ing 10:heat and/or uv radiation may cause the formation of vent:proves inadequate to maintain safe vapor conc, ing 12:precautions, such as respiratory protection, may be supp data:pers until medical asst can be rendered. if brthg ing 14: md immediately . hexane (n-hexane) isopropyl alcohol ethane, 1,1,1-trichloro-; (1,1,1-trichloroethane) methane, dichloro-; (methylene chloride) petroleum gas (liquified); (propellant, aeropress 70, spill proc:keep out of drains, sewers/waterways.consult ing 6: call spill response teams if large spill. other prec:(vapor, liquid, and/or solid), all haz prec ing 8:pressure. toxic. avoid prlngd/rptd vapor brthg. avoid ing 9:no smoking in area of use. do not use in the general
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:PROD MAY BE EYE IRRITANT.
SKIN:PRLNGD/ RPTD SKIN CONT MAY RESULT IN DERMAT. ABSORBED THRU
SKIN. SYSTEMIC EFTS: VARIOUS STUDIES HAVE SHOWN POSS ASSOC W/EXPOS
TO PROD & FOLLOWING: LUNG, LIVER, KIDNE Y & BRAIN DMG IN LAB
ANIMALS. MAY CAUSECARDIAC ABNORMALITIES. CNS DEPRESSANT IN HIGH
CONC, RANGING FROM (EFTS OF OVEREX
Explanation of Carcinogenicity:METHYLENE CHLORIDE: GROUP 2B (IARC);
GROUP 2 (NTP).
Effects of Overexposure:HLTH HAZ:LIGHT-HEADEDNESS TO UNCON TO DEATH.
CAUSES BLOOD DMG. ASPHY ABOVE TLV. CHLOROCARBON MATLS HAVE PRODUCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A
SIMILAR EFT IN HUMANS . ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS (SUPP
DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:IF PROD COMES IN CONT W/EYES, GENTLY FLUSH W/LRG QTYS OF
WATER FOR AT LEAST 15 MIN & CALL MD IMMED.SKIN:IF PROD COMES IN
CONT W/SKIN, REMOVE CONTAM CLTHG & WASH W/QTYS OF WATER & CALL MD
IF IRRIT FROM CONT PERSISTS. INHAL:IF BRTHG DFCLT,
DIZZ/LIGHT-HEADEDNESS OCCUR WHEN WORKING IN AREAS W/HIGH VAP CONC,
VICTIM SHOULD SEEK AIR FREE OF VAPS.IF VICTIM EXPERIENCES CONTINUED
BRTHG DFCLT,(SUPP DATA)
===================== Fire Fighting Measures =====================
Flash Point:FLAMMABLE
Extinguishing Media:USE FOAM, CO2, OR DRY CHEMICAL FIRE FIGHTING
APPARATUS.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP .WATER MAY BE UNSUITABLE AS EXTING MEDIA, BUT
HELPFUL IN KEEPING ADJACENT CNTNRS (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP WORK AREAS FREE OF HOT METAL SURF &
OTHER SOURCES OF IGNIT. BLENDS CONTAINING CHLORINATED PRODS MAY
EXHIBIT REDUCED FLASH POINT AS THE MORE (SUPP DATA)
Spill Release Procedures:STAY UPWIND & AWAY FROM SPILL UNLESS WEARING
APPROP PROT EQUIP. STOP AND/OR CONTAIN DISCHARGE IF MAY BE DONE
SAFELY. KEEP ALL SOURCES OF IGNIT AWAY. VENT AREA OF SPILL. USE
NON-SPARKING TOOLS FOR CLEA NUP. COVER W/INERT MATL TO REDUCE
FUMES.(ING 6)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP PROD CNTNRS COOL, DRY & AWAY FROM
SOURCES OF IGNIT. USE & STORE THIS PROD W/ADEQ VENT. KEEP PRODUCT
CNTNRS CLSD WHEN NOT IN USE.
Other Precautions:PERS SHOULD AVOID INHAL OF VAPS. PERS CONT W/PROD
SHOULD BE AVOIDED. SHOULD CONT BE MADE, REMOVE SATURATED CLTHG &
FLUSH AFFECTED AREAS W/WATER. CNTNRS OF THIS MATL MAY BE HAZ WHEN
EMPTIED. SINCE EMPT IED CNTNRS RETAIN PROD RESIDUES (ING 8)
Respiratory Protection:THE USE OF RESP PROT DEPENDS ON VAPOR CONC ABOVE
TIME WEIGHTED TLV. USE A NIOSH/MSHA APPRVD RESP/GAS MASK
W/APPROPRIATE CARTRIDGES AND CANISTER, OR SUPPLIED AIR EQUIPMENT,
DEPENDING ON AIRBORNE CONC.
Ventilation:GENERAL MECH VENT MAY BE SUFF TO KEEP PROD VAP CONC WITHIN
SPECIFIED TIME-WEIGHTED TLV RANGES. IF GENERAL VENT (ING 12)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IMPERMEABLE APRONS ARE ADVISED WHEN WORKING
WITH THIS PROD. THE AVAILABILITY OF EYE WASHES AND SAFETY SHOWERS
IS REC.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:COOL. AVOID SPREADING BURNING LIQ W/WATER USED FOR
COOLING PURPOSES. EXPLO HAZ:VOLATILE CHLORINATE EVAP. THERM DECOMP
PRODS MAY INCLUDE HCL & PHOSGENE . EFTS OF OVEREXP:ACUTELY/C
HRONICALLY EXPSD TO CHLOROCARBONS . FIRST AID PROC:OXYGEN, WHERE
AVAIL, SHOULD BE ADMIN BY QUALIFIED (ING 14)
HCC:V3
Appearance and Odor:AEROSOL WITH SOLVENT ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZERS, ALUMINUM AND ZINC POWDERS.
Stability Condition to Avoid:DO NOT PUNCTURE OR INCINERATE CNTNR. DO
NOT EXPOSE TO HEAT, DIRECT SUNLIGHT, OR STORE ABOVE 120F.
Hazardous Decomposition Products:THERM DECOMP IN PRESENCE OF AIR MAY
YIELD CO AND/OR CO2, HYDROGEN CHLORIDE, PHOSGENE & CHLORINE.
Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH APPLICABLE
LOCAL, COUNTY, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.