===================== Product Identification =====================
MSDS NAME:ETHYL ETHER
NIIN:00-597-5299
MSDS Number: BFGYZ
=== Responsible Party ===
Company:BURDICK & JACKSON LAB,INC. (SEE SUP DATA)
Address:1953 SOUTH HARVEY STREET
City:MUSKEGON
State:MI
ZIP:49442
Info Phone Num:616 726 3171
Emergency Phone Num:312 973 3600 OR 800 424 9300
CAGE:BURDI
=== Contractor Identification ===
Company:BURDICK & JACKSON, INC.
Address:1953 S. HARVEY STREET
Box:City:MUSKEGON
State:MI
ZIP:49442
Country:US
Phone:616-726-3171
CAGE:BURDI
Company:HONEYWELL, BURDICK AND JACKSON
Address:1953 S HARVEY STREET
Box:City:MUSKEGON
State:MI
ZIP:49442-6101
Country:US
Phone:800-368-0050/800-707-4555
CAGE:2H215
============= Composition/Information on Ingredients =============
Name:ETHYL ETHER (SARA III)
CAS:60-29-7
RTECS #:KI5775000
Fraction by Wt: 100%
Other REC Limits:N/K
OSHA PEL:400 PPM/500 STEL
ACGIH TLV:400PPM/500STEL; 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:ETHYL ALCOHOL (ETHANOL)
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 2%
Other REC Limits:N/K
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
Name:2,6-DI-TERT-BUTYL-P-CRESOL
CAS:128-37-0
RTECS #:GO7875000
Fraction by Wt: 1% PPM
Other REC Limits:N/K
OSHA PEL:10 MG/M3
ACGIH TLV:10 MG/M3; 9192
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXP CAN CAUSE HDCH, NAUS, VOMIT,
LOSS OF CONSCIOUS, & IN VERY HIGH CONC, DEATH DUE TO RESP
PARAL.EYE:LIQ & HIGH VAPOR CONC CAN CAUSE IRRIT.SKIN:PRLNG/RTPD
SKIN CONT CAN CAUSE IRRIT & DERMAT THRO UGH DEFAT OF
SKIN.INGESTION:SYMPTOM INFORMATION IS INADEQUATE/UNKNOWN. CONC
IMMED DANGER TO HEALTH:OSHA/NIOSH:19,000 PPM
Explanation of Carcinogenicity:POSITIVE MUTAGEN(RTEC) (MFR).ETHANOL IS
A SUSPECTED CARCINOGEN & TERATOGEN (NIOSH).(MFR)
Effects of Overexposure:ETHYL ETHER IS A MILD EYE & MUCOUS MEMBRANE
IRRITANT, PRIMARY SKIN IRRITANT, & CENTRAL NERVOUS SYSTEM
DEPRESSANT.ACUTE EXPOSURE CAN CAUSE ANESTHETIC EFFECTS SUCH AS
VOMITING, EXCITEMENT, UNCONSCIOUSNE SS, COMA, RESPIRATORY
PARALYSIS, & DEATH.CHRONIC EXPOSURES MAY PRODUCE CENTRAL NERVOUS
SYSTEM DISTURBANCES.
Medical Cond Aggravated by Exposure:PRECLUDE FROM EXPOSURE THOSE
INDIVIDUALS SUSCEPTIBLE TO DERMATITIS.
======================= First Aid Measures =======================
First Aid:INHAL:IMMED RMV TO FRESH AIR.IF NOT BRTHING,ADMIN
MOUTH-TO-MOUTH RESCUE BRTHING.IF NO PULSE ADMIN CPR.CONT MD
IMMED.EYE:RINSE W/COPIOUS AMT H*2O FOR AT LEAST 15 MIN.GET EMER MED
ASST.SKIN:FL THOROUGH FOR AT LEAST 15 MIN.WASH AFFECT SKIN
W/SOAP&H*2O.RMV CONTAM CLTHG & SHOES.WASH CLTHG BFR RE-USE &
DISCARD SHOES.GET EMER MED ASST.INGEST:CALL LCL POISON CONTROL
CENTER FOR ASST.CONT MD IMMED(SUPP DAT)
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:-49 F (-45 C)
Lower Limits:1.85
Upper Limits:48
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM
Fire Fighting Procedures:USE NIOSH/MSHA APVD SCBA & FULL PROT EQPT
.HEAT WILL BUILD PRESS & MAY RUPTURE CLOSED STORAGE CNTNR.COOL
CNTNR W/H*2O SPRAY.TREAT AS FLAMMABLE GAS.
