===================== Product Identification =====================
MSDS NAME:SCOTCH-GRIP(TM) 1711 RUBBER AND GASKET ADH
NIIN:00-598-8065
MSDS Number: BFHPL
=== Responsible Party ===
Company:3M COMPANY
Address:3M CENTER
City:ST. PAUL
State:MN
ZIP:55144-1000
Country:US
Info Phone Num:612-733-1110
Emergency Phone Num:612-733-1110
CAGE:76381
=== Contractor Identification ===
Company:3M MINNESOTA MINING AND MFG CO ADHESIVES SEALERS DIV
Address:3M CTR
Box:City:SAINT PAUL
State:MN
ZIP:55144-1000
Country:US
Phone:800-364-3577/651-737-6501(24 HOURS)
CAGE:04963
Company:MINNESOTA MINING AND MFG CO, DBA 3M
Address:3M CENTER BLDG 224-5S-04
Box:City:SAINT PAUL
State:MN
ZIP:55144-1000
Country:US
Phone:866-556 5712 / 612-733-1110
CAGE:76381
============= Composition/Information on Ingredients =============
Name:CHLOROPRENE POLYMER
Fraction by Wt:
Other REC Limits:
OSHA PEL:
ACGIH TLV:
Name:MAGNESIUM RESINATE
Fraction by Wt:
Other REC Limits:
OSHA PEL:
ACGIH TLV:
Name:ANTIOXIDANT
Fraction by Wt:
Other REC Limits:
OSHA PEL:
ACGIH TLV:
Name:THERMOPLASTIC RESINS
Fraction by Wt:
Other REC Limits:N/D(MFR)
OSHA PEL:
ACGIH TLV:
Name:ZINC OXIDE
CAS:1314-13-2
RTECS #:ZH4810000
Fraction by Wt:
Other REC Limits:N/D
OSHA PEL:15MG/M3 TDUST/5 FUME
ACGIH TLV:10MG/M3 TDUST; 9293
Name:CALCIUM CARBONATE (MARBLE) (LIMESTONE)
CAS:1317-65-3
RTECS #:EV9580000
Fraction by Wt:
Other REC Limits:N/D(MFR)
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9192
Name:PETROLEUM DISTILLATE.CONTAINS 23% N-HEXANE.SEE INGREDIENT
N0 8.
CAS:8030-30-6
Fraction by Wt: 21.0%
Other REC Limits:400(PPM)
OSHA PEL:
ACGIH TLV:
Name:HEXANE (N-HEXANE)
CAS:110-54-3
RTECS #:MN9275000
Fraction by Wt: 7.0%
Other REC Limits:50(PPM)
OSHA PEL:500 PPM
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 33.0%
Other REC Limits:100 PPM
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:ETHYL ALCOHOL (ETHANOL)
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 1.0%
Other REC Limits:
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT:LIQUID IRRITATING TO
EYES.CAN CAUSE TEARING,REDNESS,AND BLURRED VISION.SKIN
CONTACT:ACUTE EXPOSURE IS MIDLY IRRITATING.PROLONGED OR REPEATED
CONTACT WILL PRODUCE DEFATTING AND RESULTANT DE RMATITIS.INHAL:OF
VAPORS AT CONC EXCEEDING THE ESTABLISHED EXPOS LIMITS MAY CAUSE
RESP(SIGN & SYMPTOM OF OVEREXPOSURED).
