===================== Product Identification =====================
MSDS NAME:DEGLAZING SOLVENT,83-7-78001,83-4-8880-04
NIIN:01-073-0659
MSDS Number: BGKMN
=== Responsible Party ===
Company:MULTIGRAPHICS
Address:1800 W CENTRAL ROAD
City:MT.PROSPECT
State:IL
ZIP:60056-2293
Country:US
Info Phone Num:312-870-5121
Emergency Phone Num:312-870-5121 (DAY) 398-1900 (NIGHT)
CAGE:09177
=== Contractor Identification ===
Company:AM MULTIGRAPHICS DIV OF AM INTL INC
Address:431 LAKEVIEW CT
Box:City:MOUNT PROSPECT
State:IL
ZIP:60056-6048
Country:US
Phone:847-375-1700
CAGE:09177
============= Composition/Information on Ingredients =============
Name:METHYLENE CHLORIDE (SARA III)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 100%
Other REC Limits:100 PPM
OSHA PEL:500 PPM/C,1000; Z2
ACGIH TLV:50 PPM, A2; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:EXTREME PAIN IF SPLASHED IN EYES.
SKIN:PROLONGED CONTACT WILL DEFAT SKIN & MAY CAUSE
IRRITATION/DERMATITIS. INHALATION:STRONG NARCOTIC EFFECT.
INGESTION:STOMACH DISCOMFORT, CAN CAUSE KIDNEY DAMAGE . TARGET
ORGAN:SKIN,CNS, EYES, CVS, KIDNEYS.
Explanation of Carcinogenicity:FOUND TO BE CARCINOGENIC IN SOME LAB
ANIMALS (MFR).
Effects of Overexposure:SEE HEALTH HAZARD DATA .
Medical Cond Aggravated by Exposure:NONE
======================= First Aid Measures =======================
Eyes:IMME FLUSH W/LGE AMTS OF WTR FOR AT LEAST 15 MIN .
SKIN:WASH W/SOAP & WTR. INHALATION:REMOVE TO FRESH AIR. SUPPORT
BREATHING (GIVE O*2/ARTIFICIAL RESPIRATION). INGESTION:DO NOT
INDUCE VOMITING, GIVE MILK/USP MINERAL OIL, TAKE TO HOSPITAL
EMERGENCY ROOM FOR FURTHER TREATMENT.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:N/APPLICABLE.
Fire Fighting Procedures:WEAR PRESSURE DEMAND SELF-CONTAINED BREATHING
APPARATUS & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL SPILL:WIPE W/RAGS/TOWELS. LARGE
SPILL:WEAR SUITABLE MASK-EVAPORATES RAPIDLY.
Neutralizing Agent:N/K
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL PLACE.
Other Precautions:READ & FOLLOW DIRECTONS ON LABEL. DO NOT REUSE
CONTAINER.NO SMOKNG IN AREA OF USE.DO NOT USE IN GEN VICINITY OF
ARC WELDNG,OPEN FLAMES/HOT SURFACE.HEAT &/UV RADIATION MAY CAUSE
THE FORMATION OF HCL &/ PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IN HIGH VAPOR AREA, USE WILSON #1221 RESPIRATOR
W/R21 FILTER (MFR). NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCENRN .
Ventilation:LOCAL EXHST IF GEN VENT CANNOT KEEP VAPORS BELOW 50% OF
TLV.
Protective Gloves:POLYVINYL ALCHL
Eye Protection:CHEMICAL WORKER GOGGLES .
Other Protective Equipment:NEOPRENE OR POLYETHYLENE GLOVES, APRON TO
PREVENT ABSORPTION ONTO CLOTHING.
Work Hygienic Practices:N/K
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:T4
Boiling Pt:B.P. Text:104F,40C
Melt/Freeze Pt:M.P/F.P Text:N/K
Vapor Pres:380
Vapor Density:2.93
Spec Gravity:N/K
Evaporation Rate & Reference:N/K
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR SOLVENT, DISTINCTIVE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:WILL DISSOLVE PAINTS & MANY SYNTHETIC
FIBERS.
Hazardous Decomposition Products:HCL, PHOSGENE .
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL AS HAZARDOUS WASTE PER EPA REGULATIONS
(MFR). DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE & FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|