===================== Product Identification =====================
MSDS NAME:GULF TS-864-68 HYDRAULIC OIL
NIIN:00-966-8832
MSDS Number: BFZXT
=== Responsible Party ===
Company:CHEVRON USA,INC.
Emergency Phone Num:(415)233-3737
CAGE:81230
=== Contractor Identification ===
Company:CHEVRON PRODUCTS COMPANY LUBRICANTS AND SPECIALTY PRODUCTS
Address:6001 BOLLINGER CANYON RD
Box:City:SAN RAMON
State:CA
ZIP:94583
Country:US
Phone:800-414-6737 / 800-582-3835
CAGE:81230
Company:CHEVRON RESEARCH CO
Address:576 STANDARD AVE
Box:City:RICHMOND
State:CA
ZIP:94804
Country:US
Phone:510-237-4411
CAGE:96004
============= Composition/Information on Ingredients =============
Name:HIGHLY REFINED BASE OILS,CAS#64742-65-0
Fraction by Wt: >99%.
ACGIH TLV:5MG/CUM (MFR)
Name:ADDITIVES INCLUDING POUR DEPRESSANT,DEFOAMER,ANTIRUST
AGENT,AND ANTIOXIDANT.
Fraction by Wt: <1%.
===================== Hazards Identification =====================
Effects of Overexposure:EYE/SKIN:IRR;INH:IRR,NASAL DISCH,NOSEBLEED,SORE
THROAT,COUGH,BRONCHIT,PULM.EDEMA,DIFFICULT BREATHING
======================= First Aid Measures =======================
Eyes:FLUSH W/WTR 15MIN W/EYELID OPEN.SEE DR;SKIN:WASH
W/SOAP&WTR.LAUNDR.CONTAM.CLOTHING;INH:MOVE TO FRESH AIR.SEE
DR;ING;GIVE WTR/MILK.CONSULT DR. BEFORE INDUCE VOMIT.TAKE
PERSON&PRODUCT CONT.TO DR.IM M.
===================== Fire Fighting Measures =====================
Flash Point:525F,274C,COC
Extinguishing Media:CO*2, FOAM, DRY CHEM & H*2O FOG.
Fire Fighting Procedures:WEAR SCBA & PROPER PROTECTIVE EQUIPM.IN
CONFINED AREAS.
Unusual Fire/Explosion Hazard:NONE SPECIFIED.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE IGNITION SOURCES,VENTILATE AREA
WELL.ABSORB WITH VERMICULITE OR OTHER MATERIALS, SUCH AS
SAWDUST,RAGS,PAPER & PLACE IN CLOSED CONTAINER. USE NON SPARKING
TOOLS. WEAR PROPER PROTECTIVE EQUIPMENT DURING CLEAN UP.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL,DRY WELL VENTED LOW FIRE
RISK AREA. PROTECT FROM HEAT,SHOCK,FRICTION. KEEP CONTAINERS
CLOSED.
Other Precautions:DO NOT WELD,HEAT OR DRILL CONTAINER.RESIDUE MAY
IGNITE W/EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY.-CAUTION!DO NOT
USE PRESSURE TO EMPTY DRUM OR EXPLOSION MAY RESULT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPVD RESP.IF TLV EXCEEDED.
Ventilation:PROVIDE MECHAN(GEN/LOCAL EXHAUST)VENT TO MAINTN
| |