===================== Product Identification =====================
MSDS NAME:143 9132,KODAK SUPRALIFE ALKALINE BATTERY (KN TYPE)
Status Code:A
MSDS Number: CKTRN
=== Responsible Party ===
Company:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-722-5151/(800) 242-2424
Emergency Phone Num:716 722-5151 PCC 202-625-3333
Preparer's Name:NOT PROVIDED
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
============= Composition/Information on Ingredients =============
Name:MANGANESE DIOXIDE
CAS:1313-13-9
RTECS #:OP0350000
Minumum % Wt:35.
Maxumum % Wt:40.
Other REC Limits:NOT PROVIDED
OSHA PEL:C5 MG/M3
ACGIH TLV:5 MG/M3
Name:ZINC POWDER
CAS:7440-66-6
RTECS #:ZG8600000
Minumum % Wt:10.
Maxumum % Wt:15.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:POTASSIUM HYDROXIDE
CAS:1310-58-3
RTECS #:TT2100000
Minumum % Wt:1.
Maxumum % Wt:5.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH STEL:C2 MG/M3
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Minumum % Wt:5.
Maxumum % Wt:10.
Other REC Limits:NOT PROVIDED
Name:GRAPHITE
CAS:7782-42-5
RTECS #:MD9659600
Minumum % Wt:1.
Maxumum % Wt:5.
Other REC Limits:NOT PROVIDED
OSHA PEL:SEE TABLE Z-3
ACGIH TLV:2 MG/M3
Name:STEEL CASING
Minumum % Wt:25.
Maxumum % Wt:30.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
Name:PAPER
Minumum % Wt:1.
Maxumum % Wt:5.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
Name:ALLOY BRASSY
Minumum % Wt:1.
Maxumum % Wt:5.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
Name:PLASTIC
Minumum % Wt:1.
Maxumum % Wt:5.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
Name:METALIZED PLASTIC LABEL
< Wt:1.
Other REC Limits:NOT PROVIDED
OSHA PEL:NOT PROVIDED
ACGIH TLV:NOT PROVIDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NOT PROVIDED
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF EXPOSURE: INHALATION:
HARMFUL IF INHALED. MAY CAUSE IRRITATION TO THE MUCOUS MEMBRANES
AND UPPER RESPIRATORY TRACT. EYES: CONTACT WITH ELECTROLYTE
(LIQUID) CAUSES BURNS. VAPORS OR FUMES MAY CAUSE IRRITATION.
CONTACT WITH METAL FRAGMENTS MAY CAUSE BURNS OR MECHANICAL INJURY.
SKIN: CONTACT WITH ELECTROLYTE (LIQUID) CAUSES BURNS. CONTACT WITH
METAL FRAGMENTS MAY CAUSE BURNS OR MECHANICAL I NJURY. HARMFUL IF
ABSORBED THROUGH SKIN. VAPORS OR FUMES MAY CAUSE IRRITATION.
INGESTION: ALL BATTERIES MAY BE HARMFUL IF SWALLOWED. MAY CAUSE
BURNS OF THE GASTROINTESTINAL TRACT.
Explanation of Carcinogenicity:(COMPONENTS PRESENT AT 0.1% OR MORE):
INTERNATIONAL AGENCY FOR RESEARCH ON CANCER (IARC): NONE. AMERICAN
CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH): NONE.
NATIONAL TOXICOLOGY PROGRAM (NT P): NONE. OCCUPATIONAL SAFETY AND
HEALTH ADMINISTRATION (OSHA): NONE.
Effects of Overexposure:INHALATION: MAY CAUSE IRRITATION TO THE MUCOUS
MEMBRANES AND UPPER RESPIRATORY TRACT. EYES: CONTACT WITH
ELECTROLYTE (LIQUID) CAUSES BURNS. VAPORS OR FUMES MAY CAUSE
IRRITATION. CONTACT WITH METAL FRA GMENTS MAY CAUSE BURNS OR
MECHANICAL INJURY. SKIN: CONTACT WITH ELECTROLYTE (LIQUID) CAUSES
BURNS. CONTACT WITH METAL FRAGMENTS MAY CAUSE BURNS OR MECHANICAL
INJURY. VAPORS OR FUMES MAY CAUSE IRRITATI ON. INGESTION: MAY CAUSE
BURNS OF THE GASTROINTESTINAL TRACT.
Medical Cond Aggravated by Exposure:NOT PROVIDED
======================= First Aid Measures =======================
First Aid:INHALATION: IF VAPORS/FUMES FROM LEAKING BATTERY ARE
IRRITATING, MOVE TO FRESH AIR. GET MEDICAL ATTENTION IF SYMPTOMS
PERSIST. EYES: IN CASE OF CONTACT WITH BATTERY CONTENTS,
IMMEDIATELY FLUSH WITH WA TER FOR AT LEAST 15 MINUTES. GET MEDICAL
ATTENTION IMMEDIATELY. SKIN: IN CASE OF CONTACT WITH BATTERY
CONTENTS, IMMEDIATELY FLUSH SKIN WITH WATER FOR AT LEAST 15 MINUTES
WHILE REMOVING CONTAMINATED CL OTHING AND SHOES. GET MEDICAL
ATTENTION IMMEDIATELY. INGESTION: CALL PHYSICIAN IMMEDIATELY. DO
NOT INDUCE VOMITING. BATTERIES MAY LODGE IN THROAT/DIGESTIVE TRACT.
