===================== Product Identification =====================
MSDS NAME:CHEMLUBE 80W
NIIN:01-152-1094
Status Code:A
MSDS Number: CLCGB
=== Responsible Party ===
Company:ULTRACHEM INC
Address:900 CENTERPOINT BLVD
City:NEW CASTLE
State:DE
ZIP:19720
Country:US
Info Phone Num:302-325-9880
Emergency Phone Num:302-325-9880
CAGE:56385
=== Contractor Identification ===
Company:ULTRACHEM INC
Address:900 CENTERPOINT BLVD
Box:City:NEW CASTLE
State:DE
ZIP:19720
Country:US
Phone:302-325-9880
Contract Num:SP0450-01-M-LC44
CAGE:56385
============= Composition/Information on Ingredients =============
Name:NON-HAZARDOUS PRODUCT
= Wt:100.
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE PROVIDED BY MFR
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:LOW ORAL AND DERMAL TOXICITY.
PROLONGED OR REPEATED EXPOSURE MAY CAUSE IRRITATION, NAUSEA, AND
VOMITING.
Explanation of Carcinogenicity:THE PRODUCT CONTAINS NO KNOWN
CARCINOGENS. NO SPECIAL WARNING LABELS ARE REQUIRED UNDER OSHA CFR
1910.1200.
Effects of Overexposure:PROLONGED OR REPEATED EXPOSURE MAY CAUSE
IRRITATION, NAUSEA, AND VOMITING.
Medical Cond Aggravated by Exposure:NONE PROVIDED BY MFR
======================= First Aid Measures =======================
First Aid:EYE CONTACT: FLUSH WITH WATER FOR 15 MINUTES. CALL A
PHYSICIAN IF IRRITATION DEVELOPS. SKIN CONTACT: WASH SKIN WITH SOAP
AND WATER. INHALATION: REMOVE TO FRESH AIR. INGESTION: FIRST AID
NOT NORMALLY R EQUIRED, IF UNCOMFORTABLE, CALL PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:=232.2C, 450.F
Autoignition Temp:Autoignition Temp Text:N/E
Lower Limits:NOT ESTABLIS
Upper Limits:NOT ESTABLIS
Extinguishing Media:DRY CHEMICAL, CO2 FOAM, WATER SPRAY.
Fire Fighting Procedures:FIREFIGHTERS SHOULD USE NIOSH/MNSA APPROVED
SELF- CONTAINED BREATHING APPARATUS. USE WATER TO COOL FIRE-EXPOSED
CONTAINERS TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:BURNING MAY PRODUCE IRRITATING/NOXIOUS
FUMES.
================== Accidental Release Measures ==================
Spill Release Procedures:USE ABSORBENT MATERIALS TO SOAK UP FLUID.
Neutralizing Agent:NONE PROVIDED BY MFR
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN CLEAN, DRY AREA.
Other Precautions:NONE PROVIDED BY MFR
============= Exposure Controls/Personal Protection =============
Respiratory Protection:FIRE FIGHTERS SHOULD USE NIOSH/MNSA APPROVED
SELF-CONTAINED BREATHING APPARATUS.
Ventilation:NONE PROVIDED BY MFR. USE IN WELL VENTILATED AREA.
Protective Gloves:CHEMICAL IMPERVIOUS, NOT REQUIRED, BUT RECOMMENDED
FOR PROLONGED EXPOSURE.
Eye Protection:NONE PROVIDED BY MFR
Other Protective Equipment:NONE PROVIDED BY MFR
Work Hygienic Practices:FOR GENERAL PERSONAL HYGIENE, WASH HANDS
THOROUGHLY AFTER HANDLING MATERIAL. AVOID CONTACT WITH SKIN AND
EYES. USE IN WELL VENTILATED AREA.
Supplemental Safety and Health
NONE PROVIDED BY MFR
================== Physical/Chemical Properties ==================
HCC:V5
Boiling Pt:B.P. Text:N.A.
Melt/Freeze Pt:M.P/F.P Text:NONE PROVIDED BY MFR
Decomp Temp:Decomp Text:NONE PROVIDED BY MFR
Vapor Pres:NEGLIGIBLE
Vapor Density:NONE PROVI
Spec Gravity:0.912 (WATER=1)
pH:NONE PROVIDED
Viscosity:71.5 CST @ 100 DEG F
Evaporation Rate & Reference:NONE PROVIDED BY MFR
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER - STRONG SULFUR ODOR.
Percent Volatiles by Volume:NONE PROVIDE
Corrosion Rate:NONE PROVIDED BY MFR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDIZERS.
Stability Condition to Avoid:THIS PRODUCT IS STABLE AND WILL NOT REACT
WITH WATER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:INCINERATE THIS PRODUCT AND ALL ASSOCIATED
WASTES IN A LICENSED FACILITY IN ACCORDANCE WITH FEDERAL, STATE,
AND LOCAL REGULATIONS.
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|