===================== Product Identification =====================
MSDS NAME:POCO GRAPHITE EDM-C3
NIIN:00F000147
MSDS Number: BBFYV
=== Responsible Party ===
Company:POCO GRAPHITE, INC. SUBSIDIARY OF UNION OIL CO.-CA
Emergency Phone Num:817/627-2121
CAGE:EO446
=== Contractor Identification ===
Company:POCO GRAPHITE INC.
Address:1601 SOUTH STATE STREET
Box:City:DECATUR
State:TX
ZIP:76234-2742
Country:US
Phone:817-627-2121/202-483-7616
CAGE:53241
Company:POCO GRAPHITE, INC. SUBSIDIARY OF UNION OIL CO.-CA
CAGE:EO446
============= Composition/Information on Ingredients =============
Name:GRAPHITE, SYNTHETIC
CAS:7440-44-0
RTECS #:FF5250100
Fraction by Wt: 57.0%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:2 MG/M3 TDUST; 9293
Name:COPPER (SARA III)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: 43.0%
OSHA PEL:0.1MG/M3 FUME/1 DUST
ACGIH TLV:0.2MG/M3 FUME; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
Effects of Overexposure:VERY LOW OVERALL TOXICITY.
======================= First Aid Measures =======================
First Aid:PNEUMOCONIOSIS FROM CHRONIC OVEREXPOSURE TO DUST.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER SPRAY
Fire Fighting Procedures:COOL WITH WATER
Unusual Fire/Explosion Hazard:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:NONE
Other Precautions:CLEAN UP PROCEDURE SHOULD INSURE MINIMIZING
ADDITIONAL DUST; VACUUM DUST RATHER THAN SWEEP, FOR EXAMPLE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:RESPIRATOR WITH APPROVED PARTICULATE FILTER
WHENDUST IS OVER TLV
Ventilation:LOCAL EXHAUST WHEN DUST IS IN EXCESS OF EXPOSURE LIMITS
Other Protective Equipment:APPROPRIATE PROTECTION FROM DUST SHOULD BE
USED IF MACHINING
Supplemental Safety and Health
1601 SOUTH STATE STREET DECATUR, TX. 76234.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:4200F
Spec Gravity:2.97
Appearance and Odor:STEEL GREY TO BLACK
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF USED PRODUCT IN ACCORDANCE WITH
APPLICABLE LOCAL, COUNTY, STATE AND FEDERAL REGULALTIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.