Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NITROGEN OXIDES-IRRITATION & BURNING.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NITROGEN OXIDES-IRRITATION, HEADACHE,
DIZZINESS, FALL IN BLOOD PRESSURE, CONGESTION IN NOSE & THROAT.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. OBTAIN MEDICAL ATTENTION IN
ALL CASES.
===================== Fire Fighting Measures =====================
Fire Fighting Procedures:DON'T FIGHT FIRE INVOLVING THIS UNIT.
Unusual Fire/Explosion Hazard:THIS UNIT CONTAINS HIGH ENERGY MATERIALS.
====================== Handling and Storage ======================
Handling and Storage Precautions:HANDLE W/CARE AVOIDING ELECTROSTATIC
DISCHARGE, HEAT & IMPACT. STORE IN DRY, MOISTURE FREE ENVIRONMENT.
Other Precautions:UNITS WHICH HAVE INCURRED SUBSTANTIAL IMPACT MAY
SUSTAIN INTERNAL DAMAGE. CONSULT W/TRA ENGINEERING STAFF FOR
EVALUATION.
Waste Disposal Methods:UNITS SHOULD BE DEACTIVATED BY A RCRA PERMITTED
FACILITY IAW/FEDERAL, STATE & LOCAL REGULATIONS. EPA WASTE CODE
D003. DETONATING FUSE UN0367.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.