===================== Product Identification =====================
MSDS NAME:RED STENCIL PAINT 31136
NIIN:00-285-4931
Status Code:A
MSDS Number: CJGBW
=== Responsible Party ===
Company:FARWEST PAINT MFG CO
Address:4522 S 133 ST
Box:68726
City:TUKWILA
State:WA
ZIP:98168-3251
Country:US
Info Phone Num:206-244-8844
Emergency Phone Num:206-941-1619
CAGE:6F266
=== Contractor Identification ===
Company:FARWEST PAINT MANUFACTURING CO
Address:4522 SOUTH 133RD ST
Box:City:TUKWILA
State:WA
ZIP:98168
Country:US
Phone:206-244-8844
CAGE:6F266
============= Composition/Information on Ingredients =============
Name:ALIPHATIC HYDROCARBON
CAS:64742-89-8
Fraction by Wt: 13.46%
OSHA PEL:500 PPM
ACGIH TLV:300 PPM
Name:AROMATIC HYDROCARBONS
CAS:64742-95-6
Fraction by Wt: 17.64%
OSHA PEL:300 PPM
ACGIH TLV:300 PPM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: PROLONGED/REPEATED CONTACT MAY
CAUSE IRRITATION, SENSITIZATION, OR DEFATTING OF SKIN. INHAL:
EXCESSIVE EXPOSURE TO VAPORS/SPRAY MISTS CAN PRODUCE HEADACHE,
DIZZINESS, NAUSEA, & LOSS OF CONSCIOUS NESS. SOME REPORTS HAVE
ASSOCIATED REPEATED/PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS
W/ PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. EYES: IRRITANT.
Medical Cond Aggravated by Exposure:NONE WHEN USED IN ACCORDANCE WITH
HANDLING INSTRUCTIONS.
======================= First Aid Measures =======================
First Aid:SKIN: PROMPTLY WASH W/ SOAP & WATER. REMOVE AND WASH ANY
CONTAMINATED CLOTHING BEFORE REUSE. EYES: WASH W/ LARGE AMOUNTS OF
WATER FOR 15 MINUTES AND SEEK MED ATTN. INGEST: DO NOT INDUCE
VOMITING. KEEP WARM & QUIET, AND GET MED ATTN. ASPIRATION OF
MATERIAL INTO LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE
FATAL. SEEK MED ATTN. INHALATION: REMOVE TO FRESH AIR. IF
RESPIRATORY SYMPTOMS DEVELOP, SEEK MED ATTN AT ONCE.
===================== Fire Fighting Measures =====================
Flash Point:=10.C, 50.F
Lower Limits:1.0
Upper Limits:7.0
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG. ANY CLASS B
EXTINGUISHING AGENT. WATER MAY BE UNSUITABLE AS EXTINGUISHING
MEDIUM, BUT HELPFUL IN KEEPING ADJACENT CONTAINERS COOL.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS.
EVACUATE AREA OF UNPROTECTED PERSONEL. WEAR PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:VAPORS MAY FORM EXPLOSIVE MIXTURE IN AIR
& MAY BE IGNITED BY SPARKS, PILOT LIGHTS, ETC. CLOSED CONTAINERS
MAY RUPTURE WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE SOURCES OF IGNITION AND VENTILATE AREA.
ADSORB ON INERT MATERIAL SUCH AS SAWDUST, VERMICULITE, OR SAND,
AND PLACE MATERIAL IN CLOSED CONTAINER. LARGE SPILL: DIKE AREA TO
PREVENT FROM ENTERING SEWER OR WATERWAY. WEAR PROTECTIVE EQUIPMENT
DURING CLEAN UP.
Neutralizing Agent:NONE
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID PROLONGED/REPEATED INHALATION OF
HEATED VAPORS/SPRAY MISTS. KEEP AWAY FROM HEAT/OPEN FLAME. MATERIAL
MAY CAUSE SENSITIZATION. DO NOT GET IN EYES, ON SKIN OR CLOTHING.
DO NOT ALLOW CONTAM CLOTHIN G TO CONTACT SKIN. DO NOT WELD ON
FULL/EMPTY CONTAINERS.
Other Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN USE & PROPERLY
LABELED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:CANNISTER TYPE RESPIRATOR MUST BE WORN TO
PREVENT INHALATION OF VAPORS/SPRAY MISTS WHEN TLV/PEL EXCEEDED.
Ventilation:GENERAL VENTILATION DURING NORMAL USE. LOCAL VENTILATION
MAY BE REQUIRED DURING CERTAIN OPERATIONS TO KEEP EXPOSURE LEVEL
1
VOC Pounds/Gallon:411
Viscosity:75 - 90KU
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:RED MEDIUM VISCOUS LIQUID W / MILD, SWEET AROMATIC
ODOR
Percent Volatiles by Volume:<50
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS, ACIDS, BASES, AND EPOXY HARDENERS UNDER UNCONTROLLED
CONDITIONS.
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
OF IGNITION. IF PRODUCT CONTAINS ALUMINUM, MOISTURE IN CLOSED
CONTAINERS GENERATES HYDROGEN GAS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD CARBON
MONOXIDE AND TOXIC VAPORS.
==================== Disposal Considerations ====================
Waste Disposal Methods:MATERIAL AND CONTAINERS SHOULD BE TREATED AS HAZ
WASTE BASED ON IGNITIBILITY PER RCRA (40 CFR 261). DISPOSE
MATERIAL/CONTAINER IN COMPLIANCE W/ APPLICABLE LABELING, PACKAGING,
& RECORD KEEPING STANDAR DS. DISPOSE I/A/W ALL FEDERAL, STATE AND
LOCAL AGENCIES. GROUND HANDLING EQUIPMENT TO PREVENT SPARKS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|