===================== Product Identification =====================
MSDS NAME:LACQUER CAMOUFLAGE INSTR BLK 27038 ID78701
NIIN:00-663-9434
MSDS Number: BFKGV
=== Responsible Party ===
Company:PRATT & LAMBERT, INC.
Address:16116 E 13TH ST
Box:2153
City:WICHITA
State:KS
ZIP:67201
Country:US
Preparer's Name:W.A. ELLISON
CAGE:FO127
=== Contractor Identification ===
Company:PRATT & LAMBERT, INC/BUFFALO, NY 14240
Box:22
CAGE:FO127
Company:PRATT AND LAMBERT INC
Address:Box:6027
City:CLEVELAND
State:OH
ZIP:44101-1027
Country:US
Phone:216-566-2902
CAGE:61196
============= Composition/Information on Ingredients =============
Name:ISOBUTYL ACETATE (SARA III)
CAS:110-19-0
RTECS #:AI4025000
Fraction by Wt: 20-30%
OSHA PEL:150 PPM
ACGIH TLV:150 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:ISOBUTYL ALCOHOL (SARA III)
CAS:78-83-1
RTECS #:NP9625000
Fraction by Wt: 5-10%
OSHA PEL:100 PPM
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:PHOSPHORIC ACID 85%
Fraction by Wt: < 0.5%
Name:METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: < 5%
OSHA PEL:200 PPM/300 STEL
ACGIH TLV:200 PPM/300STEL 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:TOLUENE (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 10-20%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Effects of Overexposure:INHALATION: ANESTHETIC. IRRITATION OF NOSE,
THROAT, EYES AND POSSIBLE DIZZINESS AND NAUSEA
======================= First Aid Measures =======================
First Aid:EYE: FLUSH IMMEDIATELY W/LG AMNTS OF WTR FOR 15 MINS.
SKIN: REMOVE CONTAMINATED CLOTHING & WASH
AFFECTED AREA W/WATER. INHAL: REMOVE TO FRESH
AIR.INGST: DO NOT INDUCE VOMITING.
**CONSULT A PHYSICIAN IMMEDIATELY IN ALL CASES**
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:21 F/-6.11
Extinguishing Media:USE NFPA CLASS B EXTINGUISHERS. POLYMER FOAM IS
PERFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SCBA. WATER MAY BE INEFFECTIVE BUT MAY BE
USED TO COOL CLOSED CONTAINERS TOPREVENT PRESS. BUILDUP & POSS.
IGNITION. IF WTR IS USED FOG NOZZLES PERFERRED.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTYL CLOSED & ISOLATED
FROM HEAT,ELEC. EQUIP.,SPARKS, & OPEN FLAME. CLOSED CONTAINERS MAY
EXPLODE WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. REMOVE WITH
INERT ABSORBENT & USE NON SPARKING TOOLS. AVOID CONTAMINATION OF
GROUND WATER OR STREAMS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 120 F. STORE LG
QYTS IN COMPLIANCE W/OSHA 29CFR1910.106. CONTNRS SHOULD BE
BONDEDGROUNDED PROPERLY W/TRANSFERING,POURING TO CONTNR
Other Precautions:DO NOT CUT OR WELD ON EMPTY CONTAINERS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:OUTDOORS/OPEN AREAS USE NIOSH APPROVED
MECHANICAL RESPIRATOR. RESTRICTED AREAS USE NIOSH
CHEMICAL-MECHANICAL FILTERS CONFINED AREAS
USE NIOSH APPROVED AIR SU PPLIED RESPIRATOR OR HOODS
Ventilation:GENERAL DILUTION OR LOCAL EXHAUST
Protective Gloves:SOLVENT IMPERMEABLE
Eye Protection:SAFETY EYEWEAR
Other Protective Equipment:USE PROTECTIVE EQUIPMENT TO PREVENT SKIN
CONTACT.
Supplemental Safety and Health
NK
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:174-700 F
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:73
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ACIDS OR ALKALIS
Stability Condition to Avoid:AVOID FIRES, HEAT, SPARKS, AND HOT
SURFACES
Hazardous Decomposition Products:SMOKE AND OXIDES OF NITROGEN AND
CARBON WHEN BURNED
Conditions to Avoid Polymerization:DO NOT ADD DRIERS OR REACTIVE
CHEMICALS WITHOUT TECHNICAL SUPERVISION.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE, AND
LOCAL REGULATIONS. INCINERATE IN EPA APPROVED FACILITIES. DO NOT
INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|