Search   
MSDS  
:
 P/N 812144 CALIBRATION CHECK GAS
CAS  
:
 10102-43-9
7727-37-9
NAME  
:
 nitric oxide (sara 302)
nitrogen
=====================  Product Identification  =====================

MSDS NAME:P/N 812144 CALIBRATION CHECK GAS
NIIN:01-441-1263
Status Code:A
MSDS Number: CHXDS
=== Responsible Party ===
Company:MINE SAFETY APPLIANCES - CORP HQTRS
Address:121 GAMMA DR
Box:426
City:PITTSBURGH
State:PA
ZIP:15230-0426
Country:US
Info Phone Num:412-967-3000
Emergency Phone Num:412-967-3000
CAGE:8F723
=== Contractor Identification ===
Company:MINE SAFETY APPLIANCES CO
Address:121 GAMMA DR
Box:426
City:PITTSBURGH
State:PA
ZIP:15230-0426
Country:US
Phone:724-733-9270
CAGE:8F723

=============  Composition/Information on Ingredients  =============

Name:NITRIC OXIDE (SARA 302)
CAS:10102-43-9
RTECS #:QX0525000
Fraction by Wt: 0.001%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:25 PPM
ACGIH TLV:25 PPM; 9596
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
Fraction by Wt: BALANCE
Other REC Limits:NONE RECOMMENDED
ACGIH TLV:ASPHYXIANT; 9596

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:NITRIC OXIDE IS A HIGHLY TOXIC GAS.
    THE TLV-TWA IS 25 PPM AND THE IDLH ASPHYXIANT. THE DILUTE NITROGEN
    IS A SIMPLE ASPHYXIANT.
Explanation of Carcinogenicity:NOT LISTED BY RTECS, OSHA, NTP OR IARC.
Effects of Overexposure:OVEREXPOSURE TO NITROGEN OXIDES CAN CAUSE
    COUGH, DIFFICULT BREATHING, FATIGUE, NAUSEA, CHEST CONGESTION,
    IRRITATION OF EYES AND RESPIRATORY TRACT, PULMONARY EDEMA AND
    DELAYED EDEMA, AND POSSIBLY METHE MOGLOBINEMIA.
Medical Cond Aggravated by Exposure:NO INFORMATION.

=======================  First Aid Measures  =======================

First Aid:REMOVE THE VICTIM TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION
    IF THE VICTIM IS NOT BREATHING. GIVE OXYGEN IF BREATHING IS
    DIFFICULT. GET MEDICAL ATTENTION IMMEDIATELY, EVEN IF THE VICTIM IS
    NOT COMPLAI NING OF DISCOMFORT. IMMEDIATE MEDICAL ATTENTION IS
    ADVISED IN ALL CASES WHERE APPRECIABLE INHALATION OF NO/NO2 IS
    BELIEVED TO HAVE OCCURRED, AS PULMONARY EDEMA MAY DEVELOP.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:THIS CALIBRATION GAS MIXTURE ISN'T FLAMMABLE.
Unusual Fire/Explosion Hazard:GAS UNDER PRESSURE, 500 PSIG AT 70F.
    DON'T EXCEED 120F.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA. AVOID BREATHING GAS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY WELL VENTILATED
    AREA. DON'T EXCEED 130F.
Other Precautions:AVOID BREATHING GAS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:DUE TO LIMITED AMOUNT OF GAS IN THE CYLINDER, &
    THE LOW RELEASE RATE EMPLOYED IN INSTRUMENT CALIBRATION,
    RESPIRATORY PROTECTION ISN'T INDICATED UNDER CONDITIONS OF INTENDED
    USE.
Ventilation:USE IN WELL VENTILATED AREA.ITABLE.
Work Hygienic Practices:AVOID BREATHING GAS.
Supplemental Safety and Health
FOLLOW THE CALIBRATION PROCEDURE DETAILED IN THE MSA INSTRUCTIONS
    MANUAL PROVIDED WITH THE INSTRUMENT UNDER CALIBRATION.

