===================== Product Identification =====================
MSDS NAME:ENPLATE REDUCER, 3331
NIIN:00N086593
MSDS Number: CHJJN
=== Responsible Party ===
Company:ENTHONE-OMI INC
Box:1900
City:WEST HAVEN
State:CT
ZIP:06508
Country:US
Info Phone Num:203-934-8611
Emergency Phone Num:800-424-9300 (CHEMTREC)
Preparer's Name:BA WHALEN
CAGE:GO075
=== Contractor Identification ===
Company:ENTHONE-OMI INC
Box:1900
City:NEW HAVEN
State:CT
ZIP:06508
Country:US
Phone:203-934-8611/203-799-8179
CAGE:GO075
Company:ENTHONE-OMI INC.
Address:Box:1900
City:NEW HAVEN
State:CT
ZIP:06508
Country:US
Phone:203-934-8611/ FAX 203-799-8179
CAGE:02258
============= Composition/Information on Ingredients =============
Name:FORMALDEHYDE (SARA 302/313) (CERCLA)
CAS:50-00-0
RTECS #:LP8925000
Fraction by Wt: <40%
OSHA PEL:SEE 1910.1048
ACGIH TLV:C 0.3 PPM, A2
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:METHANOL; (METHYL ALCOHOL) (SARA 313) (CERCLA)
CAS:67-56-1
RTECS #:PC1400000
Fraction by Wt: <15%
OSHA PEL:200 PPM, S
ACGIH TLV:200 PPM/250 STEL, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: >45%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUP DAT: WASHING EYES W/IN SEVERAL SECONDS OF EXPOSURE IS
ESSENTIAL TO MINIMIZE DAMAGE. SEEK IMMED MEDICAL ATTENTION.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: INHAL: HIGHLY IRRITATING TO
NASAL PASSAGES. CAN CAUSE INFLAMM OF LINING OF NOSE, THROAT, &
LUNGS. OVEREXP MAY CAUSE HDCH, NAUS, DIZZ, & BLURRING OF VISION.
INGEST: CAN CAUSE SEV IRRIT & INFLAMM OF MOUTH, THROAT, & STOM, AS
WELL AS BLINDNESS, STUPOR, NAUS, VOMIT, & POSS DEATH. SKIN: CAN
CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMALDEHYDE: IARC MONO, SUPP, VOL 62,
PG 217, 1995: GROUP 2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994: ANTIC
TO (SUP DAT)
Effects of Overexposure:HLTH HAZ: SEV IRRIT & SENSIT. EYES: VAP CAUSES
IRRIT & TEARING. CONT W/LIQ CAN CAUSE SEV BURNS & POSS BLINDNESS.
CHRONIC: MAY CAUSE SENSIT & REDUCED VISION. LIFETIME INHAL STUDY OF
RATS EXPOSED TO FOR MALDEHYDE GAS INDICATED DEVELOPMENT OF NASAL
CANCERS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE FROM CONTAM AREA. IF BRTHG HAS STOPPED,
RESUSCITATE & ADMIN OXYGEN IF AVAIL. SEEK IMMED MED ATTN. INGEST:
NEVER GIVE ANYTHING BY MOUTH TO AN UNCON PERSON. OBTAIN IMMED MED
ATTN. IF VOMIT OCCURS SPONT, KEEP AIRWAY CLEAR. IF SWALLOWED GIVE
LGE AMTS OF WATER & INDUCE VOMIT. SEEK IMMED MED ATTN. SKIN: IMMED
WASH W/PLENTY OF WATER FOR 15 MIN. REMOVE CONTAM CLTHG & FOOTWEAR.
(SUP DAT)
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:140F,60C
Lower Limits:7%
Upper Limits:73%
Extinguishing Media:WATER FOG OR SPRAY, CARBON DIOXIDE, DRY CHEMICAL,
ALCOHOL FOAM.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . KEEP CONTAINERS COOL TO PREVENT RUPTURE AND RELEASE OF
MATERIAL.
Unusual Fire/Explosion Hazard:VAPORS MAY TRAVEL TO SOURCES OF IGNITION
DISTANT FROM POINT OF HANDLING OR SPILLAGE.
================== Accidental Release Measures ==================
Spill Release Procedures:AVOID CONT W/SKIN, EYES, & CLTHG. WEAR PROT
EQUIP. DO NOT BREATHE MIST/VAPS. ELIM SOURCES OF IGNIT (HEAT, SPKS,
& OPEN FLAMES). PROPERLY VENT AREA. CONTAIN SPILL & SOAK UP IN
SUITABLE ABSORB. SHOVEL U P INTO PLASTIC-LINED STEEL CONTRS &
COVER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP AWAY
FROM ACIDS AND OXIDIZERS. LOOSEN COVER CAUTIOUSLY WHEN OPENING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH APPRVD RESP WHEN AIR CONC IS GREATER
THAN TLV/PEL. USE FULL FACE NIOSH APPRVD FORMALDEHYDE/ACID GAS
CARTRIDGE/CANISTER RESP W/IN USE LIMITATIONS OF THESE DEVICES. IN
ALL OTHER SITUATIONS, US E NIOSH APPRVD SCBA.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYEWASH AND DELUGE
SHOWER . CHEMICALLY RESISTANT COVERALLS, HAT, AND SHOES OF BOOTS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EXPLAN OF CARCIN: BE CARCIN. OSHA REGULATED: CFR 29 1910.1048. ANIMAL:
NASAL TUMORS. FIRST AID PROC: WASH CLTHG BEFORE REUSE. DISCARD
CONTAM LEATHER CLTHG, BELTS/FOOTWEAR. SEEK IMMED MED ATTN. EYES: I
MMED FLUSH W/WATER FOR AT LEAT 15 MIN HOLDING LIDS APART TO ENSURE
FLUSHING OF ENTIRE SURFACE. (ING 4)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:208F,98C
Vapor Pres:27
Vapor Density:1.03
Spec Gravity:1.085 (H*2O=1)
pH:3
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID WITH PUNGENT, IRRITATING ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALIES, ALKALI METALS, AMINES, ACIDS, OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, AND FLAME.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:FOR WASTE DISPOSAL OF SPILLED OR CONTAMINATED
PRODUCT FOLLOW MANUFACTURER WASTE DISPOSAL PROCEDURES. IF
NECESSARY, CONSULT MANUFACTURER FOR DISPOSAL ASSISTANCE. DISPOSE OF
IN ACCORDANCE WITH LOCAL, ST ATE, AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|