MSDS  : CIDEX PLUS 28 DAY SOLN/ACTIVATOR VIAL PRODUCT CODE:2785
CAS  : 111-30-8
25322-68-3
7732-18-5
NAME  : glutaraldehyde (glutaric dialdehyde)
polyethylene glycol
inert buffer salts
water
===================== Product Identification =====================

MSDS NAME:CIDEX PLUS 28 DAY SOLN/ACTIVATOR VIAL PRODUCT CODE:2785
NIIN:01-286-0421
MSDS Number: BXFYZ
=== Responsible Party ===
Company:JOHNSON & JOHNSON (FRMLY:SURGIKOS INC)
Box:90130
City:ARLINGTON
State:TX
ZIP:76010
Country:US
Info Phone Num:800-423-5850
Emergency Phone Num:800-423-5850
Preparer's Name:REGULATORY AFFAIRS
CAGE:DO392
=== Contractor Identification ===
Company:JOHNSON & JOHNSON MEDICAL INC. (SUB OF JOHNSON & JOHNSON)
Address:2500 ARBROOK BOULEVARD
Box:City:ARLINGTON
State:TX
ZIP:76014
Country:US
Phone:800-433-5170
CAGE:52780
Company:JOHNSON & JOHNSON ORTHOPAEDICS, INC
Address:501 GEORGE STREET
City:NEW BRUNSWICK
State:NJ
ZIP:08903
Phone:800-526-2459
CAGE:DO392

============= Composition/Information on Ingredients =============

Name:GLUTARALDEHYDE (GLUTARIC DIALDEHYDE)
CAS:111-30-8
RTECS #:MA2450000
Fraction by Wt: 3.4%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 0.2 PPM
ACGIH TLV:C 0.2 PPM; 9394

Name:POLYETHYLENE GLYCOL
CAS:25322-68-3
RTECS #:TQ3500000
Fraction by Wt: 10.0%
Other REC Limits:NONE RECOMMENDED

Name:INERT BUFFER SALTS
Fraction by Wt: 2.6%
Other REC Limits:NONE RECOMMENDED

Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 84.0%
Other REC Limits:NONE RECOMMENDED

===================== Hazards Identification =====================

LD50 LC50 Mixture:LD50 ORAL, RAT : 4250MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:DAMAGE,POSSIBLE CORNEAL
INJURY.GLUTARALDEHYDE VAP MAY CAUSE STINGING SENSATIONS W/EXCESS
TEARING,BLINKING,SLIGHT EXCESS REDNESS OF
CONJUNCTIVA.SKIN:IRRIT/DAMAGE.REPEATED EXPO RESULT IN SENSITIZATI
ON OR ALLERGIC CONTACT DERM.INHAL:RESPTRACT IRRIT.INGEST:IRRIT/CHEM
BURNS OF MOUTH/THROAT/ESOPHAGUS/STOMACH W/DISCOMFOR
Explanation of Carcinogenicity:PER MSDS:LISTED AS CARCINOGEN BY
NTP/IARC/OSHA:NO.
Effects of Overexposure:EYE:DAMAGE,CORNEAL INJURY,STINGING
SENSATION,TEARING,BLINKING,REDNESS OF
CONJUNCTIVA.SKIN:IRRIT/DAMAGE,SENSITIZATION,ALLERGIC CONTACT
DERM.INHAL:RESP TRACT IRRIT,STINGING SENSATION OF NOSE/THROAT,DISC
HARGE,BLEEDING FRM NOSE,COUGH,CHEST DISCOMFORT/TIGHTNESS,DIFFICULTY
W/BREATHING,SYMPTOMS OF BRONCHITIS/ASTHAM,HEAD.(SUP)
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE
PRE-EXISTING DERM.INHAL OF FLUTARALDEHYDE VAP MAY AGGRAVATE
PRE-EXISTING ASTHMA, BRONCHITIS, INFLAMMATORY OR FIBROTIC PULMONARY
DISEASES.

======================= First Aid Measures =======================

Eyes:IMMED FLUSH W/WATER & CONTINUE FOR @LEAST 15MINS.GET MED
ATTN W/O DELAY PREFERABLY FRM OPTHAMOLOGIST.SKIN:IMMED FLUSH
W/WATER & CONTINUE FOR @LEAST 15MINS.IRRIT PERSIST GET MED
ATTN.INHAL:REMOVE TO FRESH AIR. BREATH DIFFICULT GIVE OXYBY
QUALIFIED PERSONNEL.SYMPTOMS PERSIST GET MED ATTN.INGEST:DO NOT
INDUCE VOMIT.DRINK LG QUANT OF WATER.CALL PHYSICIAN
IMMED.PHYSICIAN:PROBABLE MUCOSAL (SUPPLE)

===================== Fire Fighting Measures =====================

Flash Point:NONE
Extinguishing Media:AFT WATER EVAPORATES REMAINING MATL WILL BURN.USE
CO2,DRY CHEM FOR SM FIRES,ALCOHOL-TY,ALL PURPOSE TYP FOAM FOR LG
FIRES
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHING SHOULD BE AVAILABLE TO FIREMAN.
Unusual Fire/Explosion Hazard:NONE.

