===================== Product Identification =====================
MSDS NAME:STRYPEEZE SEMI PASTE
NIIN:00N001149
MSDS Number: BCHDF
=== Responsible Party ===
Company:SAVOGRAN
Box:130
City:NORWOOD
State:MA
ZIP:02062
Country:US
Info Phone Num:617-762-5400
Emergency Phone Num:617-762-5400
CAGE:86885
=== Contractor Identification ===
Company:SAVOGRAN
Box:130
City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:617-762-5400
CAGE:86885
============= Composition/Information on Ingredients =============
Name:SPILL PROC:MOVEMENT AT FLOOR LEVEL. DO NOT RESTART PILOT
LIGHTS/OPERATE ELEC DEVICES OR OTHER SOURES OF SPARKS/ (ING 15)
RTECS #:9999999ZZ
Name:ING 14:FLAMES/HEAT UNTIL ALL VAPORS (ODORS) ARE GONE.
RTECS #:9999999ZZ
Name:WASTE DISP METH:BURN WIPING MATL W/SLUDGE IN APPRVD INCIN
OR BURY IN APPRVD LANDFILL. COMPLY W/ALL LOCAL/STATE/FED REGS.
RTECS #:9999999ZZ
Name:OTHER PREC:BE ADEQUATELY VENTD AT FLOOR LEVEL. PERS MUST
NOT ENTER ANY UNVENTD AREAS/TANKS/OTHER CONTRS UNLESS (ING 18)
RTECS #:9999999ZZ
Name:ING 17:NIOSH/MSHA APPRVD POS PRESS, SCBA W/FULL FACE PIECE
& SFTY HARNESS ARE USED & AN OBSERVER IS PRESENT TO (ING 19)
RTECS #:9999999ZZ
Name:ING 18:RENDER ASSIST. NOTE:OBSERVER MUST NOT ENTER HAZ AREA
AT ANY TIME. CLSD CONTRS MAY EXPLODE IF EXPOSED TO (ING 20)
RTECS #:9999999ZZ
Name:ING 19:EXTREME HEAT. NEVER USE INTERNAL GAS/AIR PRESS TO
REMOVE CONTENTS FROM CONTR. EMPTIED CONTRS MAY RETAIN (ING 21)
RTECS #:9999999ZZ
Name:ING 20:PROD RESIDUES. ALL PRECS GIVEN MUST BE OBSERVED
UNTIL CONTRS IS THORO CLEANED/DESTROYED. ALL CONTRS MUST (ING 22)
RTECS #:9999999ZZ
Name:ING 21:BE COMPLETELY DRAINED BEFORE DISP. IF POSS GIVE TO
RECONDITIONER FOR CLEANING. DO NOT USE WELDING/CUTTING(ING 23)
RTECS #:9999999ZZ
Name:ING 22:TORCHES ON/NEAR CONTAINERS (EMPTY/FULL) BECAUSE
PRODUCT, INCLUDING RESIDUE, CAN IGNITE EXPLOSIVELY.
RTECS #:9999999ZZ
Name:RESP PROT:PRESSURE MODE IS ADVISED.
RTECS #:9999999ZZ
Name:VENT:FRESH AIR MOVEMENT AT FLOOR LEVEL BY NORMAL CROSS
VENTILATION OR PREFERABLY EXPLOSION PROOF EXHAUST FANS.
