mineral oil, petroleum distillates, acid-treated heavy naphthenic
LUBRICATING SPECIALTIES CO -- G0450 MOREYS RED SUPER PREMIUM GREASE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWWCN
MSDS NAME: G0450 MOREYS RED SUPER PREMIUM GREASE
Responsible Party
Name: LUBRICATING SPECIALTIES CO
Address: 8015 PARAMOUNT BLVD
City: PICO RIVERA CA 90660-4811
Info Phone: 213-928-3311
Emergency Phone Number: 213-928-3311
Preparer's Name: RICHARD J EBERHARDT
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: TECHNOLUBE PRODUCT COMPANY
Address: 8015 PARAMOUNT BLVD.
City: PICO RIVERA CA 90660-4811
=======================================================
Contractor Summary
=======================================================
Name: TECHNOLUBE PRODUCT COMPANY
Address: 8015 PARAMOUNT BLVD.
City: PICO RIVERA CA 90660-4811
Phone: 562 776-4000 GEN: 562-776-4000
=======================================================
Ingredients
=======================================================
Cas: 64742-18-3
RTECS #: PY8032000
Name: MINERAL OIL, PETROLEUM DISTILLATES, ACID-TREATED HEAVY NAPHTHENIC
% Wt: <90
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: SKIN: PROLONGED/REPEATED CONTACT MAY PRODUCE MILD
IRRITATION & INFLAMMATION.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: IRRITATION, INFLAMMATION.
First Aid: INGESTION: DON'T INDUCE VOMITING. INHALATION: REMOVE TO FRESH AIR.
GIVE CPR IF NEEDED. EYES: FLUSH W/COPIOUS AMOUNTS OF WATER. SKIN: WASH W/SOAP
& WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: STOP FLOW. WIPE/MOP UP/ABSORB W/DIATOMACEOUS
EARTH/OTHER INERT MATERIAL. STORE IN APPROPRIATE CONTAINER FOR DISPOSAL.
Waste Disposal Methods: DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.
Handling And Storage Precautions: AVOID STORAGE NEAR OPEN FLAME/OTHER SOURCES
OF IGNITION. PROPER FOOTWEAR REQUIRED.
Other Precautions: EXCESSIVE MISTING MAY CAUSE SLIPPERY FLOORS. WASH/TAKE
SHOWER IF GENERAL CONTACT OCCURS.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: >482F
Extinguishing Media: CO2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures: DON'T ENTER ANY ENCLOSED/CONFINED AREA W/OUT PROPER
PROTECTIVE EQUIPMENT & SCBA.
Unusual Fire/Explosion Hazard: SLIGHTLY COMBUSTIBLE. WHEN HEATED > FLASH
POINT WILL RELEASE FLAMMABLE VAPORS & BURN IN OPEN/BE EXPLOSIVE IN
CONFINED SPACES IF EXPOSED TO SOURCES OF IGNITION.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE NORMALLY REQUIRED
Ventilation: SUFFICIENT TO MAINTAIN ATMOSPHERE < TLV LIMIT
Protective Gloves: RECOMMENDED
Eye Protection: REQUIRED
Other Protective Equipment: CHEMICALLY RESISTANT BOOTS & APRONS.
Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
WASH HANDS W/SOAP & WATER BEFORE EATING/DRINKING/SMOKING.
Supplemental Safety and Health: DISCARD CONTAMINATED LEATHER GLOVES &
SHOES.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >662F
Vapor Pres: <0.01
Vapor Density: >1
Spec Gravity: 0.94
Solubility in Water: NEGLIGIBLE
Appearance and Odor: GREEN STRINGY GREASE W/PETROLEUM ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: TEMP >482F, OPEN FLAME, SOURCES OF IGNITION.
Materials To Avoid: STRONG OXIDIZING AGENTS
Hazardous Decomposition Products: CO & ASPHYXIANTS
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: G0450 MOREYS RED SUPER PREMIUM GREASE
Company: TECHNOLUBE PRODUCT COMPANY
Street: 8015 PARAMOUNT BLVD.
City: PICO RIVERA CA
Zipcode: 90660-4811
Health Emergency Phone: 213-928-3311
Label Required IND: Y
Date Of Label Review: 12/16/1998
Status Code: C
Label Date: 12/16/1998
Origination Code: G
Hazard And Precautions: SKIN: PROLONGED/REPEATED CONTACT MAY PRODUCE MILD
IRRITATION & INFLAMMATION.
IRRITATION, INFLAMMATION.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.