LD50 LC50 Mixture:ORAL LD50 (RAT) IS >5000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MINIMAL RESPIRATORY IRRITATION
MAY BE CAUSED BY INHALATION OF EXTREMELY LARGE AMOUNTS OF DUST.
CHRONIC: NONE SPECIFIED BY MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:COUGHING, SNEEZING, WHEEZING, SHORTNESS OF
BREATH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHALATION-WASH NOSTRILS, RINSE MOUTH. INGESTED-IF CONSCIOUS,
DILUTE STOMACH CONTENTS WITH SEVERAL GLASSES OF WATER. EYES-FLUSH
WITH WATER FOR 15 MINUTES. SKIN-WASH WITH SOAP & WATER.
===================== Fire Fighting Measures =====================
Lower Limits:N.AP.
Upper Limits:N.AP.
Extinguishing Media:WATER FOG, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:IF DISPERSED IN AIR, TONER, LIKE MOST
FINELY DIVIDED ORGANIC POWDERS, MAY FORM AN EXPLOSIVE MIXTURE.
Respiratory Protection:NONE NORMALLY REQUIRED WHEN USED AS INTENDED
WITH MINOLTA EQUIPMENT.
Ventilation:NONE NORMALLY REQUIRED WHEN USED AS INTENDED WITH MINOLTA
EQUIPMENT.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED WHEN USED AS INTENDED
WITH MINOLTA EQUIPMENT.
Work Hygienic Practices:NONE.
Supplemental Safety and Health
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION ARE TOXIC.
AVOID BREATHING OF SMOKE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Waste Disposal Methods:WASTE MAY BE DISPOSED OR INCINERATED UNDER
CONDITIONS WHICH MEET LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.