LOCTITE CORP AUTOMOTIVE & CONS -- PERMATEX(R) SILICONE FORM-A-GASKET(R)RTV BLUE
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 00-843-0802
MSDS Num: BVTZN
MSDS NAME: PERMATEX(R) SILICONE FORM-A-GASKET(R)RTV BLUE
Kit Part: Y
Responsible Party
Name: LOCTITE CORP AUTOMOTIVE & CONSUMER GROUP
Address: 4450 CRANWOOD PKY
City: CLEVELAND OH 44128-4004
Info Phone: 800-321-9188 OR 216-663-3614(FAX)
Emergency Phone Number: 216-663-3011
Preparer's Name: JEAN TOBBE
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: LOCTITE CORP AUTOMOTIVE AND CONSUMER GROUP
Address: 4450 CRANWOOD COURT
City: CLEVELAND OH 44128-4004
=======================================================
Contractor Summary
=======================================================
Name: LOCTITE CORP AUTOMOTIVE AND CONSUMER GROUP
Address: 4450 CRANWOOD COURT
City: CLEVELAND OH 44128-4004
Phone: 216-663-3011
=======================================================
Item Description Information
=======================================================
Item Manager: GSA
Item Name: ADHESIVE
Unit of Issue: KT
UI Container Qty: 0
=======================================================
Ingredients
=======================================================
Cas: 70131-67-8
Name: DIMETHYL POLYSILOXANE SILANOL
% Wt: 80-85
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
------------------------------
Cas: 17689-77-9
Name: ETHYLTRIACETOXYSILANE
% Wt: 1-3
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
------------------------------
Cas: 112945-52-5
Name: FUMEDD SILICA
% Wt: 10-15
Other REC Limits: NONE RECOMMENDED
OSHA PEL: NOT ESTABLISHED
ACGIH TLV: NOT ESTABLISHED
------------------------------
Cas: 4253-34-3
RTECS #: VV4500000
Name: METHYLTRIACETOXYSILANE
% Wt: 1-3
Other REC Limits: NONE RECOMMENDED
OSHA PEL: 10 PPM
ACGIH TLV: 10 PPM
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50 (RAT) IS UNKNOWN
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACETIC ACID LIBERATED DURING CURE IRRITATES EYES, NOSE,
& THROAT. PROLONGED OR REPEATED CONTACT MAY IRRITATE SKIN.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: EYE & SKIN IRRITATION MODERATE BY
INGESTION.
Medical Cond Aggravated By Exposure: NONE ESTABLISHED.
First Aid: INGESTION: DO NOT INDUCE VOMITING. CALL PHYSICIAN. INHALATION:
REMOVE TO FRESH AIR. CALL PHYSICIAN. SKIN: WASH THOROUGHLY WITH LARGE AMOUNTS
OF WATER. EYES: FLUSH WITH WATER FOR AT LEAST 15 MINS. CON SULT PHYSICIAN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: WIPE OR SCRAPE UP MATERIAL. MAINTAIN GOOD VENTILATION
FOR LARGE SPILLS. ALLOW MATERIAL TO CURE TO RUBBER.
Waste Disposal Methods: LANDFILL OR INCINERATE FOLLOWING EPA & LOCAL
REGULATIONS. MATERIAL NOT CONSIDERED A HAZARDOUS WASTE.
Handling And Storage Precautions: STORE IN DRY AREA BELOW 90F. KEEP CONTAINERS
CLOSED WHEN NOT IN USE. AVOID SKIN/EYE CONTACT. ACETIC ACID VAPOR RELEASED
DURING APPLICATION & CURE.
Other Precautions: DO NOT WEAR CONTACT LENSES WHILE APPLYING MATERIAL. VAPOR
MAY BE TRAPPED UNDER LENS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: CC
Flash Point Text: >200F,>93C
Extinguishing Media: CARBON DIOXIDE, FOAM.
Fire Fighting Procedures: NONE KNOWN.
Unusual Fire/Explosion Hazard: NONE KNOWN.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE SPECIFIED BY MANUFACTURER.
Ventilation: SUFFICIENT TO MAINTAIN VAPOR CONCENTRATION BELOW TLV IN CONFINED
AREA.
Protective Gloves: WEAR RUBBER OR PLASTIC GLOVES.
Eye Protection: WEAR SAFETY GLASSES OR GOGGLES.
Other Protective Equipment: NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices: WASH AFTER USING.
Supplemental Safety and Health: PART NUMBERS: 6BR, 6B, 6C.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: V7
B.P. Text: >300F,>149C
Vapor Pres: <5MM
Spec Gravity: 1.04
Appearance and Odor: BLUE PASTE, ACETIC ACID ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: OXIDIZING MATERIALS.
Hazardous Decomposition Products: SILICON DIOXIDE, CARBON DIOXIDE, OTHER CARBON
PRODUCTS.
Hazardous Polymerization Indicator: YES
Conditions To Avoid Polymerization: AIR MOISTURE CAUSES POLYMERIZATION & ACETIC
ACID VAPORS ARE RELEASED.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
Transportation Information
=======================================================
Trans ID NO: 88338
MSDS NAME: PERMATEX(R) SILICONE FORM-A-GASKET(R)RTV BLUE
MSDS Prepared Date: 06/19/1992
Review Date: 11/21/1994
Net Unit Weight: UNKNOWN
AF MMAC Code: NR
Multiple KIT Number: 0
Kit Part IND: Y
Review IND: Y
Unit Of Issue: KT
Container QTY: 0
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PERMATEX(R) SILICONE FORM-A-GASKET(R)RTV BLUE
Company: LOCTITE CORP AUTOMOTIVE AND CONSUMER GROUP
Street: 4450 CRANWOOD COURT
City: CLEVELAND OH
Zipcode: 44128-4004
Health Emergency Phone: 216-663-3011
Label Required IND: Y
Date Of Label Review: 11/21/1994
Status Code: C
Label Date: 11/21/1994
Origination Code: F
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: Slight
Hazard And Precautions: ACETIC ACID LIBERATED DURING CURE IRRITATES EYES, NOSE,
& THROAT. PROLONGED OR REPEATED CONTACT MAY IRRITATE EYES. INGESTION:
MODERATELY TOXIC. TARGET ORGANS: SKIN, EYES, RESPIRATORY & DIGESTIVE
TRACT S. TARGET ORGANS: EYES, SKIN, CNS, KIDNEYS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.