Search   
MSDS  
:
 NICKEL CADMIUM SEALED CELL BATTERY
CAS  
:
 1313-99-1
1310-58-3
1306-19-0
25587-80-8
NAME  
:
 nickel oxide
potassium hydroxide (cercla) (electrolyte solution)
cadmium oxide (sara 302/313) (cercla)
nylon 11
=====================  Product Identification  =====================

MSDS NAME:NICKEL CADMIUM SEALED CELL BATTERY
NIIN:01-211-9906
Status Code:A
MSDS Number: CHXBX
=== Responsible Party ===
Company:SAFT AMERICA INC, POWER SOURCES DIV
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31603
Country:US
Info Phone Num:912-247-2331
Emergency Phone Num:912-247-2331
CAGE:09052
=== Contractor Identification ===
Company:SAFT AMERICA INC.
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31602
Country:US
Phone:912-247-2331
CAGE:09052

=============  Composition/Information on Ingredients  =============

Name:NICKEL OXIDE
CAS:1313-99-1
RTECS #:QR8400000
Fraction by Wt: 10%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3 AS NI
ACGIH TLV:1 MG/M3 AS NI

Name:POTASSIUM HYDROXIDE (CERCLA) (ELECTROLYTE SOLUTION)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 19%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:CADMIUM OXIDE (SARA 302/313) (CERCLA)
CAS:1306-19-0
RTECS #:EV1925000
Fraction by Wt: 13%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG (CD)/M3 DUST
ACGIH TLV:0.01 MG(CD)/M3; 9596

Name:NYLON 11
CAS:25587-80-8
Fraction by Wt: 15%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:EXPOSURE TO HAZARDOUS COMPONENTS WILL
    HAPPEN ONLY IF BATTERY CASE IS BROKEN. IF CASE IS
    BROKEN:ELECTROLYTE IS CORROSIVE TO BODY TISSUES, CAUSING SEVERE
    BURNS. METALS MAY CAUSE IRRITATION. METAL FUMES  INHALED OR METALS
    INGESTED ARE TOXIC.
Explanation of Carcinogenicity:NIOSH RECOMMENDS THAT NICKEL & CADMIUM
    BE TREATED AS OCCUPATIONAL CARCINOGENS.
Effects of Overexposure:SEVERE IRRITATION, BURNS TO BODY TISSUES
    CONTACTED. EYE:SEVERE IRRITATION, BURNS. SKIN:BURNS, CHRONIC
    ECZEMA, NICKEL ITCH. INALATION (FUMES):RESPIRATORY IRRITATION,
    COUGH, HEADACHE, VOMITING, CHEST PA IN, CHILLS. INGESTION:BURNS,
    NAUSEA, G/I DISORDERS.
Medical Cond Aggravated by Exposure:MFR GAVE NO INFORMATION ON MSDS.

=======================  First Aid Measures  =======================

First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
    EYE:FLUSH W/WATER FOR 15 MIN. SKIN:WASH W/SOAP & WATER. REMOVE
    CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. INHALED:REMOVE FROM
    EXPOSURE. A ID OR RESTORE BREATHING AS NEEDED. INGESTED:DO NOT
    INDUCE VOMITING. GIVE 1-2 GLASSES OF MILK OR WATER TO DRINK. GET
    IMMEDIATE MEDICAL ATTENTION. NOTHING BY MOUTH IF UNCONSCIOUS.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:CARBON DIOXIDE, SAND
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS TO
    AVOID BREATHING TOXIC FUMES. WEAR PROTECTIVE CLOTHING TO PREVENT
    CONTACT W/ ELECTROLYTE SOLUTION.
Unusual Fire/Explosion Hazard:ELECTROLYTE IS CORROSIVE TO BODY TISSUES.
    REACTS W/ORGANIC COMPOUNDS & METALS. RELEASES EXPLOSIVE HYDROGEN
    GAS. RELEASES TOXIC CADMIUM FUMES IN FIRE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELECTROLYTE SPILL: FLUSH W/ WATER & NEUTRALIZE
    W/DILUTE ACID.
Neutralizing Agent:DILUTE ACID

======================	Handling and Storage  ======================

Handling and Storage Precautions:THESE CELLS & BATTERIES CONSTRUCTED
    FROM THEM MAY BE HIGHLY CHARGED& CAPEABLE OF HIGH ENERGY DISCHARGE.
    TAKE CARE TO HANDLE CELLS PROPERLY.
Other Precautions:AVOID SHORTING OR MISUSE THAT WILL RESULT IN RAPID
    UNCONTROLLED ELECTRICAL, CHEMICAL OR HEAT ENERGY RELEASE. DO NOT
    SHORT CIRCUIT - MAY CAUSE BURNS. DO NOT BREAK OPEN CELL. DO NOT
    ALLOW EXPOSED AN FLA ME OR SPARK TO COME NEAR THE CELLS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR IF CELL IS
    BROKEN OPEN DURING FIRE TO MAINTAIN EXPOSURE LEVELS BELOW TWA FOR
    CADMIUM & NICKEL COMPONENTS.
Ventilation:USE LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION.
    MAINTAIN OSHA PEL.
Protective Gloves:SYNTHETIC RUBBER FOR ELECTROLYTE EXPOS.
Eye Protection:SPLASH GOGGLES IF CELL ACTIVATES
Other Protective Equipment:RUBBER APRON OR EQUIPMENT IF EXPOSURE TO
    ELECTROLYTE SOLUTION IS LIKELY.
Work Hygienic Practices:KEEP FOOD AND TOBACCO AWAY FROM WORK AREA.
Supplemental Safety and Health
NONE

