MSDS NAME:4730 GRAY CHEMICAL RESISTANT URETHANE, PT A
NIIN:00N001017
MSDS Number: BCGWD
=== Responsible Party ===
Company:TENNANT COMPANY
Address:701 N LILAC DR
Box:1452
City:MINNEAPOLIS
State:MN
ZIP:55440-1452
Country:US
CAGE:D0218
=== Contractor Identification ===
Company:TENNANT CO
Address:701 N LILAC DR
Box:1452
City:MINNEAPOLIS
State:MN
ZIP:55440-1452
Country:US
Phone:612-540-1556/800-553-8033
CAGE:59500
Company:TENNANT COMPANY
CAGE:D0218
============= Composition/Information on Ingredients =============
Effects of Overexposure:INH:ANESTH,RESP TRACT IRRIT/ACUTE CNS DEPRESS
W/HDCH,DIZ,STAG,UNCON. SEV EYE IRRIT. SKIN IRRIT;DERM
======================= First Aid Measures =======================
First Aid:INH:REMOVE TO FRESH AIR.APPLY ARTIF RESP, IF NEC.KEEP WARM &
QUIET. CALL MD. SKIN:WASH W/SOAP & WATER. REMOVE CONTAM CLOTHING.
EYE:FLUSH IMMED W/COPIOUS QTY OF RUNNING WATER AT LEAST 15 MIN.
CONSULT M D.
===================== Fire Fighting Measures =====================
Flash Point:87F SCC
Extinguishing Media:NFPA CLASS B EXTING, DRY CHEM, CO*2,FOAM
Fire Fighting Procedures:USE WATER FOG TO COOL EXPOS CANS & PREVENT
PRESSURE BUILDUP
Unusual Fire/Explosion Hazard:KEEP CONTANERS TIGHTLY CLSD.KEEP FRM
IGNIT SOURCES.CLSD CANS MAY EXPLO FRM EXTRM HEAT.(SUPP DATA).
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. AVOID BREATHING
VAPORS. VENTILATE AREA. REMOVE W/ INERT ABSORBENT. SCRUB W/SOAP &
WATER. SEE SPECIAL PROTECTION INFO.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL,DRY PLACE.STORE LG QTY
IN BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA CLASS 1C
FLAMMABLE LIQUIDS.DO NOT TAKE INTERNALLY.
Other Precautions:AVOID PRLNG CNTCT W/SKIN;IMMED REMOVE CONTAM CLOTHES.
GROUND CONTAINER WHEN POURING. AVOID FREE FALL OF LIQ IN EXCESS OF
A FEW IN.
Respiratory Protection:NIOSH/MSHA APPRVD CHEM RESP FOR ORGANIC VAPORS
AS REQ'D
Ventilation:GEN DILTN OR LOC EXHST IN VOL & PATTERN TO KEEP BELOW TLV
Protective Gloves:RUBBER
Eye Protection:SAFETY EYEWEAR FOR SPLASH
Supplemental Safety and Health
DO NOT APPLY PRODUCT TO HOT SURFACES. PART A OF A TWO PART PRODUCT.
Waste Disposal Methods:MFR STATES DO NOT INCINERATE CLSD
CONTAINERS.DISPOSE IAW FED,STATE & LOCAL CODES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their