Search   
MSDS  : INITIATOR, CA-850402
CAS  : 7440-67-7
7778-74-7
7778-74-7
NAME  : initiating material (consisting of ings 2 & 3)
zirconium
perchloric acid, potassium salt (1:1); (potassium
pressure composition (consisting of ings 5 & 6)
titanium hydride
perchloric acid, potassium salt (1:1); (potassium
===================== Product Identification =====================

MSDS NAME:INITIATOR, CA-850402
NIIN:00N049056
MSDS Number: BVCMT
=== Responsible Party ===
Company:SPECIAL DEVICES INC
Address:16830 W PLACERITA CYN RD
City:NEWHALL
State:CA
ZIP:91321
Country:US
Info Phone Num:805-259-6658
Emergency Phone Num:805-259-0753
Preparer's Name:ROBERT C. GIBBS
CAGE:14720
=== Contractor Identification ===
Company:SPECIAL DEVICES, INC.
Address:16830 W. PLACERITA CANYON ROAD
Box:City:NEWHALL
State:CA
ZIP:91321
Phone:(805) 259-0753
CAGE:14720

============= Composition/Information on Ingredients =============

Name:INITIATING MATERIAL (CONSISTING OF INGS 2 & 3)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K

Name:ZIRCONIUM
CAS:7440-67-7
RTECS #:ZH7070000
Fraction by Wt: <50%
OSHA PEL:5 MG/M3;10 STEL
ACGIH TLV:5 MG/M3;10 STEL

Name:PERCHLORIC ACID, POTASSIUM SALT (1:1); (POTASSIUM
PERCHLORATE)
CAS:7778-74-7
RTECS #:SC9700000
Fraction by Wt: >50%
OSHA PEL:N/K
ACGIH TLV:N/K

Name:PRESSURE COMPOSITION (CONSISTING OF INGS 5 & 6)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K

Name:TITANIUM HYDRIDE
Fraction by Wt: <30%
OSHA PEL:N/K
ACGIH TLV:N/K

Name:PERCHLORIC ACID, POTASSIUM SALT (1:1); (POTASSIUM
PERCHLORATE)
CAS:7778-74-7
RTECS #:SC9700000
Fraction by Wt: >65%
OSHA PEL:N/K
ACGIH TLV:N/K

===================== Hazards Identification =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:UN-CONTAINED INITIATION OF THIS
INITIATOR WILL EXPEL DANGEROUS SHRAPNEL.
Explanation of Carcinogenicity:NOT RELEVANT
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . EYES:IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
MD . SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD .

===================== Fire Fighting Measures =====================

Extinguishing Media:WATER, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EXPLOSIVE FORMULATION MAY EXPLODE OR
IGNITE WHEN EXPOSED TO FIRE.

================== Accidental Release Measures ==================

Spill Release Procedures:USE PPE & GROUNDING STRAP TO PREVENT DISCHARGE
OF ACCUMULATED ELECTROSTATIC CHARGES TO THE UNIT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:HANDLE CAREFULLY. KEEP FIRE AWAY.
CLASS C EXPLOSIVE.
Other Precautions:USE PERSONAL PROTECTIVE EQUIPMENT TO PREVENT INJURY
FROM SHRAPNEL, WHEN UNIT IS UN-CONTAINED.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE. SPECIAL: EXPLOSIVE OUTPUT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:FLAME RETARDANT SHOP COATS & BODY SHIELDING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
APPEAR/ODOR:HERMETICALLY SEALED CLOSURE; NO ODOR.

================== Physical/Chemical Properties ==================

Appearance and Odor:STAINLESS STEEL BODY W/STD MS CONNECTOR & THREADED
OUTPUT END. (SUPP DATA)

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
UNKNOWN.
Stability Condition to Avoid:TEMPERATURES IN EXCESS OF 600F. KEEP FIRE
AWAY.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . INITIATE BY APPLICATION OF 5 AMPERES OF CURRENT TO
THE BRIDGEWIRE CIRCUIT. UNIT SHOULD BE CONTAINED TO PREVENT HAZARDS
OF SHRAPNEL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
MS-400G, BASE COMPONENT 25068-38-6
1330-20-7
41638-13-5
1569-02-4
3101-60-8
7727-43-7
1344-28-1
MS-400G, HARDENER COMPONENT 1330-20-7
1569-02-4
64742-95-6
14808-60-7
68991-84-4
68443-08-3
13983-17-0
1344-28-1
INITIATOR, 103377-3 7440-67-7
7778-74-7
7778-74-7
INITIATOR, EX-8502243 7440-67-7
7778-74-7
7778-74-7
INITIATOR, CA-850402 7440-67-7
7778-74-7
7778-74-7
TITANIUM DIOXIDE, 4162 13463-67-7
TITANIUM DIOXIDE, 4962 13463-67-7
SODIUM, 9412 7440-23-5
SODIUM, 9410 7440-23-5
GYPSUM 10101-41-4
14808-60-7
LAND PLASTER 10101-41-4
14808-60-7
AGRICULTURAL GYPSUM 10101-41-4
14808-60-7
CEMENT ROCK 10101-41-4
14808-60-7
TRIBOLUBE-47RP
TRIBOLUBE-47
SPANTEX 13463-67-7
1330-20-7
107-21-1
1317-65-3
TOLUOL RESIN 108-88-3
TUBE LUBE
HEAVY DUTY RUBBING COMPOUND 7732-18-5
64742-88-7
1317-95-9
13463-67-7
8002-09-3
PDL 2001-10 FR-COMPONENT A 101-68-8
103-71-9
9016-87-9
PDL 2001-10 FR-COMPONENT B
PULVALURE 7B-100 BLACK LOW CURE EPOXY 7727-43-7
ACRYSHELL-SEMIGLOSS 107-21-1
RUSTICIDE RUST REMOVER 7664-38-2
RED-X CORONA DOPE, 10-5012 8032-32-4
1330-20-7
108-88-3
67-64-1
74-90-6
1309-37-1
RADEX P 1310-73-2
TT-P-19 107-21-1
TT-E-490 SG SILICONE ALKYD, 0057 64742-88-7
NATURAL GAS 74-82-8
74-84-0
74-98-6
STRIPING PAINT, 785 FLUORESCENT RED/ORANGE 1330-20-7
67-64-1
64742-89-8
8052-41-3
74-98-6
75-28-5
106-97-8
K801 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
K803 12069-94-2
12070-08-5
7440-48-4
12070-12-1
7440-02-0
12070-06-3
KZ801 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
KZ803 12070-08-5
7440-48-4
12070-12-1
7440-02-0
12070-06-3
12069-94-2
SP269 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
SP272 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
SP297 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
SP318 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
SPZ318 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
6% NI POWDER 12070-12-1
7440-02-0
12070-06-3
12069-94-2
12070-08-5
7440-48-4
AA-18, 5112 1314-13-2
1314-41-6
AA-18, 6100 1314-13-2
1314-41-6
ABRASIVE GRAINS AND POWDERS, 30-40S 1302-62-1
ABRASIVE GRAINS AND POWDERS, 16S 1302-62-1
ABRASIVE GRAINS AND POWDERS, 36S 1302-62-1
ABRASIVE GRAINS AND POWDERS, 50P 1302-62-1
ABRASIVE GRAINS AND POWDERS, 80P 1302-62-1
ABRASIVE GRAINS AND POWDERS, 100S 1302-62-1
ABRASIVE GRAINS AND POWDERS, 120P 1302-62-1
HEAVY DUTY EPOXY PRIMERS-BASE COMPONENT, HS 9369 107-98-2
1330-20-7
108-10-1

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net