IF BATTERY WAS LEAKING OR WAS CHEWED, RINSE MOUTH THOROUGHLY WITH
WATER.
===================== Fire Fighting Measures =====================
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS. WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:FIRE OR HIGH TEMPERATURES MAY CAUSE
BATTERY TO VENT AND/OR EXPLODE OR LEAK HAZARDOUS VAPORS. DAMAGED OR
OPENED BATTERIES CAN RESULT IN RAPID HEATING AND THE RELEASE OF
HAZARDOUS VAPORS.
================== Accidental Release Measures ==================
Spill Release Procedures:NOT APPLICABLE.
Neutralizing Agent:NOT PROVIDED
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, DRY PLACE. PROTECT FROM
DIRECT SUNLIGHT. STORAGE ABOVE 21C/70F MAY AFFECT PRODUCT QUALITY.
DO NOT STORE IN A MANNER THAT ALLOWS TERMINALS TO SHORT CIRCUIT.
EXTENDED SHORT CIRCUITING CRE ATES HIGH TEMPERATURES IN BATTERY
WHICH CAUSE LEAKAGE, EXPLOSION, FLAME, REDUCTION OF BATTERY LIFE.
Other Precautions:IF BATTERY HAS BEEN DAMAGED, DO NOT BREATHE FUMES/
VAPORS. DO NOT GET BATTERY CONTENTS IN EYES, ON SKIN, ON
CLOTHING.WASH THOROUGHLY AFTER HANDLING. DO NOT DISASSEMBLE. KEEP
AWAY FROM HEAT AND FLAME. DO NOT RECHARGE. AVOID USE OF OLD AND
NEW BATTERIES/BATTERIES OF VARYING SIZES AND TYPES IN THE SAME
BATTERY ASSEMBLY.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:SUPPLEMENTAL VENTILATION MAY BE NEEDED IN SPECIAL
CIRCUMSTANCES TO CONTROL FUMES/VAPORS TO AN ACCEPTABLE LEVEL.
Protective Gloves:WHEN HANDLING A DAMAGED BATTERY, WEAR IMPERVIOUS
GLOVES.
Eye Protection:WHEN HANDLING A DAMAGED BATTERY, WEAR SAFETY GLASSES
WITH SIDE SHIELDS/GOGGLES.
Other Protective Equipment:WASHING FACILITIES
Work Hygienic Practices:NOT PROVIDED
Supplemental Safety and Health
NOTE: THE ROUTINE HANDLING AND USE OF INTACT, NON-DAMAGED BATTERIES IS
NOT EXPECTED TO RESULT IN SITUATIONS THAT REQUIRE FIRST-AID
MEASURES. IF BATTERY IS DAMAGED DUE TO OPENING, CUTTING, CRUSHING,
OV ERHEATING, IMPROPER INSTALLATION, EXPOSURE TO FIRE OR HIGH
TEMPERATURES, OR RECHARGING, BATTERY CONTENTS MAY BE RELEASED
================== Physical/Chemical Properties ==================
HCC:N1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:NOT PROVIDED
Decomp Temp:Decomp Text:NOT PROVIDED
Vapor Pres:NEGLIGIBLE
Solubility in Water:INSOLUBLE
Appearance and Odor:PHYSICAL FORM: SOLID COLOR: NOT APPLICABLE ODOR:
ODORLESS
Corrosion Rate:NOT PROVIDED
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NOT PROVIDED
Hazardous Decomposition Products:OXIDES OF MANGANESE, OXIDES OF ZINC.
=================== Toxicological Information ===================
Toxicological Information:NOTE TO PHYSICIANS: BATTERY INGESTIONS SHOULD
NOT BE MANAGED IN THE SAME WAY AS OTHER SMALL METALLIC OBJECT
INGESTIONS, EG., COINS. THE POSITION AND INTEGRITY OF THE BATTERY
IN THE GASTROINTESTINAL TR ACT SHOULD BE ASSESSED AND MONITORED BY
X-RAY. LEAKING BATTERIES MAY CAUSE NECROSIS AND TISSUE DAMAGE. MOST
BATTERIES SMALLER THAN 22-25 MM IN DIAMETER WILL PASS SAFELY
THROUGH THE GUT. LARGER BATTERI ES OR BATTERIES THAT LODGE IN THE
GASTROINTESTINAL TRACT MAY HAVE TO BE REMOVED ENDOSCOPICALLY OR
SURGICALLY.
===================== Ecological Information =====================
Ecological:THIS MATERIAL HAS NOT BEEN TESTED FOR ENVIRONMENTAL EFFECTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT INCINERATE OR EXPOSE TO FIRE. DISCHARGE,
TREATMENT, OR DISPOSAL MAY BE SUBJECT TO NATIONAL, STATE, OR LOCAL
LAWS.
=================== MSDS Transport Information ===================
Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS
PRODUCT CALL THE KODAK WORLDWIDE TRANSPORTATION HAZMAT HOT LINE:
(716) 722-2400 BETWEEN 8 A.M. AND 5 P.M. (EASTERN STANDARD TIME),
MONDAY THROUGH FRIDAY.
===================== Regulatory Information =====================
Federal Regulatory Information:NOT PROVIDED
State Regulatory Information:MATERIAL(S) KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER: NONE. MATERIAL(S) KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE ADVERSE REPRODUCTIVE EFFECTS: NONE.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|