MSDS   | : | BORON NITRIDE SPRAY | CAS   | : | 10043-11-5 68953-58-2 64-17-5 67-56-1 108-88-3 75-09-2 75-28-5 | NAME   | : | cubic boron nitride, boron potassium nitrate *96-2* quaternary ammonium compounds, bis(hydrogenated tallow ethanol (ethyl alcohol), tecsol, alcohol, synasol methanol (methyl alcohol), columbian spirits *96-2* toluene (iarc carc- group 3) *96-2* dichloromethane (methylene chloride) (susp human carc by isobutane, 2-methylpropane
|
| |
|
|
===================== Product Identification =====================
MSDS NAME:BORON NITRIDE SPRAY
NIIN:00F048269
MSDS Number: BZFFV
=== Responsible Party ===
Company:ADVANCED CERAMICS CORP
Address:11907 MADISON AVE
City:LAKEWOOD
State:OH
ZIP:44107-5000
Country:US
Info Phone Num:216-529-3900/216-529-3925
Emergency Phone Num:216-529-3900/216-529-3925
CAGE:01VA7
=== Contractor Identification ===
Company:ADVANCED CERAMICS CORP
Address:11907 MADISON AVE
City:LAKEWOOD
State:OH
ZIP:44107-5000
Country:US
Phone:216-529-3900/216-529-3925
CAGE:01VA7
============= Composition/Information on Ingredients =============
Name:CUBIC BORON NITRIDE, BORON POTASSIUM NITRATE *96-2*
CAS:10043-11-5
Fraction by Wt: <5%
Name:QUATERNARY AMMONIUM COMPOUNDS, BIS(HYDROGENATED TALLOW
ALKYL) DIMETHYLAMMONIUM BENTONITE *96-2*
CAS:68953-58-2
RTECS #:UZ2996400
Fraction by Wt: <1%
Name:ETHANOL (ETHYL ALCOHOL), TECSOL, ALCOHOL, SYNASOL
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: <5%
Other REC Limits:1900 MG/CUM
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
Name:METHANOL (METHYL ALCOHOL), COLUMBIAN SPIRITS *96-2*
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: <4%
Other REC Limits:200 PPM
OSHA PEL:200 PPM
ACGIH TLV:200 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:TOLUENE (IARC CARC- GROUP 3) *96-2*
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: <5%
Other REC Limits:375 MG/CUM
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:DICHLOROMETHANE (METHYLENE CHLORIDE) (SUSP HUMAN CARC BY
ACGIH, SUSP ANIM CARC BY IARC; NTP - IARC GROUP 2B) *96-2*
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: >45%
ACGIH TLV:174 MG/CUM (A2)
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:ISOBUTANE, 2-METHYLPROPANE
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: >35%
Other REC Limits:1000 PPM
OSHA PEL:1800 MG/CUM
ACGIH TLV:1000 PPM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:OVEREXPOSURE: IRRITATION OF EYES, SKIN
& RESPIRATORY SYSTEM. MAY CAUSE NERVOUSNESS & POSSIBLY DEATH.
METHYLENE CHLORIDE CAN RAISE THE LEVEL OF CO IN THE BLOOD.
Explanation of Carcinogenicity:SEE INGREDIENTS
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, LOSS OF
COORDINATION, REDNESS, ITCHING, BURNING.
Medical Cond Aggravated by Exposure:OVEREXPOSURE TO METHYLENE CHLORIDE:
CARDIOVASCULAR PROBLEMS.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. KEEP WARM
& QUIET. SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH W/LARGE
AMOUNTS OF WATER FOR 15 MINS. INGESTION: NEVER GIVE ANYTHING BY
MOUTH T O AN UNCONSCIOUS PERSON. GIVE CONSCIOUSPERSON SEVERAL
GLASSES OF WATER. IF VOMITING ISN'T SPONTANEOUS, INDUCE VOMITING BY
GENTLY TOUCHING BACK OF THROAT W/FINGER. KEEP AIRWAY CLEAR. (SEE
SUPP)
===================== Fire Fighting Measures =====================
Flash Point:<0F PROPELLANT
Lower Limits:1 BUTANE
Upper Limits:36.5 BUTANE
Extinguishing Media:SOLVENTS & PROPELLANTS: CO2, DRY CHEMICAL/FOAM.
Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT INCLUDING SCBA.
WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE
PREFERABLE. COOL CLOSED CONTAINERS W/WATER.
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT & OTHER IGNITION
SOURCES. CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME
HEAT. USE SPECIAL PRECAUTIONS W/HOT SURFACES.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE IGNITION SOURCES. VENTILATE & REMOVE
W/INERT ABSORBENT.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP FROM HEAT & OTHER IGNITION
SOURCES. VENTILATE AREA. DON'T SMOKE. EXTINGUISH FLAMES & OTHER
SOURCES OF HEAT. USE BOND & GROUNDING PROCEDURES.
Other Precautions:CONTENTS UNDER PRESSURE. DON'T PUNCTURE,
INCINERATE/EXPOSE TO TEMP >120F. HEAT FROM SUNLIGHT, RADIATORS &
OTHER HEAT SOURCES COULD CAUSE CONTAINER TO BURST. DON'T TAKE
INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF EXPOSURE CAN'T BE CONTROLLED BELOW APPLICABLE
LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF
EXPOSURES IS BELOW APPLICABLE LIMITS.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SAFETY SPECTACLES
Other Protective Equipment:SAFETY SPECTACLES W/UNPERFORATED
SIDESHIELDS.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:10-238F
Spec Gravity:7.1
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:DRIED COATING IS WHITE, ODORLESS, NONFLAMMABLE.
Percent Volatiles by Volume:>80
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT & OTHER IGNITION SOURCES, TEMP >120F,
SUNLIGHT, RADIATORS, STOVES.
Hazardous Decomposition Products:FIRE: CO2, CO, HYDROGEN CHLORIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE MAY BE HAZARDOUS AS DEFINED BY RESOURCE
CONSERVATION & RECOVERY ACT, MUST BE TESTED FOR IGNITABILITY. DON'T
INCINERATE. DEPRESSURIZE CONTAINER. DISPOSE OF IAW/FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|