Unusual Fire/Explosion Hazard:EXTM VOLATILE & FLAMMABLE.CAN FORM HEAT
SENS PEROXIDES WHICH MAY EXPLD ON CONC OR EVAP.KEEP AREA COOLED BLW
320F (160C) TO EXTINGUISH AN ETHER FIRE&PVNT REIGNIT
================== Accidental Release Measures ==================
Spill Release Procedures:PROT FROM IGN.WEAR PROT CLTHG & USE APVD RSPTR
EQPT.ABSORB SPILL MATL IN AN ABSORB RECM FOR SOLVENT SPILL & RMV TO
SAFE LOCATION FOR DISPOSAL BY APPROVED METHODS.IF RELEASED TO THE
ENVIRONMENT, COMPLY W/ALL REGULATORY NOTIFICATION REQUIREMENTS.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:ETHYL ETHER SHOULD BE PROT FR TEMP
EXTM & DIR SUNLIGHT.PROPER STORAGE OF ETHYL ETHER MUST BE DETERMINE
BASED ON OTHER MATL STORED & THEIR(SEE OT PREC)
Other Precautions:HAZ & POT CHEM INCOMPATIBILITY.IN GENL,ETHYL ETHER
SHOULD BE STORED IN AN ACCEPT PROT & SECURE FLAMMABLE LIQ STORAGE
ROOM:PERIOD CHECK FOR PEROXIDES IN STORE MATL & PRIOR TO USE,ESP
BFR CONC OR HEAT.G ND & BOND MET CNTNR TO MIN STATIC SPARKS
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . USE APVD RSPTR EQPT. FOLLOW NIOSH & EQPT
MANUFACTURERS RECM TO DETERMINE APPROPRIATE EQPT
(AIR-PURIFYING,AIR-SUPPLIED, OR SELF CONTAINED BREATHING
APPARATUS).
Ventilation:ADEQUATE VENT REQD TO PROT PERS FR EXPSR TO CHEM VAPORS
EXCEED PEL & TO MIN FIRE HAZ.CHOICE OF VENT EQPT,LCL (SUPP DATA)
Protective Gloves:CHEM RESIST:NEOPRENE OR BUNA-N
Eye Protection:CHEM WORK GOGGLES,FACESHLD OPTIONAL FP N
Other Protective Equipment:EMERGENCY EYE WASH FOUNTAINS & SAFETY
SHOWERS SHOULD BE AVAILABLE IN THE VICINITY OF ANY POTENTIAL
EXPOSURE.PROT CLTHG.
Work Hygienic Practices:INDIVIDUALS WHO ARE ACUTELY & SPECIFICALLY
SENSITIVE TO ETHYL ETHER MAY REQUIRE ADDITIONAL PROTECTIVE
EQUIPMENT.
Supplemental Safety and Health
PH & CARC:FP N.HAZ POLY OCCUR:NOT EXPECTED TO OCCUR(MFR).FIRST
AID:NEVER INDUCE VOMIT OR GIVE ANYTHING BY MOUTH TO VICTIM UNCON OR
HAVING CONVULSIONS.VENTILATION:OR GENL, WILL DEPEND ON THE
CONDITIONS OF USE, QUANTITY OF MATL, & OTHER OPERATE
PARAMETERS.CONTAINER SIZE:5 LB CAN
================== Physical/Chemical Properties ==================
HCC:F2
Boiling Pt:B.P. Text:94F/34C
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:442
Vapor Density:2.6
Spec Gravity:0.713
Evaporation Rate & Reference:>10 BUTYL ACETATE=1
Solubility in Water:6.89% AT 20 C
Appearance and Odor:CLEAR, COLORLESS LIQUID WITH A SWEET, PUNGENT ODOR.
Percent Volatiles by Volume:100
Corrosion Rate:
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS & STRONG ACIDS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME, OPEN CONTAINERS,
AND POOR VENTILATION.
Hazardous Decomposition Products:INCOMPL COMB CAN GENERATE CO & OTHER
TOXIC VAPORS.XPL PEROXIDES CAN FORM AFT STAND OR UPON EXP TO
AIR/DIRECT SUNLIGHT.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE & LOCAL REGULATIONS . DISPOSE OF ETHYL ETHER AS AN EPA
HAZARDOUS WASTE. HAZARDOUS WASTE NUMBERS:U117 (IGNITABLE); D001
(IGNITABLE).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|