silica, amorphous. ld50: (oral,rat) >7.5 g/kg. glycerol;(glycerin). ld50: (rat) 12,600 mg/kg. carbon black. ld50: (rat) >25.1 g/kg. silica, crystalline - quartz propane, 1-butoxy-2,3-epoxy-; (butyl glycidyl ether). ld50: explan of carcin: 1994: anticipated to be a carcinogen. spill proc: w/some inert absorb matl; sweep up & place in vent: spraying/curing at elevated temperatures. other prot equip: contact. barrier creams may be used in hygiene prac: drinking, smoking, wash face & hands with
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ALLERGIC SKIN RXNS/PRIMARY SKIN IRRIT
MAY BE PRODUCED BY PLNGD/RPTD DERMAL CONTACT W/EPOXY RESINS.
OVEREXP TO VAPOR DURING HEAT CURING MAY CAUSE IRRIT/INJURY OF RESP
TRACT & EYE IRRIT. DIRECT CONT W/M ATL MAY CAUSE MILD EYE & SKIN
IRRIT. ING 2: EYE/SKIN CONTACT WILL PRDCE MILD IRRIT. INHAL OF MIST
COULD(EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ: IARC
MONOGRAPHS, SUPP. VOL 7, PG 341, 1987: GROUP 2A. NTP 7TH ANNUAL RPT
ON CARCINS,(ING 6)
Effects of Overexposure:HLTH HAZ: CAUSE RESPIRATORY IRRIT. ING 3: ACUTE
OVEREXP MAY CAUSE SLIGHT RESP IRRIT. ING 4:PULM FUNCTION MAY BE
REDUCED BY INHAL OF RESP QUARTZ SILICA. OVEREXP CAN CAUSE
DELAYED(CHRONIC) FIBROSIS & OT HER LUNG INJURY. CHRONIC INHAL EXPOS
SHOWED THAT QUARTZ SILICA CAN CAUSE LUNG CANCER IN RATS BUT NOT
MICE.(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN: IMMED WASH AFFECTED AREAS W/SOAP & PLENTY OF WATER.
REMOVE CONTAMD CLTHG & SHOES. OBTAIN MED ATTN. DESTROY OR THORO
CLEAN SHOES BEFORE REUSE. DO NOT REUSE CONTAMD CLTHG W/OUT
LAUNDERING. EYE: IM MED IRRIGATE W/PLENTY OF WATER FOR AT LEAST 15
MINS. INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING(GIVE O*2/ARTF
RESP). INGEST: CALL MD IMMEDIATELY .
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:>212F,>100C
Extinguishing Media:USE WATER SPRAY, CARBON DIOXIDE/DRY CHEMICAL TO
EXTINGUISH FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. USE WATER TO KEEP CONTAINERS COOL.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Spill Release Procedures:WHERE EXPOS LEVEL IS NOT KNOWN, WEAR
NIOSH/MSHA APPRVD POSITIVE PRESS SELF-CONTAINED RESP. WHERE EXPOS
LEVEL IS KNOWN, WEAR NIOSH/MSHA APPRVD RESP SUITABLE FOR LEVEL OF
EXPOS. IN ADDITION TO PROT CLTH G/EQUIP, WEAR IMPERVIOUS BOOTS.
COVER (ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID PROLONGED OR REPEATED CONTACT
WITH SKIN. AVOID CONTACT WITH EYES.
Other Precautions:CUTTING, GRINDING/SANDING OF PARTS FABRICATED AFTER
CURING OF MATL MAY CREATE RESP DUST PARTICLES. RESP PROT APPROP FOR
THIS DUST MAY BE REQD. SEE "GUIDE TO INDUSTRIAL RESPIRATORY
PROTECTION"(NIOSH).
Respiratory Protection:WHERE EXPOS ARE BELOW THE PEL, NO RESP PROT IS
REQD. WHERE EXPOS EXCEED PEL, USE NIOSH/MSHA APPRVD RESP FOR MATL &
LEVEL OF EXPOSURE. A NIOSH/MSHA APPRVD FULL FACEPIECE RESP WILL
PROVIDE EYE & FACE PR OTECTION.
Ventilation:WHERE MATL IS NOT USED IN CLSD SYSTEM, GOOD ENCLOSURE & LOC
EXHST VENT SHOULD BE PROVIDED TO CONTROL EXPOS WHEN (ING 8)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES.
Other Protective Equipment:PROT CLTHG SUCH AS IMPERVIOUS APRON,
WORKPANTS, LONG SLEEVE WORK SHIRT/DISP COVERALLS ARE RECOMM TO PVNT
SKIN (ING 9)
Work Hygienic Practices:FOOD, BEVERAGES & TOBACCO PRODS SHOULD NOT BE
CARRIED, STORED/CONSUMED WHERE MATL IS IN USE. BEFORE EATING, (ING
10)
Supplemental Safety and Health
EFTS OF OVEREXP: THERE IS ALSO LTD HUMAN EVID WHICH SHOWS ASSOC OF LUNG
CANCER W/OCCUP EXPOS TO QUARTZ SILICA. ING 5: MOD EYE & SKIN IRRIT
IN RABBITS. CAUSE DERM SENSIT. IS MUTAGENIC IN A NUMBER OF IN
VITRO TESTS SUCH AS THE AMES ASSAY & MOUSE LYMPHOMA. IT CAUSED
CHROMOSOMAL ABNORMS IN EXPERIMENTAL ANIMALS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS, BASES, AMINES & STRONG OXDIZERS.
Stability Condition to Avoid:AVOID EXCESSIVE HEATING OVER LONG PERIODS
OF TIME.
Hazardous Decomposition Products:THERMAL DECOMP OR COMBUSTION MAY
PRODUCE PHENOLICS, OXIDES OF CARBON AND ALDEHYDES.
Conditions to Avoid Polymerization:AVOID OXIDIZING AGENTS, ACIDS, BASES
OR AMINES.
Waste Disposal Methods:DISPOSAL MUST BE MADE IN ACCORDANCE WITH
APPLICABLE GOVERNMENTAL, LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their