Search   
MSDS  
:
 NICKEL CADMIUM AIRCRAFT BATTERY
CAS  
:
 1313-99-1
1310-58-3
1306-19-0
7440-50-8
NAME  
:
 nickel oxide solid
electrolyte solution (30% potassium hydroxide)
cadmium oxide solid
copper
nylon ii
=====================  Product Identification  =====================

MSDS NAME:NICKEL CADMIUM AIRCRAFT BATTERY
NIIN:01-186-0402
MSDS Number: CJFZV
=== Responsible Party ===
Company:SAFT AMERICA INC, POWER SOURCES DIV
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31603
Country:US
Info Phone Num:912-247-2331
Emergency Phone Num:912-247-2331
Chemtrec Ind/Phone:(800)424-9300
CAGE:09052
=== Contractor Identification ===
Company:SAFT AMERICA INC.
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31602
Country:US
Phone:912-247-2331
Contract Num:SP0430-96-D0552
CAGE:09052

=============  Composition/Information on Ingredients  =============

Name:NICKEL OXIDE SOLID
CAS:1313-99-1
RTECS #:QR8400000
= Wt:18.
OSHA PEL:1 MG/M3

Name:ELECTROLYTE SOLUTION (30% POTASSIUM HYDROXIDE)
CAS:1310-58-3
Code:F
RTECS #:TT2100000
= Wt:19.
Other REC Limits:2 MG/M3 CEILING AIR
ACGIH STEL:C2 MG/M3

Name:CADMIUM OXIDE SOLID
CAS:1306-19-0
RTECS #:EV1925000
= Wt:13.
OSHA PEL:5 MCG/M3 DUST
ACGIH TLV:0.05 MG/M3 CEILING

Name:COPPER
CAS:7440-50-8
RTECS #:GL5325000
= Wt:9.
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Name:NYLON II
= Wt:15.

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES
Health Hazards Acute and Chronic:CONTACT WITH ELECTROLYTE CAUSES
    IMMEDIATE SEVERE DAMAGE; MAY RESULT IN BLINDNESS. CONTACT WITH
    ELECTROLYTE MAY CAUSE SERIOUS BURNS TO SKIN. CONTACT WITH NICKEL
    MAY CAUSE SKIN SENSITIZATION, ECZEMA OR  NICKEL ITCH. INGESTION OF
    ELECTROLYTE CAUSES THROAT TISSUE DAMAGE AND GI TRACT DAMAGE.
    INGESTION OF NICKEL CAUSES NAUSEA & INTESTINAL DISORDERS.
    INHALED-INHALATION OF KOH MIST CAUSES IRRITATION OF NAS AL MUCOUS
    AND RESPIRATORY TRACT. INHALATION OF CADMIUM OXIDE MAY CAUSE
    RESPIRATORY IRRITATION, CHILLS. CHRONIC OVEREXPOSURE TO CADMIUM
    COMPOUNDS MAY RESULT IN PULMONARY EDEMA, KIDNEY DAMAGE.
Explanation of Carcinogenicity:NIOSH RECOMMENDS THAT NICKEL & CADMIUM
    BE TREATED AS OCCUPATIONAL CARCINOGENS.
Effects of Overexposure:EYES-BLINDESS, SEVERE DAMAGE, IRRITATION.
    SKIN-SERIOUS BURNS, ITCH. INGESTED-TISSUE DAMAGE TO THROAT & GI
    TRACT, NAUSEA, INTESTINAL DISORDERS. INHALED-IRRITATION OF NASAL
    MUCOUS MEMBRANES & RESPIRATOR Y TRACT TISSUES; CADMIUM OXIDE-DRY
    THROAT, COUGH, HEADACHE, VOMITING, CHEST PAIN, CHILLS, BREATHING
    DIFFICULTY, PROSTRATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:ELECTROLYTE:EYES-FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
    MINUTES. GET IMMEDIATE MEDICAL ATTENTION. SKIN-REMOVE CONTAMINATED
    CLOTHES & FLLUSH AFFECTED AREAS WITH PLENTY OF WATER FOR AT LEAST
    15 MINU TES. INGESTED-DO NOT INDUCE VOMITING! DILUTE BY GIVING
    WATER. IF AVAILABLE GIVE SEVERAL GLASSES OF MILK. GET IMMEDIATE
    MEDICAL ATTENTION. DO NOT GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
    PERSON. INHALE D-REMOVE TO FRESH AIR. GIVE OXYGEN OR ARTIFICIAL
    RESPIRATION IF NEEDED. GET IMMEDIATE MEDICAL ATTENTION.
    NICKEL:SKIN-WASH WITH COLD WATER & SOAP.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS TO
    AVOID BREATHING TOXIC FUMES. WEAR PROTECTIVE CLOTHING & EQUIPMENT
    TO PREVENT POTENTIAL BODY CONTACT WITH ELECTROLYTE SOLUTION OR
    MIXTURE OF WATER & SOLUTION.  DISCONNECT OR CUT CABLES TO & FROM
    BATTERY.
Unusual Fire/Explosion Hazard:ELECTOLYTE IS CORROSIVE. REACTS VIOLENTLY
    WITH MANY ORGANIC CHEMICALS, ESPECIALLY NITROCARBONS &
    CHLOROCARBONS. ELECTROLYTE SOLUTIONS REACTS WITH ZINC, ALUMINUM,
    TIN & OTHER ACTIVE MATERIALS RELEASING  FLAMMABLE HYDROGEN GAS.
    CADMIUM FUMES MAY BE RELEASED UNDER HIGH TEMPERATURE CONDITIONS; DO
    NOT BREATH SMOKE & FUMES!