================== Accidental Release Measures ==================

Spill Release Procedures:WEAR SUITABLE PROT EQPMT.SPILLS >1GAL:USE 500G
AMMONIUM CARBONATE POWDER PER GAL OF SPILL TO NEUTRALIZE
ODOR.CONSIDERABLE FUMES MAY BE LIBERATED BY DECONTAMIN RX.COLLECT
LIQ.SPILL <1GAL:WIPE W/SPONGE/ MOP DOWN AREA W/EQUAL MIXTURE (SEE
OTHER PRECAUTI)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:PRIOR TO ACTIVATION STORE IN ORIGINAL
SEALED CNTNR @ CONTROLLED ROOM TEMEPRATURE 59-86F/15-30C.USE CLSD
CNTNR W/TIGHTFITTING LID.
Other Precautions:USE IN WELL VENTI RM-IN 10AIR CHANGES/HR-IF LESS USE
LOC EXHAUT HOODS,DUCTLESS FUME HOODS/PORTABLE VENTI DEVICES
CONTAINING FILTER MEDIA WHICH ABSORB GLUTARALDEHYDE. SPILL:OF
HOUSEHOLD AMMONIA & WATER /FLUSH W/LG AMTS OF WATER DOWN DRAIN.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:ROUTINE:NONE REQUIRED. EMERGENCY:ORGANIC VAPOR
CARTRIDGE MASK OR SELF-CONTAINED BREATHING APPARATUS.
Ventilation:ROUTINE:MIN 10 AIR CHANGES/HR.IF LESS USE LOC EXHAUST
HOODS/DUCTLESS FUME HOOD/PORTABLE VENTI DEVICES REMOVES GLUTARALDE
Protective Gloves:NAT LATEX,ALLERGARD,RUBB,BUTYL GLOVES.
Eye Protection:SAF GLASSES, W/FACESHIELD FOR EMERGENCY.
Other Protective Equipment:DO NOT USE NEOPRENE RUB & POLYVINYL
CHLORIDE.IMPERV GOWNS,PLASTIC APRONS.RUBB BOOTS.
Work Hygienic Practices:WASH CONTAMIN CLOTH BEF REUSE;DISCARD CONTAMIN
LEATHER ARTICLES.AVOID CONTAMIN OF FOOD.
Supplemental Safety and Health
VAP DEN:1.05(GLUTARALDEHYDE). PH:7.5-8.1. APPEARANCE:ODOR MASKED W/MINT
FRAGRANCE. SYMP/SIGNS:INGEST:IRRIT/CHEM BURNS OF
MOUTH/THROAT/ESOPHAGUS/STOMACH,DISCOMFORT IN
MOUTH,THROAT/CHEST/ABDOMEN,NAU,VOM IT,DIARR,DIZZ,FAINTNESS,GENERAL
SYSTEMIC ILLNESS. 1STAID:DAMAGE FRM ORAL EXPO MAY CONTRAINDICATE
USE OF GASTRIC LAVAGE.

================== Physical/Chemical Properties ==================

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:16
Vapor Density:SUPPLEMENT
Spec Gravity:1.021G/CC
pH:SUPPLE
Evaporation Rate & Reference:0.98, H2O=1
Solubility in Water:COMPLETE (100%)
Appearance and Odor:2COMPONENTS:COLORLESS FLUID & LIQ SALTS,TURNS GREEN
WHEN ACTIVATED,SHARP (SUPPL

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALINE MATLS (PH>10) CATALYZE AN ALDOL-TYP CONDESATION WHICH
IS EXOTHERMIC BUT NOT EXPECTED TO BE VIOLENT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE(HIGHLY TOXIC IF INHAL)
&/OR CARBON DIOXIDE(SUFFIENT CONC CAN ACT AS ASPHYXIANT).

