: MAY RELEASE SO2, SO3, NH3 GASES IF INVOLVED IN
FIRE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N).
Ventilation: USE W/ADEQUATE VENTILATION.
Protective Gloves: BUTYL RUBBER GLOVES.
Eye Protection: FACESHIELD OR SPLASH GOGGLES.
Other Protective Equipment: EMERGENCY EYEWASH AND DELUGE SHOWER (FP N).
Work Hygienic Practices: WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health: BOILING POINT: 408F, 209C (DECOMPOSES). VAPOR
PRESSURE: 205C NEGLIG.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: C1
B.P. Text: SUPP DATA
Vapor Pres: SUPP DATA
PH: 1
Appearance and Odor: CLEAR LIQUID
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: DECOMPOSES W/HEAT TO REL SO2, SO3, AND NH3 GASES.
Hazardous Decomposition Products: HAZARDOUS REACTION IN AQUEOUS SOLUTION MAY
OCCUR WITH CHLORINE, HYPOCHLOROUS ACID.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: DCM-16
Company: BROWNE LABORATORIES INC
Street: 4138 SOUTH CREEK RD
City: CHATTANOOGA TN
Zipcode: 37406-1021
Health Emergency Phone: 615-698-7777
Label Required IND: Y
Date Of Label Review: 12/07/1993
Status Code: C
Label Date: 12/07/1993
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Severe
Fire Hazard: None
Reactivity Hazard: Slight
Hazard And Precautions: MAY PRODUCE HAZARDOUS DECOMPOSITION PRODUCTS. ACUTE:
EYE: CAUSES BURNS. SKIN: IRRITATES NOSE, THROAT, AND SKIN. CHRONIC: NONE
SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|