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELECTROLYTE/SMALL: FLUSH WITH WATER &
    NEUTRALIZE WITH DILUTE CITRIC ACID. LARGE 9MORE THAN 5 GALLONS):
    CONTAIN MATERIAL IN SUITABLE CONTAINERS OR HOLDING AREA. DO NOT
    ALLOW MATERIAL INTO SEWERS, STREA MS OR STORM CONDUITS. RECOVER
    MATERIAL WITH VACUUM TRUCK & DISPOSE OF PROPERLY. REPORTABLE
    QUANTITY (ELECTROLYTE): 1000 LBS, 40 CFR 117.13.
Neutralizing Agent:DILUTE CITRIC ACID.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT TRANSPORT BATTERIES WITHOUT
    BATTERIES WITHOUT VENT CAP IN PLACE. WHEN REMOVING BATTERY FROM
    SERVICE VISUALLY INSPECT FOR LEAKAGE PRIOR TO HANDLING.IF LEAKAGE
    AHS OCCURED, FOLLOW SPILL PROCEDURE S. DO NOT ALLOW AN EXPOSED
    FLAME OR SPARK TO COME NEAR CELLS.
Other Precautions:THESE CELLS & THE BATTERIES CONSTRUCTED FROM THEM MAY
    BE HIGHLY CHARGED AND ARE CAPABLE OF HIGH ENERGY DISCHARGE. CARE
    SHOULD BE TAKEN TO HANDLE CELLS PROPERLY TO AVOID SHORTING OR
    MISUSE THAT WILL RE SULT IN RESULT IN RAPID UNCONTROLLED
    ELECTRICAL, CHEMICAL OR HEAT ENERGY RELEASE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR DURING LEVEL
    CHANGING TO MAINTAIN EXPOSURE LEVELS BELOW THE TWA.
Ventilation:PERFORM LEVEL CHARGING PROCEDURES IN A WELL VENTILATED
    AREA. BATTERY OPERATING AREAS MUST BE WELL VENTILATED TO REMOVE
    NORMAL GASES GENERATED.
Protective Gloves:WATER-INSOLUBLE NON-PERMEABLE GLOVE-SYNTHETIC RUBBER.
    DO NOT USE WOOL OR LEATHR
Eye Protection:USE SPLASH GOGGLES OR FACE SHIELD WHENEVER HANDLING A
    BATTERY.
Other Protective Equipment:RUBBER BOOTS, RUBBER APRON OR RAIN WEAR OR
    EQUIVALENT IF EXPOSURE TO ELECTROLYTE SOLUTION IS
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
DLSC U/I IS INCORRECT (19 EA PER BOX). CORRECT DATA, AS RECEIVED BY DLA
    DEPOTS,  IS 19 CELLS PER BATTERY.

==================  Physical/Chemical Properties  ==================

HCC:B1
Spec Gravity:1.250-1.30 (ELECTROLYTE)
Evaporation Rate & Reference:NOT DETERMINED
Solubility in Water:COMPLETE (ELECTROLYTE)

=================  Stability and Reactivity Data  =================

ELECTROLYTE WILL REACT WITH ALUMINUM, ZINC, TIN & OTHER ACTIVE METALS,
    ACID, CHLORINATED & AROMATIC HYDROCARBONS, NITROCARBONS,
    HALOCARBONS. TRICHLOROETHYLENE WILL REACT (SEE OTHER)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NICKEL OXIDE, CADMIUM, CADMIUM OXIDE,
    AND POTASSIUM HYDROXIDE. NOTE THAT NORMAL REACTION INSIDE BATTERY
    LIBERATE FLAMMABLE HYDROGEN GAS. BATTERY MUST BE VENTED TO
    ATMOSPHERE.
Conditions to Avoid Polymerization:HAZARDOUS POLYMERIZATION WILL NOT
    OCCUR.

===================  Toxicological Information	===================

Toxicological Information:NONE SPECIFIED BY MANUFACTURER.

=====================  Ecological Information  =====================

Ecological:NONE SPECIFIED BY MANUFACTURER.

====================  Disposal Considerations  ====================

Waste Disposal Methods:THE STORGAE BATTERY IS A HAZARDOUS WASTE UNDER
    RCRA. IT MAY BE RETURNED TO SAFT FOR RECYCLING. BATTERY IS TCLP
    TOXIC. BATTERY & ELECTROLYTE ARE CORROSIVE. IF NOT RECYCLED, MUST
    BE DISPOSED OF IN ACCOR DANCE WITH ALL FEDERAL, STATE & LOCAL
    REGULATIONS.

