===================== Product Identification =====================
MSDS NAME:POTASSIUM IODATE
NIIN:00-185-6971
MSDS Number: BDGYX
=== Responsible Party ===
Company:SPECTRUM CHEMICAL MFG.CORP.
Address:14422 S. SAN PEDRO ST.
City:GARDENA
State:CA
ZIP:90248-9985
Country:US
Info Phone Num:213-516-8000
Emergency Phone Num:213-516-8000
Chemtrec Ind/Phone:(800)424-9300
CAGE:63415
=== Contractor Identification ===
Company:CHEMICAL COMMODITIES AGENCY, INC.
Address:27447 PACIFIC STREET
Box:City:HIGHLAND
State:CA
ZIP:92346-2640
Country:US
Phone:909-864-2310
CAGE:60777
Company:SPECTRUM LABORATORY PRODUCTS INC
Address:14422 S SAN PEDRO ST
Box:City:GARDENA
State:CA
ZIP:90248-2027
Country:US
Phone:310-516-8000/FAX: 310-516-9843
CAGE:63415
============= Composition/Information on Ingredients =============
Name:POTASSIUM IODATE
CAS:7758-05-6
RTECS #:NN1350000
Fraction by Wt: 100%
===================== Hazards Identification =====================
LD50 LC50 Mixture:IPR MOUSE 136 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY BE IRRITATING TO EYES,SKIN,MUCOUS
MEMBRANES.
Effects of Overexposure:EYE: IRRITATION. SKIN: MAY BE IRRITATING.
INHALED: IRRITATING TO RESPIRATORY TRACT. INGESTED: NO HUMAN DATA.
PRODUCED EMESIS IN DOGS.
Medical Cond Aggravated by Exposure:NONE LISTED BY MFR.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER. SKIN:WASH WITH SOAP & WATER.
INHALED:REMOVE FROM EXPOSURE. GIVE OXYGEN OR CPR IF NEEDED. GET
MEDICAL ATTENTION. INGESTED:NO SPECIFIC ANTIDOTE. GIVE WATER AND
INDUCE VOMITING. GET IMMEDIATE MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS. MOVE
CONTAINERS FROM FIRE IF POSSIBLE.
Unusual Fire/Explosion Hazard:OXIDIZER. THERE IS VERY LITTLE HAZARD DUE
TO HEAT OR FLAME IF COMBUSTIBLES ARE ABSENT.
================== Accidental Release Measures ==================
Spill Release Procedures:NO SPECIAL PRECAUTIONS REPORTED BY MFR. HMIS:
AVOID CONTACT WITH INCOMPATABLES DURING CLEAN-UP.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY AREA, AWAY FROM
ORGANICS, COMBUSTIBLES, ETC. (SEE INCOMPATABLES)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH RESPIRATOR FOR DUSTS AND HALOGENS OR
SUPPLIED AIR RESPIRATOR IF EXPOSED ABOVE TLV FOR NUISANCE DUSTS.
Ventilation:USE LOCAL EXHAUST IF NECESSARY TO REDUCE EXPOSURE
Protective Gloves:RUBBER/PLASTIC TO PREVENT SKIN CONTACT
Eye Protection:SPLASH/DUST PROOF GOGGLES
Other Protective Equipment:NO SPECIAL CLOTHING. EYE WASH AND SAFETY
SHOWER
Work Hygienic Practices:USE NORMAL CHEMICAL HYGIENE PRACTICES.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:D1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:=100.C, 212.F
B.P. Text:WATER BOILS
Melt/Freeze Pt:=560.C, ######F
Decomp Temp:=100.C, 212.F
Decomp Text:LOOSES WATER
Spec Gravity:3.930
Solubility in Water:4.74GM
Appearance and Odor:COLORLESS TO WHITE CRYSTALS OR CRYSTALLINE POWDER,
NO ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
REACTIVE METALS,CARBON,ORGANICS,REDUCING
AGENTS,SULFUR,COPPER,ARSENIC,PHOSPHORUS
Stability Condition to Avoid:NONE REPORTED BY MFR.
Hazardous Decomposition Products:HYDROGEN IODIDE, POTASSIUM OXIDE
FUMES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|