MSDS NAME:LOW VOC REDUCER MEDIUM, DT1875
NIIN:00N053694
MSDS Number: BVQZT
=== Responsible Party ===
Company:PPG INDUSTRIES INC
Address:4325 ROSANNA DR
City:ALLISON PARK
State:PA
ZIP:15101
Country:US
Info Phone Num:800-441-9695
Emergency Phone Num:304-843-1300
CAGE:47695
=== Contractor Identification ===
Company:PPG INDUSTRIES INC
Address:ONE PPG PLACE
Box:City:PITTSBURGH
State:PA
ZIP:15272
Country:US
Phone:1-800-245-2974 (CAL HYPO)
CAGE:47695
============= Composition/Information on Ingredients =============
Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:10F,-12C
Lower Limits:1.1%
Extinguishing Media:USE NFPA CLASS B EXTINGS (CARBON DIOXIDE, DRY
CHEM/UNIVERSAL AQ FILM FORMING FOAM) DESIGNED TO EXTING NFPA
CLASS(SUPDAT)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. WATER SPRAY MAY BE USED TO COOL CLSD
CNTNRS TO PVNT PRESS BUILD-UP & POSS(SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAMES. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. DO NOT APPLY ON HOT (SUPDAT)
Boiling Pt:B.P. Text:>136F,>58C
Vapor Pres:82.1
Vapor Density:HVR/AIR
Spec Gravity:0.75
Evaporation Rate & Reference:572 (BUOAC=100)
Solubility in Water:10%
Appearance and Odor:NON-VISCOUS LIQUID W/ODOR CHARACTERISTIC OF
SOLVENTS LISTED IN INGREDIENTS.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG ALKALIES, STRONG MINERAL ACIDS OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.