===================  MSDS Transport Information  ===================

Transport Information:NONE SPECIFIED BY MANUFACTURER.

=====================  Regulatory Information  =====================

SARA Title III Information:NONE SPECIFIED BY MANUFACTURER.
Federal Regulatory Information:BATTERY IS TCLP TOXIC. CERCLA REPORTABLE
    QUANTITY (ELECTROLYTE) (RQ): 1000 LBS, 40 CFR 117.13. THE STORAGE
    BATTERY IS A HAZARDOUS WASTE UNDER RCRA.
State Regulatory Information:NONE SPECIFIED BY MANUFACTURER.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
EXTERIOR TRIM ENAMEL #24664 GREEN (LEAD AND CHROMATE FREE) 25265-77-4
SEMI-GLOSS ENAMEL #26307 GREY 64742-88-7
BLACK TRAFFIC LINE PAINT, TYPE 1, #37038 1073(A-A-2886) 8032-32-4
64742-89-8
108-88-3
550 FLUID 33204-76-1
10448-09-6
63148-52-7
SODIUM HYDROXIDE, PURUM PELLETS, BW359500 13463-67-7
1330-20-7
100-41-4
SODIUM HYDROXIDE, PURUM PELLETS, BW1358350 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, NC9517818 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318 100 1310-73-2
V-740 VISILOX 1314-13-2
63148-62-9
SULFURIC ACID, 52-100% 7664-93-9
7732-18-5
V-740 VISILOX 1314-13-2
63148-62-9
S0266 SPERMIDINE FREE BASE MOLECULAR BIOLOGY REAGENT 124-20-9
4456 ULTANE SEVOFLURANE 28523-86-6
HT BASE OILS, 661-840 TO 661-846 72623-86-0
72623-87-1
72623-85-9
SODIUM HYDROXIDE, PURUM PELLETS, S318 50 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318-10 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318-5 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S3181 7173-51-5
8001-54-5
2605-78-9
139-33-3
7732-18-5
SODIUM HYDROXIDE, PURUM PELLETS, BW1358050 1310-73-2
SULFUR HEXAFLUORIDE 2551-62-4
SODIUM HYDROXIDE, PURUM PELLETS, BW13583500 1310-73-2
ANTIBLAZE 100, 99G 115-96-8
107-06-2
96/4 ROSIN CORE SOLDER 7440-31-5
7440-22-4
8050-09-7
7439-92-1
SODIUM HYDROXIDE, PURUM PELLETS, S318 1 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318 3 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318 500 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318-100 1310-73-2
SODIUM HYDROXIDE, PURUM PELLETS, S318-50 1310-73-2
QUININE SULFATE, DIHYDRATE 6119-70-6
SUSCEPTIBILITY TEST DISCS, 0423045
85001/KF DRI ALERT, IGE 1313-59-3
1305-78-8
12136-45-7
7631-86-9
1344-28-1
1332-58-7
60676-86-0
7732-18-5
SODIUM HYDROXIDE, PURUM PELLETS, S31810 1317-65-3
14808-60-7
25265-77-4
7732-18-5
SODIUM HYDROXIDE, PURUM PELLETS, BW13580500 1310-73-2
ZINC OXIDE 1314-13-2
BROWNELLS T.F.E. DRY LUBE & MOLD RELEASE, 083056016 74-98-6
75-28-5
142-82-5
67-63-0
NICKEL CADMIUM AIRCRAFT BATTERY 1313-99-1
1310-58-3
1306-19-0
7440-50-8
READY GEL, 586601 95-63-6
1330-20-7
GLYPTAL 1330-20-7
8030-30-6
108-88-3
8052-41-3
1309-37-1
14807-96-6
78-93-3
67-64-1
74-98-6
DOD-L-25681D 63148-52-7
1317-33-5
UNLEADED 87 86290-81-5
1330-20-7
108-88-3
71-43-2
109-66-0
95-63-6
110-54-3
106-97-8
100-41-4
142-82-5
1634-04-4
64-17-5
107-83-5
96-14-0
591-76-4
589-34-4
79-29-8
STADIS 450 CONDUCTIVITY IMPROVER 108-88-3
71-43-2
64742-94-5
67-63-0
91-20-3
25322-17-2
STENCIL PAINT, BLACK, COLOR NO. 37038 64742-89-8
8052-41-3
WHITE STENCIL PAINT COLOR #37875 108-88-3
8032-32-4
STENCIL PAINT, BLACK, COLOR NO. 37038 64742-89-8
8052-41-3
BLUE STENCIL PAINT 35109 64742-89-8
8052-41-3
GREEN STENCIL PAINT 34108 64742-89-8
108-88-3
8052-41-3
1344-37-2
7439-92-1
1333-82-0
ORANGE STENCIL PAINT 32246 64742-89-8
108-88-3
8052-41-3
1344-37-2
7439-92-1
1333-82-0
RED STENCIL PAINT 31136 64742-89-8
64742-95-6
RED STENCIL PAINT 31136 64742-89-8
64742-95-6
YELLOW STENCIL PAINT 33538 64742-89-8
108-88-3
8052-41-3
1344-37-2
7439-92-1
1333-82-0

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net