===================== Product Identification =====================
MSDS NAME:IMRON 5000 POLYURETHANE ENAMELS, 527H
NIIN:00N073995
MSDS Number: CCRHL
=== Responsible Party ===
Company:E I DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:0ERJ7
=== Contractor Identification ===
Company:E I DUPONT DE NEMOURS & CO, INC.
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515
CAGE:0ERJ7
Company:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Name:ACRYLIC POLYMER A
CAS:42767-92-0
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ACRYLIC POLYMER B
CAS:42767-92-0
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ACRYLIC POLYMER C
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ACETIC ACID, BUTYL ESTER; (BUTYL ACETATE) (CERCLA) VP:8.0 @
20C
CAS:123-86-4
RTECS #:AF7350000
OSHA PEL:150 PPM
ACGIH TLV:150 PPM/200STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:2-HEPTANONE; (METHYL AMYL KETONE) VP:2.2 @ 20C
CAS:110-43-0
RTECS #:MJ5075000
OSHA PEL:100 PPM
ACGIH TLV:50 PPM
Name:3,4,9,10-PERYLENETETRA-CARBOXYLIC DIANHYDRIDE; (PERYLENE
PIGMENT)
CAS:128-69-8
OSHA PEL:N/K
ACGIH TLV:10 MG/M3 (MFR)
Name:ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER; (PROPYLENE
GLYCOL MONOMETHYL ETHER ACETATE) VP:3.7 @ 20C
CAS:108-65-6
RTECS #:AI8925000
OSHA PEL:N/K
ACGIH TLV:N/K
Name:TOLUENE (SARA 313) (CERCLA) VP:36.7 @ 20C
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 3%
OSHA PEL:200 PPM
ACGIH TLV:S, 50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:XYLENE (SARA 313) (CERCLA) VP:25.0 @ 20C
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 1%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/150STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:SUPDAT:THIS PROD. DO NOT PERMIT ANYONE W/OUT PROT IN
PAINTING AREA. FOLLOW RESP MFR'S DIRECTIONS FOR RESP USE.
RTECS #:9999999ZZ
Name:EFTS OF OVEREXP:HAS BEEN INCONCLUSIVE. HAS BEEN TOX TO
FETUS IN LAB ANIMALS @ DOSES THAT ARE TOX TO MOTHER. (ING 13)
RTECS #:9999999ZZ
Name:METHYL AMYL KETONE:INGEST STUDIES ON LAB ANIMALS SHOWED
THAT VERY HIGH ORAL DOSES CAUSED INCRD LIVER & KIDNEY (ING 14)
RTECS #:9999999ZZ
Name:ING 13:WEIGHTS. PROPYLENE GLYCOL MONOMETHYL ETHER
ACETATE:MAY CAUSE MOD EYE BURNING. RECURRENT OVEREXP MAY RSLT (ING
15)
RTECS #:9999999ZZ
Name:ING 14:IN LIVER & KIDNEY INJURY. TOLUENE APPEARS ON NAVY
OCCUP CHEM REPRO HAZ LIST. SEEK CONSULTATION FROM (ING 16)
RTECS #:9999999ZZ
Name:ING 15:APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST
INFO & SAFE HNDLG & USE INFO . RECURRENT (ING 17)
RTECS #:9999999ZZ
Name:ING 16:OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. HIGH
AIRBORNE LEVELS HAVE PRDCED IRREG HEART BEATS IN ANIMALS (ING 18)
RTECS #:9999999ZZ
Name:ING 17:& OCCAS PALPITATIONS IN HUMANS. RATS EXPOSED TO VERY
HIGH AIRBORNE LEVELS HAVE EXHIBITED HIGH FREQUENCY (ING 19)
RTECS #:9999999ZZ
Name:ING 18:HEARING DEFICITS. SIGNIFICANCE OF THIS TO MAN IS
UNKNOWN. XYLENE:HIGH CONC HAVE CAUSED EMBRYOTOX EFTS IN (ING 20)
RTECS #:9999999ZZ
Name:ING 19:LAB ANIMALS. RECURRENT OVEREXP MAY RSLT IN LIVER &
KIDNEY INJURY. CAN BE ABSORBED THRU SKIN IN HARMFUL AMTS.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:GI DISTRESS. INHAL:MAY CAUSE
NOSE & THROAT IRRIT. RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD TO
PERM BRAIN & NERV SYS DMG. EYE WATERING, HDCHS, NAUS, DIZZ & LOSS
OF COORD ARE SIGNS THAT SOLV LEVEL S ARE TOO HIGH. EXPOS TO
ISOCYANATES MAY CAUSE RESP SENSIT. EFTS MAY BE PERM. EFT MAY BE
DELAYED FOR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:SEVERAL HRS AFTER EXPOS. RPTD OVEREXP
TO ISOCYANATES MAY CAUSE DECR IN LUNG FUNCTION WHICH MAY BE PERM.