==================  Physical/Chemical Properties  ==================

HCC:G3
Vapor Density:<1
Appearance and Odor:COLORLESS GAS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:TEMP >130F.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DON'T PUNCTURE/INCINERATE CYLINDER. BEFORE
    DISCARDING CYLINDER, SLOWLY RELEASE CONTENTS TO A SAFE EXHAUST.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
CARBON DIOXIDE 124-38-9
KOVACS REAGENT 7647-01-0
100-10-7
71-41-0
ADHESIVE/SEALANT-GRAY,3145 RTV 1185-55-3
13463-67-7
68909-20-6
70131-67-8
CITRIC ACID ANHY USP,12412 77-92-9
ALCONOX
PST-315 SLICONE FLUID 63148-62-9
124 9259 RP X-OMAT DVLPR REPLENISHER,TO MAKE 10 GAL,PART A 7732-18-5
10117-38-1
123-31-9
111-46-6
497-19-8
124 9259 RP X-OMAT DVLPR REPLENISHER,WORKING SOLUTION 7732-18-5
10117-38-1
123-31-9
127-08-2
68310-08-7
3M BRAND ACRYL-RED PUTTY, ON:05966 14807-96-6
108-88-3
123-86-4
117-81-7
9004-70-0
67-63-0
1332-37-2
68038-41-5
SODIUM ELECTRODE RINSE SOLUTION #210258 1341-49-7
CHEMPLEX FM/AW #0 - #2 8042-47-5
NICKEL CADMIUM SEALED CELL BATTERY 1313-99-1
1310-58-3
1306-19-0
25587-80-8
CARBON DIOXIDE 124-38-9
CK1764P26 ELECTRON TUBE 68512-49-2
CADMIUM PLATED AIRCRAFT PART #151051 AND 2606091 7440-43-9
MULTISTICX 10 SG
SNYTHO-GLASS
INK CARTRIDGE 7732-18-5
64-02-8
POVIDONE IODINE SOLUTION
KILFROST 24 PINT CARTON 7732-18-5
107-21-1
NAPA MV 5W30 64742-65-0
68649-42-3
ASCARITE II 1310-73-2
1318-00-9
SEALED LEAD-ACID BATTERY 7664-93-9
7439-92-1
7446-14-2
TI 1173 GLASS P/N 794247-0001 7440-56-4
7440-36-0
7782-49-2
ROYCO 602 68649-11-6
120,PR-1592 1314-13-2
63148-62-9
NITROGEN, PART A 7727-37-9
HYDROGEN SULFIDE, PART B 7783-06-4
MINIPAX (4A MOLECULAR SIEVE) 14808-57-0
1313-59-3
1344-28-1
1309-48-4
BS1 BLUE SEAL LEAK STOPPER 557-04-0
10043-35-3
SC-1000
MA-110 RTU (SS22110) TURBINE ENGINE CLEANER
ELECTRON AEROSOL 64742-47-8
68647-72-3
124-38-9
ML 4800 PACKING
PROPRIETARY CHEMICAL C
ECOLINK 2005, CFC-FREE CONTACT CLEANER 1717-00-6
124-38-9
ROSIN CORE WIRE SOLDER 7440-31-5
7439-92-1
8050-09-7
CONTACT & TUNER CLNR,A 02202/CLEANING COMPOUND,SOLVENT 1717-00-6
67-63-0
124-38-9
ABC DRY CHEMICAL EXTINGUISHER,MARINER 110 E,466148 7722-76-1
7783-20-2
12001-26-2
8031-18-3
112945-52-5
68037-59-2
PENAIR HD-4 7732-18-5
9016-45-9
34590-94-8
68603-42-9
29911-27-1
NORPAR 13 64771-72-8
NITROGEN 7727-37-9
ARMAKLEEN M-AERO NS 102-71-6
PLUS-5,HIGH PERFORMANCE HANDWIPE DISSOLVENT 138-86-3
57018-52-7
34590-94-8
872-50-4
EP-A TONER CARTRIDGE 1317-61-9
ROYCO 560 68424-31-7
68424-33-9
68259-36-9
101-67-7
1330-78-5
P/N 812144 CALIBRATION CHECK GAS 10102-43-9
7727-37-9
ANTI-FREEZE COOLANT 107-21-1
7732-18-5
FREON 12 75-71-8
EAL ARTIC 68

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net