RTECS #:9999999ZZ
Name:TOLUENE; (TOLUOL) (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: >35%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: >10%
OSHA PEL:500 PPM, C; 1000
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:METHANOL; (METHYL ALCOHOL) (SARA III)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: 25%
OSHA PEL:S,200PPM/250STEL
ACGIH TLV:S,200PPM/250STEL; 93
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:ACETONE (SARA III)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: <25%
OSHA PEL:1000PPM
ACGIH TLV:750PPM/1000STEL;9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:PARAFFIN; (PARAFFIN WAX)
CAS:8002-74-2
RTECS #:RV0350000
Fraction by Wt: <5%
Other REC Limits:5MG/M3 OIL MIST(MFR)
OSHA PEL:2 MG/M3 (FUME)
ACGIH TLV:2 MG/M3 (FUME)
Name:SUPP DATA:INGEST:ASPIR OF MATL INTO LUNGS CAN CAUSE CHEM
PNEUM WHICH CAN BE FATAL. INGEST CAN CAUSE BLINDNESS/ (ING 7)
RTECS #:9999999ZZ
Name:ING 6:NAUS/VOM/DIARR/GI IRRIT/DEATH. CHRONIC: INTENTIONAL
MISUSE BY DELIB CONCENTRATING/INHALING PROD MAY BE (ING 8)
RTECS #:9999999ZZ
Name:ING 7:HARMFUL/FATAL. RPTS HAVE ASSOC RPTD/PRLGND OVEREXP TO
SOLV W/PERM BRAIN/NERV SYS/LIVER/KIDNEY DAM. (ING 9)
RTECS #:9999999ZZ
Name:ING 8:EXCESSIVE EXPOS MAY CAUSE CARBOXYHEMOGLOBINEMIA &
IMPAIR BLOOD'S ABILITY TO TRANSPORT OXYGEN. IF SIGNS OF (ING 10)
RTECS #:9999999ZZ
Name:ING 9:ALLERGY DEVELOP (BRTHG DFCLTY/EYE ITCHING/PRLNGD
ITCHING/REDNESS OF SKIN/HDCH/DIZZ/ETC) DISCONTINUE USE (ING 11)
RTECS #:9999999ZZ
Name:ING 10:OF PROD IMMED & CONSULT MD. CAUTION: DRINKING
ALCOHOL SHORTLY BEFORE, DURING & AFTER EXPOS TO SOME SOLV (ING 12)
RTECS #:9999999ZZ
Name:ING 11:MAY CAUSE UNDESIRABLE EFFECTS.
RTECS #:9999999ZZ
Name:FIRST AID PROC:INDUCE VOMITING. GET MED ATTN PROMPTLY.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NOTE: TOLUENE 108-88-3 APPEARS ON NAVY
LISTING OF OCCUP CHEM REPROD HAZARDS. CONSULT WITH APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLNG & EXPOS
RECOMMENDATIONS . CHLORO CARBON MATLS HAVE PRDCED SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:DICHLOROMETHANE: GROUP 2B, IARC VOL 7,
P.194, 1987; ANTIC TO BE CARCIN, NTP 6TH ANNUAL RPT ON CARCINOGEN,
1991. .
Effects of Overexposure:HLTH HAZ:EFT IN HUMANS. ADRENOMIMETICS (E.G.
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE:
EYES:CAN CAUSE SE V IRRIT, REDNESS, TEARING & BLURRED VISION. MAY
CAUSE TRANSIENT INJURY TO CORNEA. SKIN:MAY CAUSE SLIIGHT (SUPP
DATA)
Medical Cond Aggravated by Exposure:PERSONS THOUGHT TO HAVE HEART OR
RESPIRATORY PROBLEMS SHOULD SEEK MEDICAL ADVICE BEFORE USING
SOLVENTS OF ANY KIND.
======================= First Aid Measures =======================
First Aid:SKIN:WASH THORO W/SOAP & WATER. THORO LAUNDER CONTAMD CLTHG
BEFORE REUSE. EYE:FLOOD W/PLENTY OF WATER W/EYELIDS OPEN FOR AT
LEAST 15 MINS & GET MED ATTN PROMPTLY. INHAL:IF ILLNESS OCCURS,
REMOVE TO FR ESH AIR. IF BRTHG IS DFCLT, GIVE OXYGEN. IF BRTHG HAS
STOPPED, START ARTF RESP. CALL MD IMMED. INGEST:IMMED GIVE 1 OR 2
GLASSES OF WATER & CALL MD, HOSP EMER ROOM OR POIS CTL CTR FOR WAY
TO (ING 13)
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:>80F,>27C
Extinguishing Media:WATER FOG, REGULAR FOAM, CARBON DIOXIDE & DRY
CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT . STRAIGHT WATER STREAM WILL SPREAD
FIRE.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL HCL &
PHOSGENE . VAPS ARE HVR THAN AIR & MAY BE MOVED BY VENT & IGNITE
EXPLOSIVELY AT LOCATIONS FAR FROM HNDLNG (SUP DAT)
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR PROPER PROT EQUIP. STOP SPILL AT SOURCE.
