Spill Release Procedures:CONTAIN LEAKS TO PREVENT DISCHARGE INTO THE
ENVIRONMENT. VENTILATE AREA. SMALL: SOAK UP W/ABSORBENT, SHOVEL
INTO WASTE CONTAINER, FLUSH AREA W/WATER. LARGE: RECOVER LIQUID FOR
REPROCESSING/DISPOSAL.
Neutralizing Agent:NEUTRALIZE 1% AMMONIA
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A DRY, WELL VENTILATED AREA
AT ABOUT 65-85F. RELEASE PRESSURE CAREFULLY BEFORE OPENING
CONTAINERS.
Other Precautions:SPILLED MATERIAL IS SLIPPERY. EMPTY CONTAINER MAY
RETAIN VAPOR/PRODUCT RESIDUE. OBSERVE ALL LABELED SAFEGUARDS UNTIL
CONTAINER IS CLEANED, RECONDITIONED/DESTROYED.
Respiratory Protection:IF VAPORS ARE PRESENT, USE NIOSH/MSHA APPROVED
RESPIRATOR FOR ORGANIC VAPORS, AIR-LINE RESPIRATOR/A SCBA.
Ventilation:USE ADEQUATE VENTILATION TO KEEP HAZARDOUS INGREDIENTS <
TLV LIMITS.
Protective Gloves:IMPERVIOUS
Eye Protection:FULL FACE SHIELD/GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING, EYE WASH STATION &
SAFETY SHOWER.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
Waste Disposal Methods:RECOVER MATERIAL/DISPOSE (INCINERATION IS
PREFERRED). MATERIAL COLLECTED W/ABSORBENT MAY BE DISPOSED IN A
PERMITTED LANDFILL IAW/FEDERAL, STATE & LOCAL REGULATIONS. DON'T
POUR INTO DRAINS, AS SOLIDS T HAT FORM WILL PLUG SEWERS. NEUTRALIZE
W/AMMONIA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.