Search   
MSDS  : FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-D #1806
CAS  : 111-46-6
NAME  : diethylene glycol
===================== Product Identification =====================

MSDS NAME:FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-D #1806
NIIN:01-318-9969
MSDS Number: BXFZH
=== Responsible Party ===
Company:FUJI NDT SYSTEMS
Address:1055 STEVENSON CRT
City:ROSELLE
State:IL
ZIP:60172-2300
Country:US
Info Phone Num:770-448-0250
Emergency Phone Num:770-448-0250
CAGE:NO425
=== Contractor Identification ===
Company:ALLIED PHOTO PRODUCT CO,SUB OF ALLIED PRODUCT CORP
Address:5440-A OAKBROOK PKY
Box:City:NORCROSS
State:GA
ZIP:30093-2251
Country:US
Phone:770-448-0250
CAGE:1CG79
Company:FUJI MEDICAL SYSTEMS INC FUJI NDT SYSTEMS DIV
Address:90 VIADUCT RD
City:STAMFORD
State:CT
ZIP:06907
Country:US
Phone:203-353-0300
CAGE:0CSD2
Company:FUJI NDT SYSTEMSDUCTS CO INC
Address:1055 STEVENSON CRTY
City:ROSELLE
State:IL
ZIP:60172-2300
Country:US
Phone:770-448-0250
CAGE:NO425

============= Composition/Information on Ingredients =============

Name:DIETHYLENE GLYCOL
CAS:111-46-6
RTECS #:ID5950000
Fraction by Wt: >99%
Other REC Limits:NONE RECOMMENDED

===================== Hazards Identification =====================

LD50 LC50 Mixture:LD50 ORAL RAT HAS NOT BEEN ESTABLISHED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: VAPOR MAY CAUSE IRRITATION
TO NOSE AND THROAT. EYES: VAPOR MAY CAUSE IRRITATION. CONTACT
CAUSES IRRITATION. SKIN: REPEATED AND PROLONGED CONTACT MAY CAUSE
IRRITATION. INGESTION: DO NOT TAK E INTERNALLY.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: SWALLOWING MAY CAUSE
GASTROINTESTINAL IRRITATION, NAUSEA, VOMITING, DIARRHEA, CENTRAL
NERVOUS DEPRESSION AND KIDNEY DAMAGE WHICH MAY BE FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:IF ON SKIN-THOROUGHLY WASH EXPOSED AREA WITH SOAP & WATER. IF
IN EYE-IMMEDIATELY FLUSH WAITH WATER, LIFTING UPPER & LOWER LIDS,
GET MEDICAL ATTENTION. IF SWALLOWED-IMMEDIATELY DRINK 2 GLASSES OF
WATER AND INDUCE VOMITING BY GIVING IPECAC SYRUP OR STICKING
FINGER AT BACK OF THROAT. GET MEDICAL ATTENTION IMMEDIATELY. IF
BREATHED-REMOVE INDIVIDUAL TO FRESH AIR.

===================== Fire Fighting Measures =====================

Flash Point:NONE
Extinguishing Media:USE METHOD APPROPIATE FOR SURROUNDING FIRE.RBON
DIOXIDE.
Fire Fighting Procedures:USE PROTECTIVE CLOTHING TO PREVENT CONTACT
WITH SKIN & EYES.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION, IT CAN EMIT
ACRID SMOKE AND FUMES. WILL PRODUCE PHOSPHORUS, CARBON DIOXIDE AND
POSSIBLY CARBON MONOXIDE.

================== Accidental Release Measures ==================

Spill Release Procedures:WEAR PROTECTIVE CLOTHING. NEUTRALIZE WITH
SODIUM BICARBONATE. IF FEDERAL, STATE AND LOCAL LAWS PERMIT, FLUSH
TO SEWER WITH LARGE AMOUNTS OF WATER.
Neutralizing Agent:SODIUM BICARBONATE

====================== Handling and Storage ======================

Handling and Storage Precautions:DON'T STORE OR CONSUME FOOD, DRINK,
TOBACCO IN SURROUNDING AREA. WASH THOROUGHLY AFTER USE.
Other Precautions:WASH THOROUGHLY AFTER USE.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:SHOULD NOT BE NECESSARY UNDER NORMAL CONDITIONS.
IF EXPOSED TO VAPORS THAT EXCEED TLV OR PEL, WEAR AN APPROVED VAPOR
RESPIRATOR.
Ventilation:GOOD LOCAL MECHANICAL VENTILATION SHOULD BE SUFFICIENT.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:WEAR PROTECTIVE GOGGLES.
Other Protective Equipment:AS NECESSARY TO PREVENT SKIN CONTACT. EYE
WASH FACILITIES IN VINCINITY OF USE.
Work Hygienic Practices:WASH THOROUGHLY AFTER USE.
Supplemental Safety and Health
KEY1;C3.

