===================== Product Identification =====================
MSDS NAME:5869
NIIN:00-814-2138
MSDS Number: BFQNG
=== Responsible Party ===
Company:AMPEREX CORP
Address:230 DUFFY AVE
City:HICKSVILLE
State:NY
ZIP:11802
Country:US
CAGE:MO021
=== Contractor Identification ===
Company:AMPEREX CORP
Address:230 DUFFY AVE
Box:City:HICKSVILLE
State:NY
ZIP:11802
Country:US
CAGE:MO021
Company:AMPEREX ELECTRONIC CORP
Address:230 DUFFY AVE
Box:City:HICKSVILLE
State:NY
ZIP:11802
Country:US
CAGE:73445
============= Composition/Information on Ingredients =============
Name:MERCURY (SARA III)
CAS:7439-97-6
RTECS #:OV4550000
OSHA PEL:S, C, 0.1 MG/M3
ACGIH TLV:S, 0.05 MG/M3; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
===================== Hazards Identification =====================
Effects of Overexposure:CNTCT DOCTR;INHAL:SORE
THROAT,HEADACHE,NAUSEA;SKIN:REDNESS;EYES:IRRITATION;INGEST:VOMIT,DI
ARRHEA
======================= First Aid Measures =======================
First Aid:INHAL:FRESH AIR,REST;SKIN:REMOVE CONTAMIN.CLOTHES,RINSE SKIN
W/PLENTY OF WATER OR SHOWER & WASH SKIN W/WATER & SOAP;EYES:RINSE
WITH PLENTY OF WATER;INGEST:GASTRIC LAVAGE-5% SODIUM FORMALDEHYDE
SULFOXY LATE SOLN.,THEN 2% SODIUM (SEE SUPP DATA)
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:MERCURY IS NOT COMBUSTIBLE.
Unusual Fire/Explosion Hazard:YIELDS EXPLOSV.SOLID ON PROLONGED CONTACT
W/AMMONIA,AMINES,ACETYLENE (CMPDS SENSITVE-MECH SHOCK)
================== Accidental Release Measures ==================
Spill Release Procedures:CLEAN-UP IMMED.,USE SUCTION PUMP & ASPIRATOR
BOTTLE W/LONG CAPILLARY TUBE; IN UNACCESSIBLE AREA,TREAT W/CALCIUM
POLYSULFIDE & EXCESS SULFUR;ZINC OR COPPER POWDER CAN ALSO BE USED
OR SPECIAL ABSORBENT - COLLECT CAREFULLY.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP IN COOL PLACE WITH VENTILATION
ALONG FLOOR;DONOT HANDLE WITH BARE HAND OR SKIN
Other Precautions:PERIODIC MEDICAL EXAM.RECOMMENDED,DEPENDING UPON
DEGREE OF EXPOSURE;INSPECT ROOMS WHERE MERCURY IS HANDLED REGULARLY
WITH AID OF SPECIAL EQUIPMENT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:SELF-CNTND BRTHNG APPARAT.OR RESPIRATOR
W/MERCURY CARTRIDGE.
Ventilation:LOCAL EXHAUST OR BREATHING PROTECTION;VENTIL ALONG FLOOR
Protective Gloves:RUBBER
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:PLASTIC COATED CLOTH GLOVES ACCEPT;LAB COAT
Supplemental Safety and Health
(EMERG CONTD) BICARBONATE,THEN LV 250 CC OF 5% SOLN.IN
STOMACH;STARCH-RETENTION ENEMAS FOR DIARRHEA;ANTIDOTE:DIMERCAPROL,
4 MG/KG BODY WT.NOT MORE THAN 300 MG/DOSE IN 4 HR-CALL DOCTOR!!
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:680F/357C
Vapor Pres:<.1
Vapor Density:7.0
Spec Gravity:13.6
Solubility in Water:NONE
Appearance and Odor:SILVER-WHITE METALLIC LIQUID OR LUSTRE; NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
MOST METALS-FORMS AMALGAMS;AMMONIA;AMINES,ACETYLENE,BROMINE
Stability Condition to Avoid:SITUATIONS WHERE THERMOMETER BREAKS OR
MERCURY SPILLS
Hazardous Decomposition Products:MERCURY VAPORS GIVEN OFF MORE RAPIDLY
AS TEMPERATURE INCREAS
==================== Disposal Considerations ====================
Waste Disposal Methods:PLACE MERCURY IN A TIGHTLY,STOPPERED
BOTTLE;DONOT ALLOW ITEM(MERCURY) TO CONTAMINATE AIR OR WATER;WEAR
RUBBER GLOVES,LABORATORY COAT.OBSERVE FEDERAL,STATE,AND LOCAL
DISPOSAL REGULATIONS;DISTILL OR RET URN TO MANUFACTURER FOR
RECYCLE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|