LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CORR ALKALI! WILL IRRIT/DMG
SKIN, EYES & MUCOUS MEMBS OF RESP & DIGESTIVE TRACTS. INHAL OF CONC
MISTS MAY CAUSE PNEUMONIA. INHALATION OR ABSORPTION THROUGH SKIN
MAY CAUSE LUNG, LIVER & KIDNEY D MG. INGEST MAY CAUSE NAUSEA,
VOMITING, DIZZINESS, DROWSINESS, COLLAPSE & COMA. CHRONIC: RPTD
EXPOS TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: SKIN MAY CAUSE CHRONIC DERMATITIS AS
WELL AS LUNG, LIVER OR KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:PERSONS WITH IMPAIRED BREATHING MAY
BE AT INCREASED RISK IF CONCENTRATED MISTS ARE INHALED. OPEN
WOUNDS, RASHES OR SORES MAY BE IRRITATED.
======================= First Aid Measures =======================
First Aid:SKIN: FLUSH W/WATER, THEN WASH THOROUGHLY WITH SOAP & WATER.
EYES: FLUSH WITH WATER FOR AT LEAST 15 MINS & SEEK MED ATTN.
INGEST: DRINK PLENTY OF WATER & CALL COLLECT (216)835-7233/CONSULT
MD IMMED. A VOID ALCOHOLIC BEVERAGES. DO NOT GIVE ANYTHING BY MOUTH
TO AN UNCON PERS. INHAL: MOVE VICTIM TO FRESH AIR/ SEEK MED ATTN IF
BRTHG DFCLTY PERSISTS. APPLY ARTF RESP IF NECESSARY.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:123F,51C
Extinguishing Media:WATER, CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. KEEP DRUMS THAT ARE EXPOSED TO FIRE COOL
W/WATER.
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID. TOXIC FUMES MAY BE
GENERATED. MAY FLASH IF WATER IS DRIVEN OFF.
Spill Release Procedures:CONTAIN SPILL IF WITHOUT RISK. REMOVE SOURCES
OF IGNITION. ABSORB ON INERT MATERIAL SUCH AS SAND OR CLAY AND
PLACE IN DRUMS FOR PROPER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
Other Precautions:AVOID SKIN & EYE CONTACT. DO NOT TAKE INTERNALLY.
AVOID BREATHING VAPORS OR MISTS.
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NOT REQUIRED UNDER NORMAL CONDITIONS OF
USE.
Ventilation:LOC EXHST: RECOMM IN CONFINED SPACES. MECH EXHST VENT
SUFFICIENT TO REMOVE AIR CONTAMS FROM OPERATOR'S AREA.
Protective Gloves:RUBBER OR IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:RUBBER APRON IF SPLASHING IS LIKELY, EMERG
EYE WASH AND DELUGE SHOWER WHICH MEETS ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING & BEFORE EATING,
DRINKING OR SMOKING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods:THIS MATERIAL IS A RCRA HAZARDOUS WASTE DUE TO
THE CHARACTERISTIC OF IGNITABILITY(D001). INCINERATE OR DISPOSE OF
IN ACCORDANCE WITH LOCAL, STATE & FEDERAL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their