================== Physical/Chemical Properties ==================

HCC:C2
Boiling Pt:>100.C, 212.F
Vapor Pres:<0.01
Vapor Density:3.6
Spec Gravity:1.114
pH:4.4
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR.
Percent Volatiles by Volume:90%

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
MINERAL ACIDS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION, IT CAN
EMIT TOXIC FUMES OF SULFUR DIOXIDE.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSE OF CONTAMINATED PRODUCT/MATERIALS USED
IN CLEANING UP SPILL IN A MANNER APPROVED FOR THIS MATERIAL.
CONSULT PROPER FEDERAL, STATE AND LOCAL REGULATORY AGENCIES TO
ASCERTAIN PROPER DISPOSAL PRO CEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
1201 RTV PRIME COAT 67-64-1
78-10-4
108-88-3
75-79-6
25766-16-9
GASOLINE,BP REGULAR UNLEADED OR GASOLINE,REGULAR UNLEADED 87 8006-61-9
108-88-3
1330-20-7
71-43-2
95-63-6
100-41-4
110-82-7
64-17-5
QUICK START CANISTER FOR CHEMOX OXYGEN BREATHING APPARATUS 12030-88-5
7775-09-9
1304-29-6
7778-74-7
ACTIVATOR A 111-40-0
AERO HFA
MIL-C-372 C AM 2 (RIFLE BORE CLEANER),3014601,F-4962 8008-20-6
61790-12-3
68608-26-4
64742-53-6
64742-52-5
REGULAR DRIERITE 7778-18-9
1317-65-3
CELATOM FW-50 68855-54-9
14464-46-1
SILICA FILLED DIMETHYLPOLYSILOXANE 112945-52-5
63148-62-9
ALLTREX 2 7697-37-2
3333-67-3
13598-37-3
VINYL ACRYLIC LATEX PAINT PRODUCTS 311-XX INTERIOR FLAT LATX 107-21-1
1336-21-6
BREATHING APPARATUS,OXYGEN GENERATING,MIL-B-51254(MU) 12030-88-5
7775-09-9
1304-29-6
7778-74-7
SPECTRACIDE,DIZOL,DIAZINON 333-41-5
8002-05-9
1330-20-7
SPOTCHECK CLEANER/REMOVER SKC-NF 71-55-6
109-87-5
75-65-0
HALON 1211 353-59-3
SN63 (SN63PB37) WRMAP3 7439-92-1
7440-31-5
8050-09-7
EXTREME PRESSURE LUBE #3 63231-60-7
65997-13-9
39464-64-7
ARCOS STAINLESS STEEL ALLOY 307 (COVERED WELDING ELECTRODES) 7439-89-6
7440-47-3
7439-96-5
7440-02-0
PACKAGED CHAFF (ALUMINIZED GLASS)
CHAFF,BUNDLE (ALUMINIZED GLASS) 71-43-2
67-56-1
64-17-5
108-10-1
A-C-D SOLUTION (MODIFIED) 77-92-9
50-99-7
68-04-2
7732-18-5
ISOPROPYL ALCOHOL,31110 67-63-0
PANTONE RUBBER BASE INK, 3-4430 64742-46-7
PANTONE RUBBER BASE INK, 3-4110 64742-46-7
PANTONE RUBBER BASE INK, 3-4510 64742-46-7
OFFSET ROLLER CLEANER AND BLANKET WASH P/N 4-4317 64742-48-9
CIDEX PLUS 28 DAY SOLN/ACTIVATOR VIAL PRODUCT CODE:2785 111-30-8
25322-68-3
7732-18-5
LITHIUM OXYHALIDE PRIMARY BATTERY (BCX) 7439-93-2
7719-09-7
7726-95-6
7782-50-5
CAUSTIC SODA LIQUID (ALL GRADES) 7732-18-5
1310-73-2
7647-14-5
7775-09-9
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-A #1505 1310-58-3
7757-83-7
10117-38-1
7775-19-1
123-31-9
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-B #1617 64-19-7
92-43-3
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-C #1721 111-30-8
7732-18-5
FUJI AUDEL INDUSTRIAL X DEVELOPER, ITEM PT-D #1806 111-46-6
6400-6406 SERIES SEMI-GLOSS HIGH SOLID POLYURETHANE COMP 1 78-93-3
110-43-0
123-86-4
DISSOLVED OXYGEN CHEMETS,ULR CHEMETS AND VACU-VIALS,R-7501 111-46-6
7732-18-5
5 C CELL CONTROL,7547001
DARACLEAN 282
ALT KIT, PART A 26628-22-8
ALT KIT, PART B 119-26-6
7647-01-0
ALT KIT, PART C 127-17-3
54-64-8
26628-22-8
999 AP 7440-44-0
999-30, 999-1, 999-15
BLACK TONER FOR DC-PART NO (SEE SUPPLEMENTAL FOR PART NO.) 1333-86-4
31714-55-3
1344-28-1
25213-39-2
68611-44-9
9003-07-0
7350 BLACK TONER, 4129036; SAVIN CODES 7912, 7350 9002-88-4
25068-63-7
1333-86-4
64475-85-0
ANTISTATIC SCREEN CLEANER, TX1261 67-63-0
7664-41-7
68391-01-5
68956-79-6
COOL'R CLEAN'R HEAVY DUTY COMPLETE'R A 7664-38-2
BIO T PARTS WASH NR 5989-27-5
BIO T PARTS WASH NR 5989-27-5
BIO T 300B
BIO T 200A

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net