===================== Product Identification =====================
MSDS NAME:AMMONIUM SULFATE, AC-0646
NIIN:01-336-8095
MSDS Number: CHKFX
=== Responsible Party ===
Company:ANACHEMIA
Address:500 - 2ND AVE
City:VILLE ST PIERRE QUE, CANADA
Info Phone Num:518-297-4444
Emergency Phone Num:613-996-6666;800-424-9300(CHEMTREC)
CAGE:HO801
=== Contractor Identification ===
Company:ANACHEMIA
Address:3 LINCOLN BLVD
Box:City:ROUSES POINT
State:NY
ZIP:12979
Country:US
Phone:518-297-4444
CAGE:HO801
Company:ANACHEMIA CANADA
Address:255 NORMAN H8R 1A3
Box:City:VILLE ST. PIERRE (MONTREAL)
State:PQ
Country:CN
Phone:514-489-5711;518-297-4444
CAGE:36842
============= Composition/Information on Ingredients =============
Name:AMMONIUM SULFATE (SARA 313). LD50:(ORAL,RAT) 2840 MG/KG.
CAS:7783-20-2
RTECS #:BS4500000
Fraction by Wt: 99-100%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT:VOMIT. IF CONSCIOUS, WASH OUT MOUTH W/WATER. HAVE
CONSCIOUS PERS DRINK SEVERAL GLASSES OF WATER/MILK. SEEK(ING 3)
RTECS #:9999999ZZ
Name:ING 2:IMMEDIATE MEDICAL ATTENTION. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON.
RTECS #:9999999ZZ
Name:OTHER PREC:RAISING DUST. HANDLE & OPEN CNTNR W/CARE. DO NOT
GET IN EYES, ON SKIN/ON CLTHG. I/A/W GOOD STOR & (ING 5)
RTECS #:9999999ZZ
Name:ING 4:HNDLG PRACTICES, DO NOT ALLOW SMOKING & FOOD
CONSUMPTION WHILE HNDLG. AVOID ALL CONT W/PROD. AVOID PRLNG/ (ING
6)
RTECS #:9999999ZZ
Name:ING 5:REPEATED EXPOSURE.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HARMFUL BY INGESTION, INHALATION
OR SKIN ABSORPTION. EYE:CAUSES IRRITATION. SKIN:CAUSES IRRITATION.
REPEATED OR PROLONGED CONTACT MAY CAUSE DERMATITIS.
INHALATION:MATERIAL IS IRRITATING TO MUCOU S MEMBRANES AND UPPER
RESPIRATORY TRACT. INGESTION:CAUSES GASTROINTESTINAL (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:IRRITATION. ABDOMINAL PAIN. ANEMIA,
COLIC, SHIVER, ATAXIA, ULCERATION, HEPATOMEGALIA. CHRONIC:TO THE
BEST OF MFR'S KNOWLEDGE, THE CHEMICAL, PHYSICAL AND TOXICITY OF
THIS SUBSTANCE HAS NOT BEE N FULLY INVESTIGATED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes:IMMED FLUSH W/COPIOUS QTYS OF WATER FOR AT LST 15 MINS,
HOLDING LIDS APART TO ENSURE FLUSHING OF ENTIRE SURF. CALL MD.
SKIN:IMMED FLUSH W/PLENTY OF WATER & SOAP FOR AT LST 15 MINS WHILE
REMOVING CONTAM CLTHG & SHOES. CALL MD. WASH CONTAM CLTHG BEFORE
REUSING. INHAL:REMOVE PATIENT TO FRESH AIR. ADMIN APPRVD OXYG
SUPPLY IF BRTHG IS DFCLT. ADMIN ARTF RESP OR CPR IF BRTHG HAS
CEASED. CALL(SUPDAT)
===================== Fire Fighting Measures =====================
Extinguishing Media:USE FLOODING QUANTITIES OF WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL CONTAINING VESSELS W/FLOODING QUANTITIES OF WATER
UNTIL WELL AFTER FIRE IS OUT.
Unusual Fire/Explosion Hazard:CONT W/OXIDIZING AGENTS MAY CAUSE FIRE
&/OR EXPLO. EMITS TOX FUMES UNDER FIRE CNDTNS. DECOMPOSES AT 235C
W/EMISSIONS OF AMMONIA & SULFUR TRIOXIDE. FIRE (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR NIOSH APPROVED SCBA, RUBBER BOOTS & HEAVY
RUBBER GLOVES. SWEEP UP & PLACE IN CONTAINER FOR DISPOSAL. AVOID
RAISING DUST. VENTILATE AREA & WASH SPILL SITE AFTER MATL PICK UP
IS COMPLETE. DO NOT EM PTY INTO DRAINS. DO NOT TOUCH SPILLED
MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:FOR LAB USE ONLY. STORE IN COOL PLACE
AWAY FROM HEATED AREAS, SPKS & FLAME. STORE IN WELL VENTED AREA.
STORE AWAY FROM INCOMPAT MATLS. HARMFUL SOLID!
Other Precautions:IRRITANT! DO NOT ADD ANY OTHER MATL TO CNTNR. DO NOT
WASH DOWN DRAIN. DO NOT BREATHE DUST. KEEP AWAY FROM DIRECT
SUNLIGHT/STRONG INCANDESCENT LIGHT. KEEP CNTNR TIGHTLY CLSD & DRY.
MAY CATCH FIRE IN PR ESENCE OF OXIDIZING MATLS. AVOID (ING 4)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH APPROVED DUST MASK. MINIMIZE DUST
GENERATION AND EXPOSURE - USE NIOSH APPROVED DUST MASK OR
APPROPRIATE PROTECTION. IN CASE OF INSUFFICIENT VENTILATION, WEAR
SUITABLE NIOSH APPRVD RESP EQUIP .
Ventilation:LOC MECH EXHST VENT CAPABLE OF MIN DUST EMISSIONS AT POINT
OF USE. MANIPULATE IN WELL VENTED AREA/UNDER ADEQ FUME HOOD.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . IMPERVIOUS APRON, COVERALLS &/OR OTHER RESIST PROT CLTHG
(SUPDAT)
Work Hygienic Practices:WASH WELL AFTER USE. DO NOT WEAR CONTACT
LENSES.
Supplemental Safety and Health
MP:455F,235C (DECOMPOSES). EXPLO HAZ:DEGRADATION PRODS:OXIDES OF SULFUR
& NITROGEN, AMMONIA. MATLS TO AVOID:AMMONIUM NITRATE, POTASSIUM
NITRATE, POTASSIUM CHLORATE, POTASSIUM NITRITE, ALUMINUM, MAGNES
IUM, SODIUM HYPOCHLORITE. OTHER PROT EQUIP:SUFFICIENT TO PROT SKIN.
FIRST AID PROC:MD. INGEST:DO NOT INDUCE (ING 2)
================== Physical/Chemical Properties ==================
Melt/Freeze Pt:M.P/F.P Text:SUPP DATA
Decomp Temp:Decomp Text:455F,235C
Spec Gravity:1.77 (H*2O=1)
Solubility in Water:76.7G/100G H2O @ 25C
Appearance and Odor:WHITE CRYSTALS W/AMMONIA ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS, COPPER, COPPER ALLOYS, ALKALI, NITRATES, CHLORATES,
ZINC, NITRITES, ACIDS, ALKALI METALS, (SUPP DATA)
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, OPEN FLAMES &
ALL OTHER SOURCES OF IGNITION.
Hazardous Decomposition Products:OXIDES OF SULFUR & NITROGEN, AMMONIA.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . DISPOSE OF ACCORDING TO ALL APPLICABLE REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|