===================== Product Identification =====================
MSDS NAME:QUICKSEAM SPLICE TAPE(2 1/2"/3",408/9/92S)
NIIN:00F047166
MSDS Number: BZCLB
=== Responsible Party ===
Company:FIRESTONE BUILDING PRODUCTS CO
Address:525 CONGRESSIONAL BLVD
City:CARMEL
State:IN
ZIP:46032-5000
Country:US
Info Phone Num:615-231-3911/317-575-7190
Emergency Phone Num:615-231-3911/317-575-7190
CAGE:FIRES
=== Contractor Identification ===
Company:FIRESTONE BUILDING PRODUCTS CO
Address:525 CONGRESSIONAL BLVD
City:CARMEL
State:IN
ZIP:46032-5000
Country:US
Phone:615-231-3911
CAGE:FIRES
============= Composition/Information on Ingredients =============
Name:MBTS RUBBER ACCELERATOR
CAS:120-78-5
RTECS #:DL4550000
Fraction by Wt: <5%
Name:COLUMBIA CARBON, CARBON BLACK, LAMPBLACK, BLACK PEARLS
(IARC CARC GROUP 3) - *96-1*
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: <7%
Other REC Limits:3.5 MG/CUM (NIOSH)
OSHA PEL:3.5 MG/CUM
ACGIH TLV:3.5 MG/CUM
Name:LEAD PEROXIDE, LEAD DIOXIDE *96-1*
CAS:1309-60-0
RTECS #:OG0700000
Fraction by Wt: <3%
OSHA PEL:50 UG/CUM
ACGIH TLV:0.15 MG/CUM
Name:NON-HAZARDOUS INGREDIENTS
Fraction by Wt: >85%
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: MAY CAUSE ALLERGIC REACTION &
IRRITATION. HUMAN SYSTEMIC EFFECTS OF INORGANIC LEAD EXPOSURE BY
INGESTION & INHALATION INCLUDE GASTRIC & LIVER CHANGES. LEAD IS A
CUMULATIVE POSION EFFECTING THE N ERVOUS, GI, BLOOD SYSTEMS &
KIDNEYS. EXPOSURE TO LEAD CAN HAVE EFFECTS ON THE REPRODUCTIVE
FUNCTION OF BOTH MALE/FEMALE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION. INORGANIC LEAD: LOSS OF APPETITE,
ANEMIA, MALAISE, INSOMNIA, HEADACHE, IRRITABILITY, RESTLESSNESS,
FATIGUE, POOR MEMORY, DEPRESSION, MUSCLE & JOINT PAINS, WEAKNESS,
TREMORS, HALLUCINATIONS , DISTORTED PERCEPTIONS.
======================= First Aid Measures =======================
First Aid:WASH AREA THOROUGHLY W/SOAP & WATER. OBTAIN MEDICAL ATTENTION
IN ALL CASES.
===================== Fire Fighting Measures =====================
Flash Point:>446F
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:REGULAR FOAM/WATER FOG/CO2/DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA W/A FULL FACE PIECE OPERATED IN THE
POSITIVE PRESSURE DEMAND MODE.
====================== Handling and Storage ======================
Handling and Storage Precautions:NO SPECIAL REQUIREMENTS ARE
ANTICIPATED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Ventilation:NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Protective Gloves:NOT REQUIRED UNDER NORMAL CONDITIONS.
Eye Protection:NOT REQUIRED UNDER NORMAL CONDITIONS.
Other Protective Equipment:NORMAL WORK CLOTHING COVERING ARMS & LEGS.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:NONE
Spec Gravity:0.88-0.98
Solubility in Water:INSOLUBLE
Appearance and Odor:STICKY BLACK STRIP, ODORLESS
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Hazardous Decomposition Products:COMBUSTION PRODUCTS: CO2, CO, VARIOUS
HYDROCARBONS, PHENOLS, LEAD OXIDE FUMES, ZINC OXIDE FUMES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|