LD50 LC50 Mixture:LD50 (ORAL RAT) IS 43,000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: NARCOSIS, CARDIAC
IRREGULARITIES, UNCONSCIOUSNESS OR DEATH. THE SURFACTANT IN THE
PRODUCT IS AN EYE IRRITANT.
Explanation of Carcinogenicity:NONE OF THE CHEMICALS IN THIS PRODUCT IS
LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:INHALATION: THE VAPOR IS HEAVIER THAN AIR AND
CAUSE SUFFOCATION BY REDUCING OXYGEN AVAILABLE FOR BREATHING.
BREATHING HIGH CONCENTRATIONS CAN CAUSE LIGHT-HEADEDNESS,
GIDDINESS, SHORTNESS OF BREATH. IR RITATION OF THE SKIN AND EYES.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF
RESPIRATORY DISORDERS MAY BE AT INCREASED RISK FROM EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE SUBJECT TO FRESH AIR. MAINTAIN BREATHING
AND SO NOT GIVE EPINEPHRINE OR SIMILAR DRUGS. EYE: FLUSH WITH
PLENTY OF WATER FOR 15 MINUTES. GET IMMEDIATE MEDICAL ATTENTION.
SKIN: WASH WI TH SOAP AND WATER. INGESTION: DO NOT INDUCE VOMITING.
GET IMMEDIATE MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:EXTINGUISH WITH AGENT SUITABLE FOR SURROUNDING FIRE
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE NOTED BY MANUFACTURER.
Spill Release Procedures:ISOLATE AREA.ELIMINATE IGNITION SOURCES. STOP
LEAK. PROVIDE VENTILATION. USE SELF-CONTONTAINED BREATHING
APPARATUS WHEN REQUIRED. COOL CONTAINR WITH WATER. ABSORB WITH
ABSORBENT.
Neutralizing Agent:NONE APPLICABLE FOR THIS MATERIAL
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL,DRY,WELL VENTILATED,LOW
FIRE RISK AREA.PROTECT CONTAINERS FROM PHYSICAL DAMAGE.STORE
CONTAINERS IN A CLEAN AREA.DO NOT HEAT ABOVE 125F.
Other Precautions:AVOID ANY PHYSICAL CONTACT.KEEP CONTAINERS TIGHTLY
CLOSED.FOR PERSONAL PROTECTION USE SAFETY GLASSES & WORKING
GLOVES.FOR FURTHER INFORMATION SEE FREON PRODUCT BULLETINS
FST-1,S-16,S-24,S-30.
Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
EXPOSURES BELOW PEL (TLV), USE NIOSH/MSHA APPROVED RESPIRATOR AS
PER CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS AND
NIOSH-RESPIRATOR SELECTION.
Ventilation:MECHANICAL (GENERAL) VENTILATION IS REQUIRED. LOCAL EXHAUST
MAY BE REQUIRED IF WORK AREA IS NOT VENTED.
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES
Other Protective Equipment:SAFETY SHOWER AND EYE BATH. OTHER EQUIPMENT
AS REQUIRED TO MINIMIZE EXPOSURE FROM PROLONGED OR REPEATED
CONTACT.
Work Hygienic Practices:WASH THROUGHLY AFTER HANDLING AND BEFORE
EATING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NONE
HCC:N1
Boiling Pt:B.P. Text:112F,44C
Vapor Pres:362
Vapor Density:2.9
Spec Gravity:1.49
pH:7.0
Evaporation Rate & Reference:SLOW (CCL4=1)
Appearance and Odor:CLEAR, PALE YELLOW LIQUID WITH FAINT SOLVENT ODOR.
Percent Volatiles by Volume:97.5
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS
Stability Condition to Avoid:OPEN FLAMES OR HIGH TEMPERATURES.
Hazardous Decomposition Products:THIS COMPOUND CAN BE DECOMPOSED BY
HIGH TEMPS. FORMING HYDROCHLORIC AND HYDROFLUORIC ACIDS, POSSIBLY
CARBONYL HALIDES.
Waste Disposal Methods:KEEP IN COVERED DRUMS,PENDING DISPOSAL.HANDLE &
DISPOSE IN FULL COMPLIANCE WITH ALL APPLICABLE
INTERNATIONAL,FEDERAL,STATE & LOCAL REGULATIONS.MFR
SUGGESTS"RECLAIM BY DISTILLATION"IF DUMPED INTO A LAN DFILL,IT MUST
BE AN APPROVED ONE IAW FED,STATE REG
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.