===================== Product Identification =====================
MSDS NAME:POLYDIP
NIIN:00N012588
MSDS Number: BQPJR
=== Responsible Party ===
Company:POLYTECH
Address:2520 SAN FERNANDO ROAD
City:LOS ANGELES
State:CA
ZIP:90065
Country:US
Info Phone Num:800-252-0180
Emergency Phone Num:800-252-0180
CAGE:0FWB4
=== Contractor Identification ===
Company:POLYTECH
Address:2520 SAN FERNANDO ROAD
Box:City:LOS ANGELES
State:CA
ZIP:90065
Country:US
Phone:213-223-3232/800-421-9402
CAGE:0FWB4
============= Composition/Information on Ingredients =============
Name:POTASSIUM HYDROXIDE
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 2.0%
Other REC Limits:N/K
OSHA PEL:2 MG/M3 C
ACGIH TLV:2 MG/M3 C
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:CRESYLIC ACID
CAS:95-48-7
RTECS #:GO6300000
Fraction by Wt: 4.0%
Other REC Limits:N/K
OSHA PEL:5 PPM SKIN
ACGIH TLV:5 PPM SKIN
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:PHENOL
CAS:108-95-2
RTECS #:SJ3325000
Fraction by Wt: 12.0%
Other REC Limits:N/K
OSHA PEL:5 PPM SKIN
ACGIH TLV:5 PPM SKIN
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:METHYLENE CHLORIDE
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 55.0%
Other REC Limits:N/K
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE.PROLONGED SKIN EXPOSURE CAN
CAUSE DERMATITIS DUE TO REMOVAL OF SKINS NATURAL OILS.INGESTION CAN
AFFECT CENTRAL NERVOUS SYSTEM,INTESTINAL TRACT,LIVER,KIDNEYS AND
BONE MARROW.FUMES MAY BE TOXI C.PROLONGED & REPEATED EXPOSURE TO
>200PPM CAN CAUSE ACUTE INTOXICATION,WHICH CAN BE FATAL.
Explanation of Carcinogenicity:METHYLENE CHLORIDE:ANTICIPATED TO BE A
CARC(NTP,GROUP 2,1991).INADEQ EVID FOR CARC IN HUM/SUFF EVID FOR
CARC IN (SUPDAT)
Effects of Overexposure:EYES:SEVERE IRRIT & DEHYDRATION OF EYE &
EYELIDS.SKIN:SLIGHT IRRIT.INGEST:SEVERE IRRIT.INHAL:FUMES-NARCOTIC
EFFECTS,NAUSEA,DIZZINESS,DOUBLE VISION,HEADACHE & VOMIT.PRLNG &
REPEATED EXPOS TO >200 PPM-P OSS ACUTE INTOXICATION (IRRIT OF
EYE,NOSE,LUNGS,FULLNESS OF HEAD,MENTAL CONFUSION.POSS
HDCH,STUPEFACTION,NAUS,VOMIT).
Medical Cond Aggravated by Exposure:N/K
======================= First Aid Measures =======================
Eyes:FLUSH FOR 30 MIN W/ COOL WATER.CONSULT MD
IMMED.SKIN:FLUSH W/ LUKEWARM WATER FOR 15 MIN.IF DEFATTING HAS
OCCURED,SKIN LOTION IS ADVISED.CONSULT MD IF IRRIT
PERSISTS.INGEST:INDUCE VOMIT.DRINK LOTS OF MILK OR WATER.CONSULT
MD IMMED.INHAL:REMOVE TO CLEAN ATMOS & ADMIN O*2 IF AVAIL.CONSULT
MD IMMED.MD NOTE:METHYLENE CHLORIDE HAS PRODUCED SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIM (SEE SUPP)
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:SAND,DRY CHEMICAL,DRY FOAM,HALON,WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SELF
CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMP PROD MAY INCLUDE HCL
.MATERIAL SUBJECTED TO HIGH HEAT FOUND AT FIRE SITE MAY DECOMPOSE
INTO A HIGHLY TOXIC NERVE GAS CALLED PHOSGENE.
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL:FLUSH WITH WATER TO INDUSTRIAL SEWER
LINE.LARGE:CONTAIN WITH DIKES OF ABSORBENT MATERIALS SUCH AS
CLAY,SAND OR VERMICULITE.COLLECT MATERIAL AND DISPOSE OF MATERIAL
IN CERTIFIED CLASS ONE DISPOSA L FACILITY.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:CHEMICALS CAN BE HAZARDOUS IF NOT
RESPECTED.USE OF PROPER EQUIP & HNDLG PROCEDURES CAN REDUCE
POSSIBILITY OF SERIOUS INJURY & TIME LOSS ACCIDENTS.
Other Precautions:NO SMKNG IN USE AREA.DO NOT USE IN GENL VICIN OF ARC
WELDING/OPEN FLAMES/HOT SURF. HEAT &/OR UV RADIATION MAY CAUSE FORM
OF HCL/PHOSGENE . AVOID HI HEAT. USE PROPER HOUSEKEEPING. DO NOT
MIX CHEM UNLESS INSTRUCTED BY QUALIFIED PERSON.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .WHEN USING THIS MATERIAL IN CONFINED SPACE,USE
OF PERSONAL RESPIRATORY PROTECTION IS RECOMMENDED.
Ventilation:LOCAL & GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:RUBBER OR PLASTIC.
Eye Protection:CHEMICAL WORK GOGG & FACE SHIELD.
Other Protective Equipment:WHEN HANDLING CHEMICALS IN 55 GALLON DRUMS
USE OF STEEL TOED RUBBER BOOTS AND A SPLASH APRON IS RECOMMENDED.
Work Hygienic Practices:N/K
Supplemental Safety and Health
ROUTES OF ENTRY:INHALATION/SKIN/INGESTION EXPLAN OF CARC:ANIM
(IARC,GROUP2B,1987).ACGIH A2=SUSP HUM CARC (1991).KNOWN TO CAUSE
CANCER (CAL PROP 65,1988).FIRST AID PROC:AND COULD HAVE A SIMILAR E
FFECT IN HUM.USE ADRENERGICS (EPINEPHRINE) ONLY FOR LIFE-SUSTAINING
USES IN HUMANS EXPOSED TO METHYLENE CHLORIDE .
================== Physical/Chemical Properties ==================
HCC:C2
Boiling Pt:B.P. Text:107F,42C
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Spec Gravity:1.29 (WATER=1)
Evaporation Rate & Reference:0.99 (WATER=1)
Solubility in Water:NONSOLUBLE
Appearance and Odor:BI-PHASE LIQUID WITH A HYDROCARBON ODOR.
Percent Volatiles by Volume:82
================= Stability and Reactivity Data =================
N/K
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:HCL .EXPOSURE TO HIGH HEAT AT FIRE
SITE MAY CAUSE DECOMP INTO HIGHLY TOXIC NERVE GAS CALLED PHOSGENE.
Conditions to Avoid Polymerization:UNDER NORMAL CONDITIONS HAZARDOUS
POLYMERIZATION WILL NOT OCCUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .ALL HAZARDOUS MATERIALS MUST
BE SOLIDIFIED AND DISPOSED OF IN EPA APPROVED CLASS ONE FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|