===================== Product Identification =====================
MSDS NAME:SODIUM ELECTRODE RINSE SOLUTION #210258
NIIN:01-209-0690
Status Code:A
MSDS Number: CHXBV
=== Responsible Party ===
Company:ORION RESEARCH INC.
Address:500 CUMMINGS CENTER
City:BEVERLY
State:MA
ZIP:01915-6199
Country:US
Emergency Phone Num:978-922-4400
CAGE:014G6
=== Contractor Identification ===
Company:ORION RESEARCH, INC.
Address:500 CUMMINGS CENTER
Box:City:BEVERLY
State:MA
ZIP:01915-6199
Country:US
Phone:978-232-6000
CAGE:014G6
============= Composition/Information on Ingredients =============
Name:AMMONIUM BIFLUORIDE (CERCLA)
CAS:1341-49-7
RTECS #:BQ9200000
Fraction by Wt: < 1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:2.5 MG (F)/M3
ACGIH TLV:2.5 MG (F)/M3; 9596
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:DEIONIZED WATER
Fraction by Wt: > 99%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY IRRITATE EYES, SKIN AND MUCOUS
MEMBRANES. MAY IRRITATE OR BURN THE SKIN AND UNDERLYING TISSUE.
INTERNAL IN LARGE DOSES CAN CAUSE FLUORIDE POISONING, VOMITING,
DIARRHEA, NAUSEA. CAN CAUSE SEVERE BO NE DAMAGE.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:SKIN IRRITATION, WEIGHT LOSS, RASHES.
Medical Cond Aggravated by Exposure:ASTHMA, ANOREXIA, DENTAL DEFECTS IN
CHRONIC EXPOSURE.
======================= First Aid Measures =======================
First Aid:WASH OFF CONTACT AREA WITH LARGE AMOUNTS OF WATER. CONTACT
PHYSICIAN FOR ALL TYPES OF EXPOSURE.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:WATER, CARBON DIOXIDE, ALCOHOL FOAM
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR SELF CONTAINED
BREATHING APPARATUS AND FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:HF FUMES MAY BE GIVEN OFF DURING A FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR PROTECTIVE CLOTHING. NEUTRALIZE SPILL
WITH SODIUM BICARBONATE. SET ASIDE IN PLASTIC CONTAINER FOR WASTE
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER SEALED. STORE AWAY FROM
ACIDS AND ALKALIES.
Other Precautions:AMMONIUM HYDROGEN FLUORIDE IS LISTED IN TABLE 302.4
OF 40CFR PART 302.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS
Ventilation:EXHAUST VENTILATION SUFFICIENT TO KEEP AIRBORNE
CONCENTRATIONS BELOW RESPECTIVE TLV'S.
Protective Gloves:RUBBER
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:LAB COAT. AN EMERGENCY EYEWASH AND SHOWER
SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Decomp Temp:Decomp Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:1
pH:3.2
Viscosity:NOT GIVEN
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:MISCIBLE
Appearance and Odor:COLORLESS LIQUID, NO ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS, ALKALIES
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HYDROFLUORIC ACIDS FUMES
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT FEDERAL, STATE AND LOCAL LAWS FOR WASTE
DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|