SKIN/EYE CONT:MAY CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT
MAY CAUSE SKIN IRR IT W/DISCOMFORT & DERM. BUTYL ACETATE:MAY CAUSE
ABNORMAL LIVER FUNCTION. TESTS FOR EMBRYOTOX ACTIVITY IN
ANIMALS(ING 12)
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH BREATHING PROBLEMS
OR PRIOR REACTION TO ISOCYANATES MUST NOT BE EXPOSED TO VAPORS OR
SPRAY MIST OF THIS PRODUCT.
======================= First Aid Measures =======================
First Aid:INGESTION:IN THE UNLIKELY EVENT OF INGESTION CALL MD IMMED &
HAVE NAMES OF INGREDIENTS AVAILABLE. INHALATION:IF AFFECTED BY
INHALATION OF VAPOR/SPRAY MIST, REMOVE TO FRESH AIR. IF BREATHING
DIFFICULTY PERSISTS/OCCURS LATER, CONSULT MD. EYES:IMMEDIATELY
FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINUTES; CALL MD. SKIN:WASH
WITH SOAP AND WATER. IF IRRITATION OCCURS, CONTACT MD.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:100F,38C
Lower Limits:0.9%
Upper Limits:23.0%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILDUP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAMMABLE VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAM @ TEMPS BELOW FLASH POINT.
================== Accidental Release Measures ==================
Spill Release Procedures:DO NOT BRTHE VAPS, GET IN EYES/ON SKIN. WEAR
POS PRESS SUPP AIR VAP/PARTICULATE RESP (NIOSH TC-19C APPRVD), EYE
PROT, GLOVES & PROT MATL. REMOVE SOURCES OF IGNIT. ABSORB W/INERT
MATL. VENT AREA. POUR LIQ DECONTAM SOLN OVER SPILL & ALLOW
TO(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING.
Other Precautions:DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT,
BRAZE OR WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR
APPROPRIATE VENTILATION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DO NOT BRTHE VAPS/MISTS. WEAR POS PRESS SUPP AIR
RESP (NIOSH (TC-19C)/APPRVD) WHILE MIXING ACTIVATOR W/ANY
PAINT/CLEAR ENAMEL, DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS
ARE EXHSTED. INDIVIDUALS W/HISTORY OF LUNG/BRTHG PROBLEMS(SUPDAT)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES ARE RECOMMENDED.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
SPILL PROC:SIT 10 MIN, MIN. TYPICAL DECONTAM SOLNS ARE:20% SURFACTANT
(TERGITOL TMN 10), 80% WATER, 0-10% AMMONIA, 2-5% DETERGENT,
BALANCE WATER. THIS PROCEDURE CAN GENERATE PRESS. DO NOT SEAL
CNTNR. AFTER 48 HRS, CNTNR MAY BE SEALED & DISP OF. RESP PROT:OR
PRIOR RXN TO ISOCYANATE SHOULD NOT USE/BE EXPOSED TO (ING 11)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>135F,>57C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.06
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:7-100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS IN HAZARDOUS INGREDIENTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE CLOSED
CONTAINERS.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|