===================== Product Identification =====================
MSDS NAME:SNAP WRAP INSULATION
NIIN:00N077037
MSDS Number: CDMHB
=== Responsible Party ===
Company:CERTAINTEED CORP
Box:860
City:VALLEY FORGE
State:PA
ZIP:19482-0101
Country:US
Info Phone Num:215-341-7000
Emergency Phone Num:215-341-7677
CAGE:CERTA
=== Contractor Identification ===
Company:CERTAIN-TEED CORP
Address:750 E SWEDESFORD RD
Box:860
City:VALLEY FORGE
State:PA
ZIP:19482
Country:US
Phone:215-341-7806
CAGE:89638
Company:CERTAINTEED CORP
Box:860
City:VALLEY FORGE
State:PA
ZIP:19482
Phone:(215) 341-7000
CAGE:CERTA
============= Composition/Information on Ingredients =============
Name:FIBROUS GLASS; (FIBERGLASS). BP:>2550F,>1399C. SPEC
GRAV:2.5 (H*2O=1). MP:2550F,1399C.
RTECS #:LK3651000
Fraction by Wt: 58.97%
Other REC Limits:5 MG/M3 (MFR)
OSHA PEL:15 MG/M3 (MFR)
ACGIH TLV:10 MG/M3 (DUST)
Name:UREA EXTENDED PHENOL-FORMALDEHYDE RESIN CURED; (UREA,
POLYMER W/FORMALDEHYDE AND PHENOL (CURED))
CAS:25104-55-6
Fraction by Wt: 3-17%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ACETIC ACID ETHENYL ESTER POLYMER WITH ETHENE (PRODUCT MAY
CONTAIN THIS INGREDIENT)
CAS:24937-78-8
Fraction by Wt: 11% MAX
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT:THERMALLY DECOMP AT ABOUT 250C(500F) & RELS HYDROGEN
CHLORIDE. AWJ JACKETING ON PIPE INSULATION WILL BEGIN(ING 5)
RTECS #:9999999ZZ
Name:ING 4:TO THERMALLY DECOMP AT ABOUT 175-200C (350-400F) RELS
HYDROGEN CHLORIDE & AT ABOUT 300-350C (570-660F) RELS(ING 6)
RTECS #:9999999ZZ
Name:ING 5:HYDROGEN FLUORIDE. IN FIRE SITUATION, CARBON
MONOXIDE, CARBON DIOXIDE, HYROGEN CHLORIDE, HYDROGEN FLUORIDE (ING
7)
RTECS #:9999999ZZ
Name:ING 6:& SULFUR DIOXIDE MAY ALSO BE FORMED.
RTECS #:9999999ZZ
Name:EFTS OF OVEREXP:IS OF LITTLE PRACTICAL SIGNIFICANCE" & WAS
SUPPORTED BY ANALYSIS OF DURATION OF EMPLOYMENT & (ING 9)
RTECS #:9999999ZZ
Name:ING 8:EXPOS TO MAN-MADE VITREOUS FIBER. SM STUDY OF
CANADIAN GLASS WOOL PLANT WORKERS REPORTED STATISTICALLY (ING 10)
RTECS #:9999999ZZ
Name:ING 8:SIGNIFICANT INCR IN LUNG CANCER DEATHS.
INTERPRETATION OF INFO ON THIS INCR WAS DFCLT SINCE THERE WAS NO
(ING 11)
RTECS #:9999999ZZ
Name:ING 10:RELATIONSHIP BTWN EXCESS LUNG CANCER & LGTH OF TIME
SINCE FIRST EXPOS. SUCH RELATIONSHIP WOULD BE (ING 12)
RTECS #:9999999ZZ
Name:ING 11:EXPECTED IF EXCESS IS RELATED TO ANY FACTORS IN WORK
ENVIRON. BASED LARGELY ON ANIMAL INPLANTATION EXPTS (ING 13)
RTECS #:9999999ZZ
Name:ING 12:& FOLLOWING ITS MANDATORY CLASSIFICATION PROTOCOL,
IARC CLASSIFIED GLASS WOOL AS CATEGORY 2B, "POSSIBLY (ING 14)
RTECS #:9999999ZZ
Name:ING 13:CARCIN TO HUMANS". FIBER GLASS IS LISTED ON
CALIFORNIA PROP 65 (CALIFORNIA SAFE DRINKING WATER & TOXIC (ING 15)
RTECS #:9999999ZZ
Name:ING 14:ENFORCEMENT ACT OF 1986).
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EXPOS TO FIBER GLASS MAY CAUSE
TEMPORARY SKIN, EYE & UPPER RESP IRRIT. CHRONIC:EXTENSIVE
MED-SCIENTIFIC RESEARCH HAS BEEN CONDUCTED REGARDING HLTH ASPECTS
OF FIBER GLASS OVER PAST 50 YRS. IARC, REVIEWED ALL SIGNIFICANT
RESEARCH ON HLTH EFTS ATTRIBUTED TO FIBER GLASS. IN ANIMAL EXPTS IN
WHICH (EFTS OF OVEREXP)
Explanation of Carcinogenicity:GLASS WOOL: IARC GROUP 2B, VOL43,P 152,
1988
Effects of Overexposure:HLTH HAZ:GLASS WOOL FIBERS WERE ARTIFICIALLY
INJECTED/SURGICALLY IMPLANTED IN ANIMALS' LUNGS, TUMORS WERE PRDCD.
