Search   
MSDS  
:
 PLASTIC ROOF CEMENT, 204
CAS  
:
 64742-88-7
12001-29-5
NAME  
:
 solvent naphtha (petroleum) medium aliphatic; (petroleum
asbestos, chrysotile; (chrysotile (white) asbestos)
volatile organic compounds: 300 g/l max.
=====================  Product Identification  =====================

MSDS NAME:PLASTIC ROOF CEMENT, 204
NIIN:01-013-0626
MSDS Number: CDMKH
=== Responsible Party ===
Company:W W HENRY CO
Address:2911 SLAUSON AVE
City:HUNTINGTON PARK
State:CA
ZIP:90255
Country:US
Info Phone Num:213-583-5000
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:EO927
=== Contractor Identification ===
Company:HENRY W W CO
Box:3001
City:LANCASTER
State:PA
ZIP:17604
Country:US
Phone:717-396-2328;717-396-2935
CAGE:11761
Company:W W HENRY CO
Address:5608 SOTO ST
City:HUNTINGTON PARK
State:CA
ZIP:90255-5000
Country:US
Phone:213-583-4961
CAGE:EO927

=============  Composition/Information on Ingredients  =============

Name:SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (PETROLEUM
    DISTILLATE). VP:10 @ 60F.
CAS:64742-88-7
Fraction by Wt: 20-25%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:500 PPM (MFR)

Name:ASBESTOS, CHRYSOTILE; (CHRYSOTILE (WHITE) ASBESTOS)
CAS:12001-29-5
RTECS #:CI6478500
Fraction by Wt: 12-14%
OSHA PEL:0.2 FIBERS/CC
ACGIH TLV:2 FIBERS/CC

Name:VOLATILE ORGANIC COMPOUNDS: 300 G/L MAX.
RTECS #:9999999VO

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:HEADACHE, NAUSEA, GIDDINESS AND
    UNCONSCIOUSNESS, IRRITATION OF NOSE, THROAT AND EYES. EXTREME
    EXPOSURE MAY CAUSE DEATH BY PARALYSIS OF RESPIRATORY CENTER. IARC
    REPORTING ON MICE PAINTING STUDIES STATE S THAT THERE IS SUFFICIENT
    EVIDENCE FORCARCINOGENICITY IN EXPERIMENTAL ANIMALS OF EXTRACTS OF
    SOME (EFTS OF OVEREXP)
Explanation of Carcinogenicity:ASBESTOS, CHRYSOTILE:IARC MONOGRAPHS,
    SUPP, VOL 7, PG 106, 1987:GRP 1. NTP 7TH ANNUAL RPT ON CARCINS,
    1994:KNOWN(SUPDAT)
Effects of Overexposure:HLTH HAZ:ASPHALTS. THE SAME DOCUMENT STATES
    THAT THERE IS INADEQUATE EVIDENCE THAT ASPHALTS ALONE ARE
    CARCINOGENIC TO HUMANS.
Medical Cond Aggravated by Exposure:CURRENT ANEMIA, RESPIRATORY OR
    LIVER AILMENT.

=======================  First Aid Measures  =======================

First Aid:SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . REMOVE
    CONTAMINATED CLOTHING. INHAL:MOVE PERSON TO FRESH AIR. APPLY
    ARTIFICIAL RESPIRATION IF NEEDED. EYES:WASH W/WATER FOR AT LEAST 15
    MINUTES.  INGEST:DO NOT INDUCE VOMITING. CALL MD!

