===================== Product Identification =====================
MSDS NAME:HIGH RATE LITHIUM MANGANESE DIOXIDE CELLS/BATTERIES
NIIN:01-455-7946
Status Code:A
MSDS Number: CLPQC
=== Responsible Party ===
Company:ULTRALIFE BATTERIES UK LTD
Address:18 NUFFIELD WAY
City:ABINGDON, UNITED KINGDON
Info Phone Num:01-235-52-0502
Emergency Phone Num:01-235-52-0502
Resp. Party Other MSDS Num.:MSDSLIMN
CAGE:U6734
=== Contractor Identification ===
Company:BATTERY ASSEMBLERS INC
Address:211-4 KNICKERBOCKER AVE
Box:City:BOHEMIA
State:NY
ZIP:11716
Country:US
Phone:407-323-3390/EM:516-567-8855/8278
Contract Num:DAAB07-98-D-R311-0004
CAGE:0B0Y5
Company:ULTRALIFE BATTERIES UK LTD
Address:18 NUFFIELD WAY
Box:City:ABINGDON, UNITED KINGDON
Phone:01-235-52-0502
CAGE:U6734
============= Composition/Information on Ingredients =============
Name:LITHIUM
CAS:7439-93-2
RTECS #:OJ5540000
= Wt:3.
Name:MANGANESE DIOXIDE
CAS:1313-13-9
RTECS #:OP0350000
Minumum % Wt:35.
Maxumum % Wt:40.
OSHA PEL:C5 MG/M3
ACGIH TLV:5 MG/M3
Name:PROPYLENE CARBONATE
CAS:108-32-7
RTECS #:FF9650000
= Wt:6.
Name:1,2-DIMETHOXYETHANE
CAS:110-71-4
RTECS #:KI1451000
= Wt:5.
Name:TETRAHYDROFURAN
CAS:109-99-9
RTECS #:LU5950000
= Wt:5.
OSHA PEL:590 MG/M3;200 PPM
ACGIH TLV:590 MG/M3;200 PPM
ACGIH STEL:737 MG/M3;250 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:LITHIUM PERCHLORATE
CAS:7791-03-9
= Wt:1.
===================== Hazards Identification =====================
Health Hazards Acute and Chronic:BATTERIES ARE HERMETICALLY SEALED, AND
AS SUCH ARE NON-HAZRDOUS UNDER NORMAL USE. BATTERIES SHOULD NOT BE
OPENED OR INCINERATED BECAUSE THEY CONTAIN HAZARDOUS INGREDIENTS
AND CAN BE HARMFUL IF INHALED , INGESTED OR ABSORBED THROUGH SKIN.
INGREDIENTS ARE FLAMMABLE, CORROSIVE AND TOXIC. MAY CAUSE
IRRITATION, BURNS, HEADACHE, DIZZINESS AND NAUSEA.
Effects of Overexposure:HARMFUL BY INGESTION, INHALATION AND SKIN
CONTACT CAUSING HEADACHE, DIZZINESS AND NAUSEA. IRRITATING TO SKIN,
EYES AND RESPIRATORY SYSTEM.
======================= First Aid Measures =======================
First Aid:SHOULD LIQUID ELECTROLYTE COME INTO DIRECT CONTACT WITH THE
SKIN IT SHOULD BE REMOVED BY FLUSING WITH WARM SOAPY WATER. EYES:
FLUSH WITH WATER FOR 15 MIN WHILE KEEPING EYELIDS OPEN. OBTAIN
MEDICAL HEL P. LITHIUM METAL CONTACT: SKIN:REMOVE PARTICLES OF
LITHIUM, FLUSH WITH WATER. IF PARTICLES ARE EMBEDDED, COVER WITH
MINERAL OIL, DO NOT FLUSH WITH WATER, OBTAIN MEDICAL HELP
IMMEDIATELY. EYES: REMOVE PARTICLES IMMDIATELY AND FLUSH WITH
WATER FOR 15 MIN. GET MEDICAL HELP.
