LD50 LC50 Mixture:ORAL LD50 (RAT): 1311 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE & SKIN IRRITANT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: DROWSINESS. SKIN: DRYING, CRACKING.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. TREAT SYMPTOMATICALLY.
EYES/SKIN: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. OBTAIN
MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:99C/210F
Lower Limits:1.7%
Upper Limits:10%
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, CO2, ALCOHOL FOAM
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING. USE WATER SPRAY TO KEEP FIRE-EXPOSED
CONTAINERS COOL.
Unusual Fire/Explosion Hazard:AUTOIGNITION TEMP: 452C(846F)
Spill Release Procedures:SMALL: COLLECT W/ABSORBENT MATERIALS. LARGE:
FLUSH W/WATER SPRAY. PREVENT RUNOFF FROM ENTERING DRAINS, SEWERS OR
STREAMS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP FROM OXIDIZING MATERIALS. SINCE
EMPTIED CONTAINERS RETAIN PRODUCT RESIDUE, FOLLOW LABEL WARNINGS
EVEN AFTER CONTAINER IS EMPTIED.
Other Precautions:PREVENT EYE & SKIN CONTACT.
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR FOR ORGANIC VAPOR
& MIST.
Ventilation:GENERAL; TYPICALLY 10 AIR CHANGES/HR. RATES SHOULD BE
MATCHED TO CONDITIONS. LOCAL EXHAUST/ENCLOSED HANDLING SYSTEM.
Eye Protection:SAFETY GLASSES W/SIDE SHIELD, GOGGLES
Other Protective Equipment:FACE SHIELD, EYE BATH, WASHING FACILITIES
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. GOOD INDUSTRIAL
HYGIENE PRACTICE SHOULD BE FOLLOWED.
Supplemental Safety and Health
PRODUCT HAS A LOW POTENTIAL TO AFFECT AQUATIC ORGANISMS/SECONDARY WASTE
TREATMENT MICROORGANISMS/GERMINATION/EARLY GROWTH OF PLANTS.
LABORATORY STUDIES SHOW PRODUCT CAN BE BIODEGRADED BY ACTIVATED SLU
DGE FROM DOMESTIC SEWAGE TREATMENT PLANTS/READILY SUSCEPTIBLE TO
BIODEGRADATION IN RIVERS BY MICROBIAL POPULATIONS.
Waste Disposal Methods:INCINERATE IN ACCORDANCE W/FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their