=====================  Fire Fighting Measures  =====================

Flash Point:120F,49C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUSTIBLE. OSHA: II.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EXTINGUISH ALL SOURCES OF IGNITION IN AREA.
    CLEAN UP SPILLS AS SOON AS POSSIBLE W/ABSORPTIVE MATERIAL SUCH AS
    CLAY, DIATOMACEOUS EARTH OR OTHER NON-FLAMMABLE ABSORBENTS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AWAY FROM SOURCES OF IGNITION.
    AVOID HEAT.
Other Precautions:COMBUSTIBLE LIQUID. ASBESTOS FIBERS, A REPORTED
    CARCINOGEN IN RESPIRATORY TRACT, ARE COMPLETELY ENCAPSULATED BY
    ASPHALT SO NO DUSTING OCCURS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLV IS EXCEEDED, USE NIOSH APPROVED ORGANIC
    RESPIRATOR OR SUPPLIED AIR SYSTEM, AVOIDING SOURCES OF IGNITION.
Ventilation:SUFFICIENT TO KEEP VAPORS BELOW TLV.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH SKIN W/SOAP & WATER OR WATERLESS CLEANER.
    DO NOT USE SOLVENTS.
Supplemental Safety and Health
EXPLAN OF CARCIN:TO BE CARCINOGENIC. CFR VOL 29, PG 1910.1001,
    1987:OSHA CANCER HAZARD. HUMAN:LUNGS, LIVER, KIDNEY.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>310F,>154C
Vapor Pres:SEE ING 1
Vapor Density:HVR/AIR
Spec Gravity:1.2 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT & SOURCES OF IGNITION.
Hazardous Decomposition Products:SMOKE & OXIDES OF CARBON.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS . DISPOSE OF AS SOLID WASTE PER LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
FLAME SHIELD LATEX INTUMESCENT COATING, 076100 13463-67-7
57-55-6
61788-76-9
108-78-1
56-23-5
7732-18-5
FLAME SHIELD CLEAR INTUMESCENT COATING, 091039 8052-41-3
64742-95-6
61788-76-9
56-23-5
SNAP WRAP INSULATION 25104-55-6
24937-78-8
METAL BUILDING INSULATION 202 25104-55-6
24937-78-8
DURA 141 A/C FLUSH SOLVENT, 409517 1717-00-6
DURA 141 A/C FLUSH SOLVENT, 409518 1717-00-6
AMMONIUM CITRATE DIBASIC, 2045 ACS GRANULAR 3012-65-5
AMMONIUM CITRATE DIBASIC, 2046 PURIFIED GRANULAR 3012-65-5
POTASSIUM CHROMATE, P220 100 7789-00-6
POTASSIUM CHROMATE, P220 3 7789-00-6
POTASSIUM CHROMATE, P220 500 7789-00-6
POTASSIUM CHROMATE, P220-100 7789-00-6
POTASSIUM CHROMATE, P220-3 7789-00-6
POTASSIUM CHROMATE, S71231 7789-00-6
POTASSIUM CHROMATE, S71231-1 7789-00-6
POTASSIUM CHROMATE, S71231-2 7789-00-6
POTASSIUM CHROMATE, S71231-3 7789-00-6
POTASSIUM CHROMATE, S77393 7789-00-6
HYDROFLUORIC ACID, A146 10LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A146 1LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A146-10LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A146-1LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A147 10LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A147-10LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A147-1LB 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A463 500 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A463-1 7664-39-3
7732-18-5
HYDROFLUORIC ACID, A463-500 7664-39-3
7732-18-5
QUALITY CONTROL STANDARD 7A, QC-7A 7697-37-2
7732-18-5
7440-09-7
7440-21-3
7429-90-5
7440-39-3
7440-42-8
7440-23-5
7440-22-4
FAST DRY SELF VULCANIZING CEMENT (SEE SUPPLEMENTAL FOR PC) 142-82-5
67-64-1
35884-05-0
ENERGIZER;HEARWELL;OVERTIME 1313-13-9
7439-97-6
1310-58-3
20667-12-3
1310-73-2
7440-66-6
5964, ACRYL-BLUE GLAZING PUTTY 60-9800-0597-3 (SUPDAT) 14807-96-6
13463-67-7
108-88-3
123-86-4
1330-20-7
9010-88-2
9004-36-8
85-68-7
67-63-0
SULFURIC ACID, A298 212 7664-93-9
CALCIUM HYPOCHLORITE GRANULAR 7778-54-3
GLYCOL ETHER EB;ETHYLENE GLYCOL MONOBUTYL ETHER;BUTYL GLYCOL 111-76-2
107-21-1
71-36-3
C-1 EPOXY ADHESIVE, RESIN, PART A 25036-25-3
106-92-3
25068-38-6
SPARKLEEN I, 04-320 497-19-8
PETRAULIC 46 8012-95-1
PLASTIC ROOF CEMENT, 204 64742-88-7
12001-29-5
HYSOL M-9-N (XX0018), PART 1 112-15-2
8005-70-0
25068-38-6
106-89-8
N-AMYL ACETATE, A-718 628-63-7
ZYGLO PENETRANT ZL-1D 8042-47-5
HEXANE IN AIR 110-54-3
E-59 REMOVER 64742-88-7
ARMOR 22 FLOOR & SEAL, 10-100 111-77-3
34590-94-8
84-74-2
VACTAN (5 LITER BOTTLE) 111-76-2
1401-55-4
25586-24-7
DINITROL AV30 64475-85-0
111-76-2
823 0203 SOLEX PLATE FINISHER, 1 GALLON READY TO USE 7732-18-5
9004-53-9
7558-80-7
9003-39-8
878 3201 REVERSAL BATH REPLENISHER, PROCESS E-6 AND E-6AR 137-40-6
6419-19-8
79-09-4
7772-99-8
7732-18-5
878 3201 REVERSAL BATH REPLENISHER, PROCESS E-6 & E-6AR, WS 7732-18-5
137-40-6
6419-19-8
79-09-4
7772-99-8
2235-43-0

Free MSDS Search ( Providing 250,000+ Material Properties )