===================== Fire Fighting Measures =====================
Extinguishing Media:IN CASE OF FIRE USE A DRY POWDER EXTINGUISHER BASED
ON GRAPHITE (LITH-X) OR OTHER SUITABLE EXTINGUISHERS DESIGNED FOR
ALKALI METAL FIRES.
Fire Fighting Procedures:WATER, CO2, OR HALON EXTINGUISHERS SHOULD NOT
BE USED.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE AND CORROSIVE. REACTS
VIGOROUSLY WITH WATER EMITTING FLAMMABLE GAS. CONTENTS ARE
FLAMMABLE. BATTERY MAY EXPLODE IN FIRE.
================== Accidental Release Measures ==================
Spill Release Procedures:IN THE EVENT OF A CELL LEAKING IT SHOULD BE
CAREFULLY ISOLATED FROM ANY OTHER CELLS AND PLACED INSIDE A
POLYTHENE BAG. DOWTY BATTERIES SHOULD BE CONTACTED FOR ADVICE ON
DISPOSAL. IF LEAKAGE OCCURS FRO M A CELL WHILST CONNECTED TO A
PRINTED CIRCUIT BOARD IT SHOULD BE REMOVED FROM THE BOARD AS SOON
AS POSSIBLE IN ORDER TO AVOID CORROSION.
====================== Handling and Storage ======================
Handling and Storage Precautions:CELLS SHOULD BE STORED IN A WELL
VENTILATED DRY AREA AT TEMPERATURES BELOW 80C. THE OPTIMUM STORAGE
TEMPERATURE FOR MAXIMUM LIFE IS -10C TO +25C. DO NOT ATTEMPT TO
CHARGE OR REVERSE CHARGE CELLS. TO D O SO MAY CAUSE THE CELL TO
VENT OR EXPLODE. DO NOT SHORT CIRCUIT. THIS MAY PRODUCE HIGH
TEMPERATURES
Other Precautions:TERMINALS MUST BE SUITABLY PROTECTED AT ALL TIMES
WHEN NOT CONNECTED TO A CIRCUIT. DO NOT CRUSH, PUNCTURE,OPEN,
DISMANTLE OR OTHERWISE MECHANICALLY INTERFERE WITH OR ABUSE THESE
CELLS. CELLS SHOULD NO T BE CONNECTED TOGETHER TO FORM A BATTERY
WITHOUT THE APPROVAL OF MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Protective Gloves:N/P. PVC/RUBBER WHEN HANDLING LEAKY BATTERIES.
Supplemental Safety and Health
PART NUMBER OF BATTERY PACK (6 CELLS PER PACK) : 138691-1/ 139790-1,
AND P/N FOR EACH CELL: 900722-2 / 900718-1, U2550HCE C CELL.
================== Physical/Chemical Properties ==================
HCC:Z6
Appearance and Odor:6.0 VOLT BATTERY
==================== Disposal Considerations ====================
Waste Disposal Methods:CELLS AND BATTERIES SHOULD BE DISPOSED OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS. DO NOT
DISPOSE OF IN FIRE. PRIOR TO THEIR DISPOSAL CELL TERMINALS SHOULD
BE PROTECTED BY TAPE OR OTHE R SUITABLE MEANS AND BE SEALED IN
POLYTHENE BAGS. CELLS/BATTERIES SHOULD BE FULLY DISCHARGED BEFORE
DISPOSAL.
=================== MSDS Transport Information ===================
Transport Information:CELLS/BATTERIES ARE CLASSIFIED AS UN3090, LITHIUM
BATTERIES, OR UN3091 LITHIUM BATTERIES CONTAINED IN EQUIPMENT. THEY
ARE CLASS 9 MISCELLANEOUS, PACKING GROUP II. MUST COMPLY WITH IATA
PACKING INSTRUC TIONS 903, 912 AND PROVISION A45.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|