==================== Disposal Considerations ====================

Waste Disposal Methods:DISCARD RESIDUAL SOLN IN DRAIN.FLUSH WELL W/LG
AMT OF WATER.QT/GAL CNTNR RINSE EMPTY CNTNR WELL W/WATER;WRAP CNTNR
& PUT IN TRASH.DO NOT REUSE EMPTY CNTNR.2 1/2 GAL CNTNR RINSE EMPTY
WELL W/WATER & DI SPOSE IN INCINERATOR/LANDFILL FOR PESTICIDE
CNTNR.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
1201 RTV PRIME COAT 67-64-1
78-10-4
108-88-3
75-79-6
25766-16-9
GASOLINE,BP REGULAR UNLEADED OR GASOLINE,REGULAR UNLEADED 87 8006-61-9
108-88-3
1330-20-7
71-43-2
95-63-6
100-41-4
110-82-7
64-17-5
QUICK START CANISTER FOR CHEMOX OXYGEN BREATHING APPARATUS 12030-88-5
7775-09-9
1304-29-6
7778-74-7
ACTIVATOR A 111-40-0
AERO HFA
MIL-C-372 C AM 2 (RIFLE BORE CLEANER),3014601,F-4962 8008-20-6
61790-12-3
68608-26-4
64742-53-6
64742-52-5
REGULAR DRIERITE 7778-18-9
1317-65-3
CELATOM FW-50 68855-54-9
14464-46-1
SILICA FILLED DIMETHYLPOLYSILOXANE 112945-52-5
63148-62-9
ALLTREX 2 7697-37-2
3333-67-3
13598-37-3
VINYL ACRYLIC LATEX PAINT PRODUCTS 311-XX INTERIOR FLAT LATX 107-21-1
1336-21-6
BREATHING APPARATUS,OXYGEN GENERATING,MIL-B-51254(MU) 12030-88-5
7775-09-9
1304-29-6
7778-74-7
SPECTRACIDE,DIZOL,DIAZINON 333-41-5
8002-05-9
1330-20-7
SPOTCHECK CLEANER/REMOVER SKC-NF 71-55-6
109-87-5
75-65-0
HALON 1211 353-59-3
SN63 (SN63PB37) WRMAP3 7439-92-1
7440-31-5
8050-09-7
EXTREME PRESSURE LUBE #3 63231-60-7
65997-13-9
39464-64-7
ARCOS STAINLESS STEEL ALLOY 307 (COVERED WELDING ELECTRODES) 7439-89-6
7440-47-3
7439-96-5
7440-02-0
PACKAGED CHAFF (ALUMINIZED GLASS)
CHAFF,BUNDLE (ALUMINIZED GLASS) 71-43-2
67-56-1
64-17-5
108-10-1
A-C-D SOLUTION (MODIFIED) 77-92-9
50-99-7
68-04-2
7732-18-5
ISOPROPYL ALCOHOL,31110 67-63-0
PANTONE RUBBER BASE INK, 3-4430 64742-46-7
PANTONE RUBBER BASE INK, 3-4110 64742-46-7
PANTONE RUBBER BASE INK, 3-4510 64742-46-7
OFFSET ROLLER CLEANER AND BLANKET WASH P/N 4-4317 64742-48-9
CIDEX PLUS 28 DAY SOLN/ACTIVATOR VIAL PRODUCT CODE:2785 111-30-8
25322-68-3
7732-18-5
LITHIUM OXYHALIDE PRIMARY BATTERY (BCX) 7439-93-2
7719-09-7
7726-95-6
7782-50-5
CAUSTIC SODA LIQUID (ALL GRADES) 7732-18-5
1310-73-2
7647-14-5
7775-09-9
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-A #1505 1310-58-3
7757-83-7
10117-38-1
7775-19-1
123-31-9
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-B #1617 64-19-7
92-43-3
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-C #1721 111-30-8
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-D #1806 111-46-6
6400-6406 SERIES SEMI-GLOSS HIGH SOLID POLYURETHANE COMP 1 78-93-3
110-43-0
123-86-4
DISSOLVED OXYGEN CHEMETS,ULR CHEMETS AND VACU-VIALS,R-7501 111-46-6
7732-18-5
5 C CELL CONTROL,7547001
DARACLEAN 282
ALT KIT, PART A 26628-22-8
ALT KIT, PART B 119-26-6
7647-01-0
ALT KIT, PART C 127-17-3
54-64-8
26628-22-8
999 AP 7440-44-0
999-30, 999-1, 999-15
BLACK TONER FOR DC-PART NO (SEE SUPPLEMENTAL FOR PART NO.) 1333-86-4
31714-55-3
1344-28-1
25213-39-2
68611-44-9
9003-07-0
7350 BLACK TONER, 4129036; SAVIN CODES 7912, 7350 9002-88-4
25068-63-7
1333-86-4
64475-85-0
ANTISTATIC SCREEN CLEANER, TX1261 67-63-0
7664-41-7
68391-01-5
68956-79-6
COOL'R CLEAN'R HEAVY DUTY COMPLETE'R A 7664-38-2
BIO T PARTS WASH NR 5989-27-5
BIO T PARTS WASH NR 5989-27-5
BIO T 300B
BIO T 200A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net