SUCH PROCS BY-PASSED NORMAL BODY DEFENSE MECHS. EPIDEMIOLOGY STUDY
OF 11,380 MAN-MADE V ITROUS WORKERS REVEALED SM STATISTICAL
SIGNIFICANT EXCESS IN RESP CANCER. "12% EXCESS IN RESP CANCER
MORTALITY (ING 8)
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS WHICH MAY
BE AGGRAVATED BY MECHANICAL IRRITANTS UPON INHALATION OR SKIN
CONTACT.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE FROM EXPOSURE TO FRESH AIR, ADMINISTER OXYGEN.
GET MEDICAL HELP IF IRRITATION PERSISTS. EYES:FLUSH WELL W/RUNNING
WATER FOR AT LEAST 15 MINUTES. GET MEDICAL HELP IF IRRITATION
PERSISTS. S KIN:CLEANSE W/SOAP & WATER. GET MEDICALHELP IF
IRRITATION PERSISTS. INGEST:CONSULT MD IF UNUSUAL REACTION IS
NOTED. NOTE TO MD:SKIN IRRITATION RESPONDS WELL TO MILD
HYDROCORTISONE CREAM.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE THAT WHICH IS APPLICABLE TO SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . TREAT AS RESIDENTIAL BUILDING MATERIALS.
Unusual Fire/Explosion Hazard:FACINGS ON PRODS MAY BURN. CARE SHOULD BE
TAKEN TO NOT LEAVE FACING EXPOS WHEN WORKING CLOSE TO OPEN FLAME.
PRODS CNTN CURED PHENOLIC-BASED BINDER.
================== Accidental Release Measures ==================
Spill Release Procedures:SPILLS:VACUUM DUST DEPOSITS.
ACCIDENTAL/UNPLANNED RELEASES:CLEAN AREA W/VACUUM OR WET METHODS.
STORAGE:STORE UNDER COVER TO PROTECT PRODUCT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID SPREAD OF FIBER GLASS DUST.
WARNING:CONTAINS FIBER GLASS WOOL, A POSSIBLE CAUSE OF CANCER IF
INHALED, MAY CAUSE SKIN, EYE & RESPIRATORY IRRIT.
Other Precautions:FOR ADDITIONAL PRODUCT SAFETY INFORMATION, INCLUDING
NIOSH APPROVED DUST RESPIRATOR DATA & MSDS'S, CALL (215)341-7677.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR NIOSH APPRVD RESPS WHEN HNDLG & APPLYING
FIBER GLASS INSULATION PRODS I/A/W FOLLOWING NIOSH-BASED EXPOS
GUIDELINES: EXPOS:<10 X REL-3M8710/3M9900 (OR EQUIV); <50 X REL-MSA
ULTRA TWIN FILL FACE RE SP W/TYPE II FILTER (HEPA) (OR EQUIV).
Ventilation:PROVIDE GENERAL &/OR LOCAL EXHAUST VENTILATION TO CONTROL
AIRBORNE DUST LEVELS BELOW EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR LONG SLEEVES & CAP.
Work Hygienic Practices:AFTER HNDLG &/OR APPLYING THIS INSULATION:BATHE
W/SOAP & WARM WATER; WASH WORK CLOTHES SEPARATELY & RINSE
WASHER(SUPDAT)
Supplemental Safety and Health
APPEAR/ODOR:BOARDS. PRODS MAY BE FACED W/KRAFT, ALUMINUM FOIL,
VINYL/COMBINATION THEREOF. SOME PRODS MAY HAVE COATING. EYE PROT:&
FULL LGTH FCSHLD . HYGIENE PRACT:AFTER USE. HAZ DECOMP PROD:MOLE
CULAR FRAGMENTS OF HYDROCARBON PARTICULATES,
CARBON-HYDROGEN-NITROGEN & NITROGEN-OXYG CMPDS. VINYL FACINGS MAY
(ING 4)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:SEE ING 1
Melt/Freeze Pt:M.P/F.P Text:SEE ING 1
Spec Gravity:SEE ING 1
Solubility in Water:SMALL
Appearance and Odor:YELLOW COLOR; FAINT RESIN ODOR. FIBERS ASSEMBLED
INTO TUBES, BLANKETS/ (SUPDAT)
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BINDER & KRAFT FACING IN FIRE
SITUATION MAY EMIT TOX FUMES & SMOKE CNTNG CARBON DIOXIDE, CARBON
MONOXIDE & (SUPP DATA)
==================== Disposal Considerations ====================
Waste Disposal Methods:SCRAP MATERIAL SHOULD BE DISPOSED OF IN A
SANITARY LANDFILL I/A/W FEDERAL, STATE & LOCAL REGULATIONS. WASTE
IS NOT HAZARDOUS AS DEFINED BY RCRA (40 CFR 261).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|