LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES/SKIN: MAY BE MILDY
IRRITATING. INHALATION: MAY CAUSE HEADACHE, DIZZINESS, NAUSEA,
UNCONSCIOUSNESS. INGESTION: MAY IRRITATE STOMACH AND INTESTINES.
MAY BE ASPIRATED INTO LUNGS IF SWALLOWED RESULTING IN PULMONARY
EDEMA AND CHEMICAL PNEUMONITIS. CHRONIC: NO KNOWN APPLICABLE
INFORMATION. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: OTHER HEALTH EFFECTS: ISOPARAFFINIC
HYDROCARBONS HAVE PRODUCED KIDNEY INJURY IN MALE RATS ONLY. NO
COMPARABLE HEALTH HAZARD FOR KIDNEY DISEASE IS KNOWN TO OCCUR IN
HUMANS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE: FLUSH EYES W/WATER FOR AT LEAST 15 MIN. IF IRRIT
DEVELOPS, SEEK MED ATTN. SKIN: IMMED WASH W/SOAP & WATER. IF IRRIT
DEVELOPS, SEEK MED ATTN. INHAL: REMOVE FROM CONTAMD AIR. IF ILLNESS
DEVELOPS, S EEK MED ATTN. INGEST: DO NOT INDUCE VOMIT. SEEK IMMED
MED ATTN. NOTE TO MD: GASTRIC LAVAGE USING A CUFFED ENDOTRACHEAL
TUBE MAY BE PERFORMED AT YOUR DISCRETION.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:105F,41C
Lower Limits:1%
Upper Limits:3%
Extinguishing Media:DRY CHEMICAL, FOAM, CARBON DIOXIDE (CO*2).
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
EVACUATE AREA OF ALL UNNEC PERS. SHUT OFF SOURCE, IF POSS. WATER
FOG/SPRAY MAY BE USED TO COOL (SUPDAT)
Unusual Fire/Explosion Hazard:CARBON OXIDES FORMED WHEN BURNED.
Spill Release Procedures:PROTECT FROM IGNITION. CONTAIN SPILL. KEEP OUT
OF WATER SOURCES AND SEWERS. ABSORB IN DRY, INERT MATERIAL. REFER
TO INGREDIENT SECTION AND CONTACT APPROPRIATE SAFETY PERSONNEL FOR
RESPIRATOR REQUIREME NTS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, DRY, WELL-VENT AREA.
PROTECT FROM SOURCES OF IGNIT. PROVIDE MEANS OF CONTROLLING LEAKS &
SPILLS. BOND & GROUND DURING LIQ (SUPDAT)
Other Precautions:AVOID CNTCT W/EYES, SKIN/CLTHG. AVOID BRTHG VAPS.
WEAR PROT EQUIP &/OR GARMENTS IF EXPOS CNDTNS WARRANT. FOR WORK ON
CONTAMD EQUIP, WEAR PROT EQUIP &/OR GARMENTS IF CNDTNS WARRANT.
CNTCT IMMED SUPERVI SOR FOR SPECIFIC INSTRUCTIONS (SUPDAT)
Respiratory Protection:NOT GENERALLY REQUIRED UNLESS NEEDED TO PREVENT
RESPIRATORY IRRITATION. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:USE ADEQUATE VENTILATION.
Protective Gloves:RUBBER, NEOPRENE/VINYL ALCOHOL GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:PERSONAL PROT INFO IS BASED UPON GEN INFO AS
TO NORM USES & CNDTNS. WHERE SPEC/UNUSUAL USES/CNDTNS EXIST, IT
(SUPDAT)
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
SPEC GRAV: 0.74 @ 60F (H*2O=1). FIRE FIGHT PROC: EXPOSED EQUIP &
CNTNRS. HNDLG/STOR PREC: TRANSFER. KEEP CNTNRS CLSD. OTHER PROT
EQUIP: IS SUGGESTED THAT THE EXPERT ASSISTANCE OF INDUSTRIAL
HYGIENIST/ OTHER QUALIFIED PROFESSIONAL BE SOUGHT.OTHER PREC:
BEFORE WORK IS INITIATED.
Boiling Pt:B.P. Text:>315F,>157C
Vapor Pres:0.1 PSIA
Vapor Density:>1
Spec Gravity:SUPDAT
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID; MILD ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXYGEN OR STRONG OXIDIZING MATERIALS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:CARBON OXIDES FORMED WHEN BURNED.
Waste Disposal Methods:INSURE CONFORMITY WITH ALL APPLICABLE FEDERAL,
STATE AND LOCAL DISPOSAL REGULATIONS. INCINERATE UNDER CONTROLLED
CONDITION OR PLACE IN RCRA PERMITTED WASTE MANAGEMENT FACILITY.
RCRA CLASSIFICATION: IG NITABLE - D001.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.