LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE EXPECTED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:EYES/SKIN:CAUSES IRRITATION. INGEST:NOT
CONSIDERED TOXIC.
Medical Cond Aggravated by Exposure:NOT KNOWN.
======================= First Aid Measures =======================
Eyes:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:FLUSH
W/WATER FOR 5 MINUTES. INGEST:DO NOT INDUCE VOMITING. GET MD.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:WATER, FOAM, DRY CHEMICAL OR CARBON DIOXIDE FOR
FIRES IN STORAGE AREA.
Fire Fighting Procedures:KEEP CONTAINER COOL WITH WATER SPRAY. WEAR
NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
Spill Release Procedures:NEUTRALIZE SPILLED MATERIAL W/LIME OR SODA
ASH. SQUEEGEE & COLLECT OR VACUUM SPILLAGE & PLACE IN CONTAINER FOR
DISPOSAL. FLUSH SPILL AREA W/WATER.
Neutralizing Agent:LIME OR SODA ASH.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, PROTECTED LOCATION.
KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:CLEAN UP SPILLS IMMEDIATELY. RINSE CONTAINER BEFORE
REUSE OR DISPOSAL.
Respiratory Protection:NOT NORMALLY REQUIRED.
Ventilation:LOCAL EXHAUST NOT NORMALLY REQUIRED. MECHANICAL EXHAUST NOT
NORMALLY REQUIRED EXCEPT IF APPLICABLE TLV IS EXCEEDED.
Protective Gloves:RUBBER OR PLASTIC RECOMMENDED.
Eye Protection:CHEM WORKERS GOGGLES.
Other Protective Equipment:EYE WASH STATION. PROTECTIVE CLOTHING
RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods:DISPOSE OF AT APPROVED CHEMICAL WASTE
REPROCESSING FACILITY. SMALL QUANTITIES MAY BE DISPOSED OF IN
SANITARY SEWER AFTER NEUTRALIZATION. DISPOSE I/A/W FEDERAL, STATE
AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their