Effects of Overexposure:HLTH HAZ(ACUTE CHRONIC):SYSTEM IRRITATION.SYMP
OF OVEREXPOS INCLUDE DROWINESS,LIGHT-HEADEDNESS,DIZZY,NAUSEA &
HDCH.RPTD OR EXTREME OVEREXPOSURE TO TOLUENE VAPOR OR N-HEXANE MAY
CAUSE NEVEROUS SYSTEM D AMAGE.INGEST:SWALLOWING MAY CAUSE
GASTROINESTINAL IRRITATION,NAUSEA,DIARRHEA & NERVOUS SYS
IMPAIRMENT.(SEE SUP DATA)
======================= First Aid Measures =======================
First Aid:EYE:FLUSH EYES IMMED W/ PLENTY OF H*20 FOR AT LEAST 15
MIN(CALL PHYS.SKIN:WASH AREA W/ SOAP & H*2O.INHAL:MOVE PERSON TO
FRESH AIR AT ONCE.RESTORE OR SUPPORT BREATH.BREATH DIFFICULT
PERSIST.CALL PH YS.INGEST:DO NOT INDUCE VOMITING.GIVE VICTIM TWO GL
OF MILK OR WATER TO DRINK,CALL PHYS IMMEDIATELY.IF SPONTANEOUS
VOMITING SHOULD OCCUR.LOWER HEAD BETWEEN KNEES TO PREVENT
ASPIRATION INTO LUNGS.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:-14 F;-25.56 C
Lower Limits:1.0
Upper Limits:8.0
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM
Fire Fighting Procedures:FIRE FIGHTERS SHOULD BE EQUIPPED W/ SCBA WHEN
FIGHTING FIRES INVOLING THIS MATERIAL(MFR).USE NIOSH/MSHA APPROVED
SCBA & FULL PROCTIVE EQUIPMENT
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE.OVERHEATED,CLOSED
CONTAINERS ADJACENT TO FIRE COULD EXPLODE DUE TO PRESSURE BUILDUP.
================== Accidental Release Measures ==================
Spill Release Procedures:OBSERVE PRECAUTIONS IN ALL SECTION.EXTINGUISH
ALL IGNITION SOURCES.COLLECT SPILLED MATERIAL,CLEANUP RESIDUE AND
STORE IN CLOSED METAL CONTAINER.(U.S.DEPOT.OF TRANSPORTATION
APPROVED IF WASTE WILL BE S HIPPED)
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT,SPARKS &
FLAME.AVOID CONTACT W/ EYES & SKIN.AVOID PROLONGED BREATH OF
VAPOR.KEEP CONTR CLOSED WHEN NOT IN USE.
Other Precautions:THE VAPORS RELEASED BY THIS PRODUCT CAN BE EASILY
IGNITED.KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIAE FOR
EXPOSURE OF CONCERN
Ventilation:USE ONLY IN AREAS ADEQUATELY VENT W/ ENOUGH AIR MOVEMENT TO
REMOVE VAPORS & PREVENT VAPORS BUILDUP.CONSULT(SEE SUP DATA)
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Work Hygienic Practices:OBSERVE GOOD WORK HYGIENCE PRACTICES
Supplemental Safety and Health
SIGNS & SYMP OF OVEREXPOS:SOLVENT ASPIRATION INTO THE KUNGS AS A RESULT
OF VOMITING MAY CAUSE LUNG DAMAGE.VENT:LOCAL SAFETY/HEALTH
AUTHORITIES IF ADDITIINSAL GUIDANC IS NECESSARY.
================== Physical/Chemical Properties ==================
HCC:F2
Boiling Pt:B.P. Text:140F
Vapor Pres:68F 120 MM
Vapor Density:3.0
Spec Gravity:0.8900
Evaporation Rate & Reference:>/=3.5 ETHER=1
Solubility in Water:SLIGHT
Appearance and Odor:TAN,LOW VISCOSITY LIQUID W/ STRONG SOLVENT ODOR
Percent Volatiles by Volume:61.0%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Hazardous Decomposition Products:THERMAL DECOMPOSITION OR BURNING MAY
PRODUCE CO,CO*2,HCL & OTHER CHLORINATED DECOMPOSITION PRODUCTS.
==================== Disposal Considerations ====================
Waste Disposal Methods:COMMERICAL INCINERATION W/ DESTRUCT & REMOVAL
EFFICIENTCY >=99% OR RECLAMATION IS PREFERRED.INCINERATED,MORE THAN
99% OF HCL IN EXHAUST GAS SHOULD BE REMOVED.DISPOSE IAW LOCAL &
CURRENT EPA REGS. EPA HAZARDOUS WASTE NUMBER D001 (IGNITABLE).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|