Effects of Overexposure:ANAESTHETIC EFFECTS,DIZZINESS,HEADACHE.
======================= First Aid Measures =======================
First Aid:REMOVE TO FRESH AIR & OBTAIN DR. ATTENTION.ARTIFICIAL
RESPIRATION IF BREATHING HAS STOPPED.EYE CONTACT:FLUSH
W/WATER;CONSULT DR. INGEST:IF CONSCIOUS,INDUCE VOMITING,OBTAIN DR.
ATTN.
===================== Fire Fighting Measures =====================
Extinguishing Media:DRY POWDERS,CO*2 OR FOAM
Fire Fighting Procedures:USE CANISTER TYPE GAS MASKS IF PRODUCT IS
DECOMPOSING.
Unusual Fire/Explosion Hazard:COMBUSTION PRODUCTS CONTAIN HCL.
Spill Release Procedures:VENTILATE THE AREA; AVOID EXCESSIVE INHALATION
OF VAPORS.REMOVE CLOTHING WET WITH PHENOLENE 643 IMMEDIATELY & WASH
THE AFFECTED AREA WITH SOAP & WATER.REMOVE SPILLAGE BY MOPPING OR
ABSORBING.REMOVE RE SIDUE TO OUTDOOR UNOCCUPIED AREA.
====================== Handling and Storage ======================
Handling and Storage Precautions:FLOOR LEVEL VENTILATION.AVOID CONTACT
WITH SKIN,EYES & CLOTHING.DO NOT STORE NEAR DIRECT HEAT.VENT FROM
INDOOR TANKS SHOULD TERMINATE OUTDOORS.
Other Precautions:VENT OFF POSSIBLE INTERNAL PRESSURE BY SLOWLY OPENING
DRUM BUNG.KEEP FACE AWAY WHEN OPENING.VENT IN TANKS FOR FILLING &
BREATHING LOSSES.AVOID PROLONGED BREATHING OF VAPORS.READ DRUM
LAGE.
Respiratory Protection:NONE UNDER NORMAL USE.
Ventilation:LOCAL EXHAUST FOR FLOOR LEVEL VENTILATION & MECHANICAL
Protective Gloves:NEOPRENE OR PVC
Eye Protection:CHEMICAL SAFETY GLASSES.
Supplemental Safety and Health
HCC:T4
Boiling Pt:B.P. Text:162F
Vapor Pres:144
Vapor Density:4.5
Spec Gravity:1.335
Evaporation Rate & Reference:2.6,ETHER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID,ODOR OF CHLORINATED SOLVENT.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CORRODES ALUMINUM & AL ALLOYS;SOFTEN RUBBER;SOFTEN PLASTICS.
Stability Condition to Avoid:DO NOT HEAT.
Hazardous Decomposition Products:HCL IN THE EVENT OF FIRE, POSSIBLY
PHOSGENE,CHLORIDE FUMES.
Waste Disposal Methods:RECLAMATION IF FEASIBLE.OBTAIN SERVICES OF A
LICENSED DISPOSAL CO. PER THE RCRA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.