==================  Physical/Chemical Properties  ==================

HCC:C2
NRC/State Lic Num:NONE
Spec Gravity:1.250-1.30
Evaporation Rate & Reference:NOT DETERMINED
Solubility in Water:SEE APPEARANCE

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALUMINUM, ZINC, TIN, ACTIVE METALS. ACID, AROMATIC HYDROCARBONS,
    NITROCARBONS, HALOCARBONS.
Stability Condition to Avoid:MFR GAVE NO INFORMATION ON MSDS.
Hazardous Decomposition Products:NICKEL OXIDE, CADMIUM, CADMIUM OXIDE,
    POTASSIUM HYDROXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:STORAGE BATTERY IS HAZARDOUS WASTE UNDER RCRA.
    IT MAY BE RETURNED TO SAFT FOR RECYCLING. BATTERY IS TCLP TOXIC.
    BATTERY & ELECTROLYTE SOLUTION IS CORROSIVE. IF NOT RECYCLED, MUST
    BE DISPOSED I/A/W FED ERAL, STATE & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
CARBON DIOXIDE 124-38-9
KOVACS REAGENT 7647-01-0
100-10-7
71-41-0
ADHESIVE/SEALANT-GRAY,3145 RTV 1185-55-3
13463-67-7
68909-20-6
70131-67-8
CITRIC ACID ANHY USP,12412 77-92-9
ALCONOX
PST-315 SLICONE FLUID 63148-62-9
124 9259 RP X-OMAT DVLPR REPLENISHER,TO MAKE 10 GAL,PART A 7732-18-5
10117-38-1
123-31-9
111-46-6
497-19-8
124 9259 RP X-OMAT DVLPR REPLENISHER,WORKING SOLUTION 7732-18-5
10117-38-1
123-31-9
127-08-2
68310-08-7
3M BRAND ACRYL-RED PUTTY, ON:05966 14807-96-6
108-88-3
123-86-4
117-81-7
9004-70-0
67-63-0
1332-37-2
68038-41-5
SODIUM ELECTRODE RINSE SOLUTION #210258 1341-49-7
CHEMPLEX FM/AW #0 - #2 8042-47-5
NICKEL CADMIUM SEALED CELL BATTERY 1313-99-1
1310-58-3
1306-19-0
25587-80-8
CARBON DIOXIDE 124-38-9
CK1764P26 ELECTRON TUBE 68512-49-2
CADMIUM PLATED AIRCRAFT PART #151051 AND 2606091 7440-43-9
MULTISTICX 10 SG
SNYTHO-GLASS
INK CARTRIDGE 7732-18-5
64-02-8
POVIDONE IODINE SOLUTION
KILFROST 24 PINT CARTON 7732-18-5
107-21-1
NAPA MV 5W30 64742-65-0
68649-42-3
ASCARITE II 1310-73-2
1318-00-9
SEALED LEAD-ACID BATTERY 7664-93-9
7439-92-1
7446-14-2
TI 1173 GLASS P/N 794247-0001 7440-56-4
7440-36-0
7782-49-2
ROYCO 602 68649-11-6
120,PR-1592 1314-13-2
63148-62-9
NITROGEN, PART A 7727-37-9
HYDROGEN SULFIDE, PART B 7783-06-4
MINIPAX (4A MOLECULAR SIEVE) 14808-57-0
1313-59-3
1344-28-1
1309-48-4
BS1 BLUE SEAL LEAK STOPPER 557-04-0
10043-35-3
SC-1000
MA-110 RTU (SS22110) TURBINE ENGINE CLEANER
ELECTRON AEROSOL 64742-47-8
68647-72-3
124-38-9
ML 4800 PACKING
PROPRIETARY CHEMICAL C
ECOLINK 2005, CFC-FREE CONTACT CLEANER 1717-00-6
124-38-9
ROSIN CORE WIRE SOLDER 7440-31-5
7439-92-1
8050-09-7
CONTACT & TUNER CLNR,A 02202/CLEANING COMPOUND,SOLVENT 1717-00-6
67-63-0
124-38-9
ABC DRY CHEMICAL EXTINGUISHER,MARINER 110 E,466148 7722-76-1
7783-20-2
12001-26-2
8031-18-3
112945-52-5
68037-59-2
PENAIR HD-4 7732-18-5
9016-45-9
34590-94-8
68603-42-9
29911-27-1
NORPAR 13 64771-72-8
NITROGEN 7727-37-9
ARMAKLEEN M-AERO NS 102-71-6
PLUS-5,HIGH PERFORMANCE HANDWIPE DISSOLVENT 138-86-3
57018-52-7
34590-94-8
872-50-4
EP-A TONER CARTRIDGE 1317-61-9
ROYCO 560 68424-31-7
68424-33-9
68259-36-9
101-67-7
1330-78-5
P/N 812144 CALIBRATION CHECK GAS 10102-43-9
7727-37-9
ANTI-FREEZE COOLANT 107-21-1
7732-18-5
FREON 12 75-71-8
EAL ARTIC 68

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net