Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE
======================= First Aid Measures =======================
First Aid:SKIN: WASH W/SOAP & WATER. EYES: FLUSH W/LARGE AMOUNTS OF
WATER. INGESTION: DON'T INDUCE VOMITING. KEEP PERSON WARM & QUIET.
INHALATION: REMOVE TO FRESH AIR. ADMINISTER OXYGEN/CPR AS REQUIRED.
KEEP PE RSON WARM & QUIET. OBTAIN MEDICAL ATTENTION IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:>300F
Extinguishing Media:REGULAR FOAM, CO2, DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA W/FULL FACEPIECE OPERATED IN
POSITIVE PRESSURE DEMAND MODE.
Unusual Fire/Explosion Hazard:WATER/FOAM MAY CAUSE VIOLENT FROTHING
ESPECIALLY IF SPRAYED INTO CONTAINERS OF HOT, BURNING LIQUID.
WELDING/CUTTING TORCH ON/NEAR DRUM CAN IGNITE EXPLOSIVELY.
Spill Release Procedures:SMALL: ABSORB LIQUID ON VERMICULITE, FLOOR
ABSORBENT/OTHER ABSORBENT MATERIAL. LARGE: PREVENT RUN-OFF TO
SEWERS, STREAMS/OTHER BODIES OF WATER. EVACUATE NON-ESSENTIAL
PERSONNEL. STOP AT SOURCE, DIKE A REA, PUMP LIQUID INTO SALVAGE
TANK. (SEE SUPP)
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T TRANSFER TO UNLABELED CONTAINER.
DON'T USE CUTTING/WELDING TORCH ON CONTAINER, EVEN EMPTY. FOR
INDUSTRIAL USE ONLY.
Other Precautions:BEFORE USE, REVIEW MSDS. CONTAINERS MAY BE HAZARDOUS
WHEN EMPTIED. SINCE EMPTIED CONTAINERS RETAIN PRODUCT RESIDUES, ALL
PRECAUTIONS MUST BE OBSERVED.
Respiratory Protection:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Ventilation:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Protective Gloves:NOT NORMALLY REQUIRED.
Eye Protection:NOT REQUIRED UNDER NORMAL CONDITIONS.
Other Protective Equipment:NORMAL WORK CLOTHING COVERING ARMS & LEGS.
Work Hygienic Practices:REMOVE & LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
SPILL PROCEDURES CONT'D: REMAINING LIQUID MAY BE TAKEN UP ON SAND,
CLAY, EARTH, FLOOR ABSORBENT/OTHER ABSORBENT MATERIAL & SHOVELED
INTO CONTAINERS.
Waste Disposal Methods:LARGE: DESTROY BY LIQUID INCINERATION. DISPOSE
OF IN ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.