LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: ANESTH, IRRIT OF RESP
TRACT/NERV SYS DEPRESS-CHARACT BY HDCH, DIZZ, NAUS/POSS UNCON.
SKIN/EYE: PRIMARY IRRIT. PRLNGD/RPTD CONT TO SKIN MAY CAUSE
DERM-EXERCISE DUE CARE. SYMPS OF EXPOS: MAY CAUS E NAUS/DIZZ. SKIN:
IRRIT, RED. EYES: PRIMARY IRRIT. SKIN ABSORP: MAY CAUSE
IRRIT/BURNING SENSATION. INGEST: NOT APPLIC.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE FROM EXPOS & RESTORE BRTHG. SEEK MED ATTN.
SKIN: WASH AFFECTED AREA. REMOVE CONTAMD CLTHG, SEE PHYS IF ANY
IRRIT PERSISTS. EYE: FLUSH IMMED W/WATER FOR @ LST 15 MIN & TAKE TO
A PHYS. ING EST: CALL MD IMMED .
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:-22F,-30C
Lower Limits:0.7%
Upper Limits:12.8%
Extinguishing Media:FOAM, ALCOHOL FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE, BUT WATER SPRAY MAY BE USED TO COOL
CONTRS EXPOSED TO HEAT/FIRE TO PVNT (SUPDAT)
Unusual Fire/Explosion Hazard:CLOSED CCONTAINERS MAY EXPLODE DUE TO
BUILD UP OF PRESS FORM EXTREME HEAT/FIRE. AEROSOL SPRAY IS
EXTREMELY FLAMMABLE. DO NOT PUNCTURE.
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT; FLAMES, SPAKS,
STATIC ELEC & ELECTRICAL. VENT AREA & SOAK UP W/INERT ABSORB USING
NON-SPARKING TYPE TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 120F. DO NOT
STORE/USE NEAR HEAT, SPARKS/FLAME. DO NOT GET IN EYES. DO NOT
BREATHE VAPS.
Other Precautions:AVOID SKIN CONT. DO NOT TAKE INTERNALLY. SMOKING
WHILE USING PROD MYST BE STRICTLY PROHIBITED. IN ADDN TO ALL OTHER
HAZ & PREC-DUST FROM SANDING DRY PAINT FILMS SHOULD BE TREATED AS A
NUISANCE DUST WI TH A TLV OF 10 MG/M3 CUBIC METER.
Respiratory Protection:OUTDOORS: WE RECOMM AN NIOSH/MSHA APPRVD
PARTICULATE FILTER TO REMOVE ANY AIRBORNE OVERSPRAY. IN RESTRICTED
AREA W/POOR VENT & CLOSE TO TLV, A NIOSH/MSHA APPRVD RESP W/ORG VAP
CARTRIDGE IS RECOMMENDED .
Ventilation:ALL APPLICATN AREAS SHOULD BE ADEQUATELY VENTD IN ORDER TO
KEEP INGRED BELOW THEIR EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN AND SAFETY SHOWER. REMOVE
& WASH CONTAMD CLTHG BEFORE RE-USE.
Work Hygienic Practices:AVOID PROLONGED OR REPEATED CONTACT. DO NOT
BREATHE VAPORS.
Supplemental Safety and Health
FIRE FIGHT PROC: PRESSURE BUILD UP.
Boiling Pt:B.P. Text:-10F,-23C
Vapor Density:HVR/AIR
Spec Gravity:0.9(H*2O=1)
Evaporation Rate & Reference:>N-BUTYL ACETATE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:OPAQUE LIQUID WITH A SOLVENT BASED ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE.
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.