KEEP OUT OF GROUND WATER/STREAMS. TRANSFER MATL TO METAL CONTRS.
ABSORB REMAINDER W/ABSORB MATL & SHOVEL INTO CONTRS. THEN WASH AREA
THORO W/WATER & DETER GENT. VENT ADEQUATELY W/GOOD FRESH AIR (ING
14)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL PLACE, OUT OF HOT SUN &
BELOW 90F. DO NOT STORE WHERE VAPORS MAY COME IN CONTACT W/FLAMES,
SPARKS & HEAT.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
OF ARC WELDING, OPEN FLAMES OR HOT SURF. HEAT &/OR UV RADIA MAY
CAUSE FORMATION OF HCL &/OR PHOSGENE . FLAMM MATLS SHOULD NOT BE
STORED IN B ELOW GROUND AREAS THAT CANNOT (ING 17)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FOR LEVEL UP TO 2% FOR 1/2 HR OR LESS, A
NIOSH/MSHA APPRVD FULL-FACE MASK W/CANISTER FOR ORG VAPS & METHANOL
SHOULD BE USED. ABOVE 2% & EMERGENCIES, A NIOSH/MSHA APPRVD SCBA
W/FULL FACEPIECE OPERATED IN A PRESS DEMAND OR OTHER POS (ING 24)
Ventilation:CARE MUST BE EXCERCISED TO PVNT VAPS FROM COLLECTING IN
LOW, UNVENTD AREAS. ADEQ VENT MUST BE PROVIDED W/GOOD (ING 25)
Protective Gloves:COTTON LINED NEOPRENE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LNTH FCSHLD .
Other Protective Equipment:EYEWASH STATION W/SAFETY SHOWERS. WEAR LONG
SLEEVED SHIRTS & LONG PANTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:LOCATION. KEEP AWAY FROM SPARKS/OPEN FLAMES/ALL IGNIT
SOURCES. EFTS OF OVEREXP: REDDENING. PRLNGD/RPTD CONT CAN CAUSE
IRRIT, DEFATTING, DERM & MAY RSLT IN ABSORP OF HARMFUL AMTS & SYMPS
SIMI LAR TO INGEST. INHAL:VAPS CAN CAUSE NASAL & RESP IRRIT, DIZZ,
WEAK, FATIGUE, HDCH, NAUS, UNCON & ASPHY. (ING 6)
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:104F/40C
Vapor Pres:RETARDED
Vapor Density:>1
Spec Gravity:0.88
Evaporation Rate & Reference:<1 ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:THICKENED,ORANGE LIQUID,AROMATIC ODOR
Percent Volatiles by Volume:>90
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ALKALIES & STRONG ACIDS. MAY REACT
W/ALUMINUM.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
HYDROGEN CHLORIDE, PHOSGENE & CHLORINE.
==================== Disposal Considerations ====================
Waste Disposal Methods:CANNOT BE NEUTRALIZED. MUST NOT BE DUMPED ON
GROUND OR BE ALLOWED TO CONTAM GROUND WATER/STREAMS/OTHER BODIES OF
WATER. SOLIDS COLLECTED FROM STRIPPING SHOULD BE SCREENED OUT. DISP
OF CONTAMD REMOVER AS SPENT SOLV TO A LICENSED RECLAIMER. (ING 16)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|